Frequency Down-Converted and Sensitivity Enhanced Fiber Optic Sensing System Based on Multi-Passband Microwave Photonic Filter by Cascaded Fiber Optic Interferometers

被引:2
|
作者
Xie, Tongtong [1 ]
Wang, Haoran [1 ]
Liu, Shiwei [1 ]
Dai, Weiyu [1 ]
Xu, Zuowei [2 ]
Chen, Hao [3 ]
Fu, Hongyan [1 ]
机构
[1] Xiamen Univ, Natl Model Microelect Coll, Sch Elect Sci & Engn, Dept Elect Engn, Xiamen 36100, Peoples R China
[2] Hubei Univ Automot Technol, Coll Mech Engn, Shiyan 442002, Peoples R China
[3] Zhejiang Normal Univ, Hangzhou Inst Adv Studies, Hangzhou 311231, Peoples R China
基金
中国国家自然科学基金;
关键词
Interferometers; Sensors; Optical fibers; Passband; Optical fiber sensors; Sensitivity; Optical interferometry; Fiber optic sensing system; frequency down-converted; multi-passband microwave photonic filter (MPF); REFRACTIVE-INDEX SENSOR; INTERROGATION TECHNIQUE;
D O I
10.1109/JLT.2023.3307826
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We propose and experimentally demonstrate a frequency down-converted and sensitivity enhanced fiber optic sensing technique based on a multi-passband microwave photonic filter (MPF) employing two cascaded fiber optic interferometers and dispersive medium. The frequency shift of the passband centered at high frequency where the sensing element is related can be down-converted to the frequency shift of low-frequency passband and enjoying narrower 3 dB bandwidth. And even greater frequency shift of passband located at low frequency have been achieved in our proposed fiber optic sensing system. Two interferometers, the Sagnac interferometer (SI), and the Mach-Zehnder interferometer (MZI) are used as a demonstration and the proof-of-concept experiments of temperature measurement are demonstrated, which show that our proposed fiber optic sensing system can down-converted the monitoring passband of SI based MPF from 687 MHz to 437 MHz, while enjoying narrower 3 dB bandwidth and maintaining the same sensitivity (0.81 MHz/degrees C) that of at 687 MHz, and thus bring convenience to detection. In addition, when taking the SI and MZI both as sensing elements, enhanced and adjustable sensitivity of sensing system can be achieved by adjusting the sensing fiber length of MZI. In our experiment, we have achieved enhanced and tailorable sensitivity from 0.81 MHz/degrees C to 8.44 MHz/degrees C, by monitoring the MPF's passband centered at low frequency of 437 MHz, which is about 1.59-16.55 times of the SI based single passband MPF centered at the similar frequency (446 MHz). Lower frequency and higher sensitivity can be obtained by designing the parameters of the fiber optic interferometers, which provides a powerful tool for high sensitivity, high-resolution, and low-cost fiber optic interferometer-based sensor systems.
引用
收藏
页码:477 / 484
页数:8
相关论文
共 8 条
  • [1] Temperature-Insensitive Fiber-Optic Refractive Index Sensing System With High Sensitivity by Using EFPI-Based Microwave Photonic Filter
    Zheng, Shichen
    Rao, Weiying
    Cai, Xun
    Wu, Mengyuan
    Xie, Tongtong
    Wang, Haoran
    Fu, Hongyan
    IEEE SENSORS JOURNAL, 2024, 24 (03) : 2799 - 2806
  • [2] Sensitivity-Enhanced Fiber-Optic Sensor in a Microwave Photonics Fiber Loop Ringdown System
    Zhu, Chen
    Zhuang, Yiyang
    Huang, Jie
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2022, 40 (16) : 5768 - 5774
  • [3] Sensitivity Enhanced Fiber-Optic Hydrogen Sensor Based on Vernier Effect of Polymer-Air Cascaded FPI
    Liu, Yinggang
    Zhou, Rui
    Xu, Xinyi
    Li, Rui
    Li, Fei
    IEEE SENSORS JOURNAL, 2025, 25 (06) : 9626 - 9632
  • [4] Sensitivity enhanced fiber sensor based on a fiber ring microwave photonic filter with the Vernier effect
    Xu, Zuowei
    Shu, Xuewen
    Fu, Hongyan
    OPTICS EXPRESS, 2017, 25 (18): : 21559 - 21566
  • [5] Multi-Point Fiber Optic Displacement Sensing System Based on Cavity Length Detection
    Wang, Fang
    Qin, Xiaozhi
    Zhao, Xinyi
    Yuan, Qiulin
    Liu, Yunqi
    Huang, Yongguang
    Wang, Xu
    Liu, Yufang
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2025, 43 (03) : 1469 - 1478
  • [6] Microwave Photonic Interrogation of a High-Speed and High-Resolution Temperature Sensor Based on Cascaded Fiber-Optic Sagnac Loops
    Wang, Guangying
    Liao, Baoliang
    Cao, Yuan
    Feng, Xinhuan
    Guan, Bai Ou
    Yao, Jianping
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (12) : 4041 - 4048
  • [7] Fiber-optic Axial Strain Sensing Based on Multi-longitudinal Mode Beat Frequency with Vernier Effect
    Tian, Xiaozhong
    Shen, Chanchan
    Qin, Jingping
    Fu, Xinya
    Wang, Heng
    Liang, Lanju
    ACTA PHOTONICA SINICA, 2024, 53 (12)
  • [8] High-Resolution and Extended-Range Fiber Bragg Grating Sensing System Based on a Microwave Photonic Filter with Period-breaking Interrogation Method
    Xie, Tongtong
    Zhuang, Yi
    Zhou, Jing
    Liu, Shiwei
    Wang, Haoran
    Xu, Zuowei
    Chen, Hao
    Fu, Hongyan