Systemic observation and measurement of microgap formation in dental implant-abutment connection interface under fatigue

被引:0
|
作者
Mercan, Cigdem [2 ]
Bulutsuz, Asli Gunay [1 ]
Katiboglu, Ahmet Bulent [3 ]
机构
[1] Yildiz Tech Univ, TR-34349 Istanbul, Turkiye
[2] Istanbul Univ, Dent Fac, Istanbul, Turkiye
[3] Atlas Univ, Istanbul, Turkiye
关键词
microgap; fatigue test; experimental design; dental implant-abutment interface; measurement; IN-VITRO EVALUATION; BACTERIAL-COLONIZATION; STRESS-DISTRIBUTION; MICROBIAL LEAKAGE; 2-STAGE IMPLANTS; MARGINAL FIT; DIAMETER; LOAD; INFLAMMATION; MICROMOTION;
D O I
10.1515/mt-2023-0071
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Today, a variety of implant designs with different attachment types are widely used in dental implant systems to eliminate connection problems. However, there are still design issues that can significantly affect the long-term success of dental implants. One of these problems is the formation of a microgap in the abutment-implant interface, which can lead to abutment screw loosening, screw fracture, and abutment fracture under masticatory loading. In this in vitro study, the effects of gingival height, dental implant diameter, and abutment type (solid, digital, and ball) on microgap formation were observed after repetitive fatigue tests using an experimental design. After the tests, the optimal design factors were determined to minimize microgap formation. According to the results of the experimental design, the abutment type was found to be the most influential parameter on microgap formation. An implant diameter of 4.1 mm, the smallest gingival height of 0.5 mm, and a digital attachment combination were identified as the optimal design parameters based on the statistical approach (R-2 = 85.3 %).
引用
收藏
页码:1679 / 1685
页数:7
相关论文
共 50 条
  • [1] Implant-abutment connections: influence of the design on the microgap and their fatigue and fracture behavior of dental implants
    Gil, F. J.
    Herrero-Climent, M.
    Lazaro, P.
    Rios, J. V.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2014, 25 (07) : 1825 - 1830
  • [2] Bacterial Leakage and Microgap along Implant-Abutment Connection in Three Different Implant Systems
    Bajoghli, Farshad
    Amjadi, Mehrak
    Akouchekian, Mohadese
    Narimani, Tahmineh
    INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2016, 7 (04): : 1284 - 1290
  • [3] Histology of a dental implant with a platform switched implant-abutment connection
    Degidi, Marco
    Perrotti, Vittoria
    Piattelli, Adriano
    Shibli, Jamil A.
    Iezzi, Giovanna
    JOURNAL OF OSSEOINTEGRATION, 2011, 3 (03) : 56 - 60
  • [4] Influence of the Use of Transepithelial Abutments vs. Titanium Base Abutments on Microgap Formation at the Dental Implant-Abutment Interface: An In Vitro Study
    Cascos, Rocio
    Celemin-Vinuela, Alicia
    Mory-Rubinos, Nataly
    Gomez-Polo, Cristina
    Ortega, Rocio
    Agustin-Panadero, Ruben
    Gomez-Polo, Miguel
    MATERIALS, 2023, 16 (19)
  • [5] Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck
    Liu, Yang
    Wang, Jiawei
    ARCHIVES OF ORAL BIOLOGY, 2017, 83 : 153 - 160
  • [6] Examination of the implant-abutment interface after fatigue testing
    Cibirka, RM
    Nelson, SK
    Lang, BR
    Rueggeberg, FA
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (03): : 268 - 275
  • [7] Sealing Capability and SEM Observation of the Implant-Abutment Interface
    Lorenzoni, Fabio C.
    Coelho, Paulo G.
    Bonfante, Gerson
    Carvalho, Ricardo M.
    Silva, Nelson R. F. A.
    Suzuki, Marcelo
    Silva, Thelma Lopes
    Bonfante, Estevam A.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2011, 2011
  • [8] The survival of dental implants with different implant-abutment connection systems
    Szpak, Piotr
    Szymanska, Jolanta
    CURRENT ISSUES IN PHARMACY AND MEDICAL SCIENCES, 2016, 29 (01) : 11 - 13
  • [9] Longitudinal Observation of Micromotion upon Loading of Implant-Abutment Connection
    Yamashita, Kohei
    Kataoka, Yu
    Munakata, Motohiro
    Yamaguchi, Kikue
    Hayashi, Myu
    Baba, Daisuke
    BIOENGINEERING-BASEL, 2024, 11 (06):
  • [10] Influence of connection geometry on dynamic micromotion at the implant-abutment interface
    Meng, Joe C.
    Everts, Joshua E.
    Qian, Fang
    Gratton, David G.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2007, 20 (06) : 623 - 625