Lower Fatigue in the Eccentric than the Concentric Phase of a Bench Press Set Executed with Maximum Velocity to Failure Against Both Heavy and Light Loads

被引:6
|
作者
Tsoukos, Athanasios [1 ]
Bogdanis, Gregory C. [1 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Phys Educ & Sport Sci, Athens, Greece
关键词
velocity loss; electromyographic activity; velocity-based training; ELECTROMYOGRAPHIC ACTIVITY; MUSCLE ACTIVATION; PERFORMANCE; KINEMATICS; POTENTIATION; FLEXION; REQUIRE; FORCE;
D O I
10.5114/jhk/168792
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
We examined changes in barbell velocity and surface electromyographic activity (sEMG) during the concentric (CON) and eccentric (ECC) phases of a bench press set. Ten men executed a set to instant exhaustion as fast as possible, against a low (40% 1-RM) and a heavy load (80% 1-RM), one week apart. The reduction in mean barbell velocity was lower in the ECC compared with the CON phase for both loads (40%1-RM: ECC: -36 +/- 21% vs. CON: -63 +/- 14%, p < 0.001; 80%1-RM: ECC: -26 +/- 15% vs. CON: -59 +/- 9%, p < 0.001). Under both loading conditions, sEMG activity of the pectoralis major increased in the last compared to the first repetitions only in the CON phase (by 48.6% and 24.8%, p < 0.01, in the 40% and 80%1-RM, respectively). Similarly, triceps brachii sEMG increased by 15.7% (p = 0.02) and by 21.0% (p < 0.001) during the CON phase in the 40% and 80%1-RM conditions, respectively. However, during the ECC phase, sEMG remained unchanged in the last part of the set for both muscles and loads except for 80%1-RM in the pectoralis major muscle. It was concluded that fatigue measured by velocity loss was lower during the ECC than the CON phase of the bench press movement, when the exercise was performed with maximum velocity to failure, irrespective of the load. sEMG was lower in the ECC than the CON phase for all loads, and increased at the end of the set only during the CON phase, while it remained relatively unchanged in the ECC phase, with the exception of the pectoralis muscle when the load was heavier.
引用
收藏
页码:119 / 129
页数:11
相关论文
共 2 条
  • [1] Eccentric Versus Concentric Velocity And Electromyographic Activity In The Bench Press Exercise Against Different Loads
    Bogdanis, Gregory C.
    Tsoukos, Athanasios
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 192 - 192
  • [2] Changes in EMG and movement velocity during a set to failure against different loads in the bench press exercise
    Tsoukos, Athanasios
    Brown, Lee E.
    Terzis, Gerasimos
    Wilk, Michal
    Zajac, Adam
    Bogdanis, Gregory C.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2021, 31 (11) : 2071 - 2082