Integrating a high proportion of intermittent renewable energy provides a solution for the higher peak-shaving capacity of coal-fired power plants. Oxy-fuel combustion is one of the most promising carbon reduction technologies for coal-fired power plants. This study has proposed a novel oxy-fuel power plant that is coupled with both liquid O-2 storage and cold energy recovery systems in order to adapt to the peak-shaving requirements. The liquid O-2 storage system uses cheap valley electricity to produce liquid O-2 for a later use in the peak period to enhance the peak-shaving capacity. Meanwhile, the cold energy recovery system has been introduced to recover the physical latent energy during the phase change of liquid O-2 to increase the power generation in the peak period. Technical economies of three power plants, i.e. a 330 MW (e) oxy-fuel power plant as reference (Case 1), the same power plant coupled with only liquid O-2 storage system (Case 2), and the same power plant coupled with both liquid O-2 storage and cold energy recovery systems (Case 3), have been analyzed and compared. Thermodynamic performance analysis indicates that the peaking capacity of Case 3 can reach the range of 106.03 to 294.22 MW (e), and the maximum peak-shaving coefficient can be as high as 2.77. Exergy analysis demonstrates that the gross exergy efficiency of Cases 2 and 3 reaches 32.18% and 33.57%, respectively, in the peak period, which are significantly higher than that of 26.70% in Case 1. Economic analysis shows that through selling the liquid O-2 and liquid CO2, combined with carbon trading, the levelized cost of electricity (LCOE) of the three cases have been greatly reduced, with the lowest one of 30.90 USD/MWh shown in Case 3. For a comprehensive consideration, Case 3 can be considered a future reference of oxy-fuel power plant with the best thermodynamic and economic performance.
引用
收藏
页码:1722 / 1736
页数:15
相关论文
共 50 条
  • [1] Peak-Shaving of the Oxy-Fuel Power Plant Coupled with Liquid O2 Storage
    Xuchen Fu
    Jianwen Wu
    Zhenkun Sun
    Yuanqiang Duan
    Zhengping Gao
    Lunbo Duan
    Journal of Thermal Science, 2023, 32 : 1722 - 1736
  • [2] Peak-Shaving of the Oxy-Fuel Power Plant Coupled with Liquid O2 Storage
    FU Xuchen
    WU Jianwen
    SUN Zhenkun
    DUAN Yuanqiang
    GAO Zhengping
    DUAN Lunbo
    Journal of Thermal Science, 2023, 32 (05) : 1722 - 1736
  • [3] PEAK-SHAVING RATIO ANALYSIS OF THE NATURAL GAS COMBINED HEAT AND POWER PLANT WITH DISTRIBUTED PEAK-SHAVING HEAT PUMPS
    Zhao, Xiling
    Wang, Xiaoyin
    Sun, Tao
    PROCEEDINGS OF THE ASME 11TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2017, 2017,
  • [4] Power systems' optimal peak-shaving applying secondary storage
    Levron, Yoash
    Shmilovitz, Doron
    ELECTRIC POWER SYSTEMS RESEARCH, 2012, 89 : 80 - 84
  • [5] The Characteristics of a Modern Oxy-Fuel Power Plant
    Kotowicz, Janusz
    Michalski, Sebastian
    Brzeczek, Mateusz
    ENERGIES, 2019, 12 (17)
  • [6] Sensitivity analysis of oxy-fuel power plant system
    Yan, Kai
    Wu, Xiaojiang
    Hoadley, Andrew
    Xu, Xueyuan
    Zhang, Jianwen
    Zhang, Lian
    ENERGY CONVERSION AND MANAGEMENT, 2015, 98 : 138 - 150
  • [7] Privacy Preservation Trading Strategy for Power Peak-shaving Market with Participation of Virtual Power Plant
    Zuo, Juan
    Ai, Qian
    Wang, Di
    Wang, Wenbo
    Xu, Chongxin
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2024, 48 (18): : 149 - 157
  • [8] Complex exergy analysis of an integrated oxy-fuel combustion power plant with CO2 transport and storage
    Gladysz, Pawel
    Ziebik, Andrzej
    JOURNAL OF POWER TECHNOLOGIES, 2015, 95 (05): : 23 - 31
  • [9] Transient multi-objective optimization of solar and fuel cell power generation systems with hydrogen storage for peak-shaving applications
    Hai, Tao
    Kumar, Amit
    Aminian, Saman
    Mahariq, Ibrahim
    Sillanpaa, Mika
    Fouad, Hassan
    El-Shafai, Walid
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 64 : 220 - 235
  • [10] Enhancing peak-shaving capacity of coal-fired power plant by coupling molten salt energy storage and steam accumulator
    Xie, Shutao
    Tan, Peng
    Yu, Zetao
    Zhang, Cheng
    Fang, Qingyan
    Chen, Gang
    JOURNAL OF ENERGY STORAGE, 2025, 117