Experimental analysis of air-multiple pcm heat exchanger in evaporative cooling systems for supply air temperature stabilization

被引:5
|
作者
Kareem, Bashir Eskander [1 ]
Adham, Ahmed Mohammed [1 ]
Yaqob, Banipal Nanno [1 ]
机构
[1] Erbil Polytech Univ, Erbil Tech Engn Coll, Dept Tech Mech & Energy Engn, Erbil, Iraq
来源
JOURNAL OF BUILDING ENGINEERING | 2024年 / 82卷
关键词
Air to multiple PCM heat exchanger; Evaporative cooling system; Thermal comfort; PCM-RT21; PCM-RT25; STORAGE; PERFORMANCE; BUILDINGS; DESICCANT; CLIMATE; DRY; HOT;
D O I
10.1016/j.jobe.2023.108269
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The free cooling system is a highly efficient solution that effectively regulates indoor temperature when the ambient air temperature fluctuates within the thermal comfort range. Compared to traditional cooling systems, the evaporative cooling system excels in cost-effectiveness and has exceptional efficiency in hot and dry climates. However, the system's performance is significantly influenced by the environment, leading to fluctuations in the outlet temperatures of the evaporative cooler. A novel approach to integrating thermal energy storage with an evaporative cooling system has been studied to achieve free cooling and stabilize the system's supply air temperature to address this challenge. The evaporative cooler's design, construction, and experimental testing have been carried out in highly challenging hot and dry environments. The utilization of phase change materials (RT21HC and RT25HC) as a thermal energy storage system has been implemented. Incorporating phase change materials has notably improved the stability of the outlet air temperature from the evaporative cooling system. Furthermore, the outlet air temperature from the system exhibited consistent fluctuations within the range of 21-25 degrees C, requiring a significant amount of energy absorption and release to exceed these temperature thresholds. The findings demonstrate that the proposed system effectively reduces and shifts peak load to off-peak hours. Moreover, thermal energy storage can deliver free cooling during the spring and autumn. However, integrating the PAHX into an evaporative cooling system becomes crucial in regions characterized by extremely hot summer seasons. The maximum deviation between numerical and experimental results is 4 %.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Experimental study on air cooling by spray in the upstream flow of a heat exchanger
    Tissot, J.
    Boulet, P.
    Labergue, A.
    Castanet, G.
    Trinquet, F.
    Fournaison, L.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2012, 60 : 23 - 31
  • [22] EXPERIMENTAL ANALYSIS ON A NOVEL AIR HEAT EXCHANGER CONTAINING PCM (PHASE CHANGE MATERIAL) IN A COLD ROOM
    Copertaro, Benedetta
    Fioretti, Roberto
    Principi, Paolo
    11TH IIR CONFERENCE ON PHASE CHANGE MATERIALS AND SLURRIES FOR REFRIGERATION AND AIR CONDITIONING, 2016, : 142 - 150
  • [23] Performance analysis of an improved PCM-to-air heat exchanger for building envelope applications - An experimental study
    Dardir, Mohamed
    Roccamena, Letizia
    El Mankibi, Mohamed
    Haghighat, Fariborz
    SOLAR ENERGY, 2020, 199 : 704 - 720
  • [24] Experimental investigation of stabilization of flowing water temperature with a water-PCM heat exchanger
    Charvat, Pavel
    Stetina, Josef
    Pech, Ondrej
    Klimes, Lubomir
    Ostry, Milan
    EFM13 - EXPERIMENTAL FLUID MECHANICS 2013, 2014, 67
  • [25] Experimental assessment of a PCM to air heat exchanger storage system for building ventilation application
    Labat, M.
    Virgone, J.
    David, D.
    Kuznik, F.
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 375 - 382
  • [26] STUDY OF HEAT TRANSFER AND PRESSURE DROP CHARACTERISTICS OF AIR HEAT EXCHANGER USING PCM FOR FREE COOLING APPLICATIONS
    Kalaiselvam, Sivakumar
    Sureshkumar, Kanchipuram R.
    Sriram, Vijeykishoor
    THERMAL SCIENCE, 2016, 20 (05): : 1543 - 1554
  • [27] Performance evaluation and economic analysis of integrated earth-air-tunnel heat exchanger-evaporative cooling system
    Bansal, Vikas
    Misra, Rohit
    Das Agrawal, Ghanshyam
    Mathur, Jyotirmay
    ENERGY AND BUILDINGS, 2012, 55 : 102 - 108
  • [28] Numerical analysis of an air-to-air heat pipe heat exchanger and comparison with experimental data
    Martin, Kerim
    Boran, Kurtuluş
    International Journal of Ambient Energy, 2022, 43 (01): : 8592 - 8601
  • [29] Experimental study on the performance of a new encapsulation panel for PCM's to be used in the PCM-Air heat exchanger
    Santos, Thiago
    Kolokotroni, Maria
    Hopper, Nick
    Yearley, Kevin
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND RESOURCE USE IN FOOD CHAINS INCLUDING WORKSHOP ON ENERGY RECOVERY CONVERSION AND MANAGEMENT;ICSEF 2018, 2019, 161 : 352 - 359
  • [30] EVAPORATIVE COOLERS OF WATER AND AIR FOR COOLING SYSTEMS. ANALYSIS AND PERSPECTIVES
    Chen, G. M.
    Doroshenko, A. V.
    Shestopalov, K. O.
    Khliyeva, O. Y.
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 883 - 890