Frequency Down-Converted and Sensitivity Enhanced Fiber Optic Sensing System Based on Multi-Passband Microwave Photonic Filter by Cascaded Fiber Optic Interferometers

被引:2
|
作者
Xie, Tongtong [1 ]
Wang, Haoran [1 ]
Liu, Shiwei [1 ]
Dai, Weiyu [1 ]
Xu, Zuowei [2 ]
Chen, Hao [3 ]
Fu, Hongyan [1 ]
机构
[1] Xiamen Univ, Natl Model Microelect Coll, Sch Elect Sci & Engn, Dept Elect Engn, Xiamen 36100, Peoples R China
[2] Hubei Univ Automot Technol, Coll Mech Engn, Shiyan 442002, Peoples R China
[3] Zhejiang Normal Univ, Hangzhou Inst Adv Studies, Hangzhou 311231, Peoples R China
基金
中国国家自然科学基金;
关键词
Interferometers; Sensors; Optical fibers; Passband; Optical fiber sensors; Sensitivity; Optical interferometry; Fiber optic sensing system; frequency down-converted; multi-passband microwave photonic filter (MPF); REFRACTIVE-INDEX SENSOR; INTERROGATION TECHNIQUE;
D O I
10.1109/JLT.2023.3307826
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We propose and experimentally demonstrate a frequency down-converted and sensitivity enhanced fiber optic sensing technique based on a multi-passband microwave photonic filter (MPF) employing two cascaded fiber optic interferometers and dispersive medium. The frequency shift of the passband centered at high frequency where the sensing element is related can be down-converted to the frequency shift of low-frequency passband and enjoying narrower 3 dB bandwidth. And even greater frequency shift of passband located at low frequency have been achieved in our proposed fiber optic sensing system. Two interferometers, the Sagnac interferometer (SI), and the Mach-Zehnder interferometer (MZI) are used as a demonstration and the proof-of-concept experiments of temperature measurement are demonstrated, which show that our proposed fiber optic sensing system can down-converted the monitoring passband of SI based MPF from 687 MHz to 437 MHz, while enjoying narrower 3 dB bandwidth and maintaining the same sensitivity (0.81 MHz/degrees C) that of at 687 MHz, and thus bring convenience to detection. In addition, when taking the SI and MZI both as sensing elements, enhanced and adjustable sensitivity of sensing system can be achieved by adjusting the sensing fiber length of MZI. In our experiment, we have achieved enhanced and tailorable sensitivity from 0.81 MHz/degrees C to 8.44 MHz/degrees C, by monitoring the MPF's passband centered at low frequency of 437 MHz, which is about 1.59-16.55 times of the SI based single passband MPF centered at the similar frequency (446 MHz). Lower frequency and higher sensitivity can be obtained by designing the parameters of the fiber optic interferometers, which provides a powerful tool for high sensitivity, high-resolution, and low-cost fiber optic interferometer-based sensor systems.
引用
收藏
页码:477 / 484
页数:8
相关论文
共 50 条
  • [31] Fiber-optic Michelson-Gires-Turnois Interferometer based multifunctional optical filter for microwave photonic applications
    Madamopoulos, Nicholas
    2015 INTERNATIONAL TOPICAL MEETING ON MICROWAVE PHOTONICS (MWP), 2015,
  • [32] X-band Microwave Photonic Filter Using Switch-based Fiber-Optic Delay Lines
    Jung, Byung-Min
    CURRENT OPTICS AND PHOTONICS, 2018, 2 (01) : 34 - 38
  • [33] Sensitivity Enhanced Fiber-Optic Hydrogen Sensor Based on Vernier Effect of Polymer-Air Cascaded FPI
    Liu, Yinggang
    Zhou, Rui
    Xu, Xinyi
    Li, Rui
    Li, Fei
    IEEE SENSORS JOURNAL, 2025, 25 (06) : 9626 - 9632
  • [34] Multi-Point Fiber Optic Displacement Sensing System Based on Cavity Length Detection
    Wang, Fang
    Qin, Xiaozhi
    Zhao, Xinyi
    Yuan, Qiulin
    Liu, Yunqi
    Huang, Yongguang
    Wang, Xu
    Liu, Yufang
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2025, 43 (03) : 1469 - 1478
  • [35] Sensitivity enhanced fiber optic hydrophone based on an extrinsic Fabry-Perot interferometer for low-frequency underwater acoustic sensing
    Xiong, Wanze
    Shu, Qian
    Lu, Ping
    Zhang, Wanjin
    Qu, Zhiyuan
    Liu, Deming
    Zhang, Jiangshan
    OPTICS EXPRESS, 2022, 30 (06) : 9307 - 9320
  • [36] Multi-parameter fiber optic sensing setup based on spectral-overlap using Fabry-Perot Interferometers
    Herrera-Piad, L. A.
    Jauregui-Vazquez, D.
    Rojas Laguna, R.
    Estudillo-Ayala, J. M.
    Lopez-Dieguez, Y.
    Sierra-Hernandez, J. M.
    Filoteo Razo, J. D.
    Hernandez-Garcia, J. C.
    PHYSICS AND SIMULATION OF OPTOELECTRONIC DEVICES XXV, 2017, 10098
  • [37] Fiber-optic sensing scheme based on high-order Stimulated Brillouin scattering in a fiber ring and frequency down-conversion
    Yun, Jin
    Cai, Xun
    Xiang, Zhuowei
    Chen, Xinying
    Fu, Hongyan
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2020, 62 (12) : 4021 - 4026
  • [38] Comb Filter-Based Fiber-Optic Methane Sensor System With Mitigation of Cross Gas Sensitivity
    Liu, Duan
    Fu, Songnian
    Tang, Ming
    Shum, Perry
    Liu, Deming
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2012, 30 (19) : 3103 - 3109
  • [39] High Frequency Sensing Interrogation System Using Fiber Bragg Grating Based Microwave Photonic Filtering
    Fu, Hongyan
    Zhang, Wei
    Mou, Chengbo
    Shu, Xuewen
    Zhang, Lin
    He, Sailing
    Bennion, Ian
    OFC: 2009 CONFERENCE ON OPTICAL FIBER COMMUNICATION, VOLS 1-5, 2009, : 285 - +
  • [40] Development of low frequency and high sensitivity fiber optic accelerometer based on multi-stage flexure hinges
    Li, Huidong
    Gao, Hong
    Fan, Wei
    Zhou, Rui
    Qiao, Xueguang
    OPTICAL FIBER TECHNOLOGY, 2022, 73