Image-based ring size prediction for mitral valve repair

被引:5
作者
Akansel, Serdar [1 ,2 ,6 ]
Kofler, Markus [1 ,2 ,3 ]
Van Praet, Karel M. [1 ,2 ,3 ]
Sundermann, Simon H. [1 ,2 ,3 ]
Kukucka, Marian [2 ,4 ]
Jacobs, Stephan [1 ,2 ,3 ]
Falk, Volkmar [1 ,2 ,3 ,5 ]
Kempfert, Joerg [1 ,2 ,3 ]
机构
[1] Deutsch Herzzentrum Charite DHZC, Dept Cardiothorac & Vasc Surg, Berlin, Germany
[2] Charite Univ Med Berlin, Dept Cardiovasc Surg, Berlin, Germany
[3] DZHK German Ctr Cardiovasc Res, Partner Site Berlin, Berlin, Germany
[4] Deutsch Herzzentrum Charite DHZC, Dept Anesthesiol, Berlin, Germany
[5] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, Zurich, Switzerland
[6] Deutsch Herzzentrum Charite DHZC, Dept Cardiothorac & Vasc Surg, Augustenburger Pl 1, D-13353 Berlin, Germany
关键词
Mitral valve repair; Ring annuloplasty; Ring sizing; Ring size prediction; Image-based ring sizing; SYSTOLIC ANTERIOR MOTION; ANNULOPLASTY; REGURGITATION; MANAGEMENT;
D O I
10.1093/ejcts/ezad212
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Annuloplasty rings are routinely used in mitral valve repair (MVr). However, accurate annuloplasty ring size selection is essential to obtain a favourable outcome. Moreover, ring sizing can be challenging in some patients and is highly influenced by surgeons' experience. This study investigated the utility of three-dimensional mitral valve (3D-MV) reconstruction models to predict annuloplasty ring size for MVr. METHODS: A total of 150 patients undergoing minimally invasive MVr with annuloplasty ring due to Carpentier type II pathology and who were discharged with none/trace residual mitral regurgitation were included. 3D-MV reconstruction models were created with a semi-automated software package (4D MV Analysis) to quantitate mitral valve geometry. To predict the ring size, univariable and multivariable linear regression analyses were performed. RESULTS: Between 3D-MV reconstruction values and implanted ring sizes, the highest correlation coefficients were provided by commissural width (CW) (0.839; P < 0.001), intertrigonal distance (ITD) (0.796; P < 0.001), annulus area (0.782; P < 0.001), anterior mitral leaflet area (0.767; P < 0.001), anterior-posterior diameter (0.679; P < 0.001) and anterior mitral leaflet length (0.515; P < 0.001). In multivariable regression analysis, only CW and ITD were found to be independent predictors of annuloplasty ring size (R-2 = 0.743; P < 0.001). The highest level of agreement was achieved with CW and ITD, and 76.6% of patients received a ring with no >1 ring size difference from the predicted ring sizes. CONCLUSIONS: 3D-MV reconstruction models can support surgeons in the decision-making process for annuloplasty ring sizing. The present study may be a first step towards accurate annuloplasty ring size prediction using multimodal machine learning decision support.
引用
收藏
页数:8
相关论文
共 24 条
[1]   Large annuloplasty rings facilitate mitral valve repair in Barlow's disease [J].
Adams, David H. ;
Anyanwu, Ani C. ;
Rahmanian, Parwis B. ;
Abascal, Vivian ;
Salzberg, Sacha P. ;
Filsoufi, Farzan .
ANNALS OF THORACIC SURGERY, 2006, 82 (06) :2096-2101
[2]   Minimally invasive mitral valve surgery after failed transcatheter mitral valve repair in an intermediate-risk cohort [J].
Akansel, Serdar ;
Kofler, Markus ;
Van Praet, Karel M. ;
Unbehaun, Axel ;
Suendermann, Simon H. ;
Jacobs, Stephan ;
Falk, Volkmar ;
Kempfert, Joerg .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2022, 35 (02)
[3]   Sizing for Mitral Annuloplasty: Where Does Science Stop and Voodoo Begin? [J].
Bothe, Wolfgang ;
Miller, D. Craig ;
Doenst, Torsten .
ANNALS OF THORACIC SURGERY, 2013, 95 (04) :1475-1483
[4]   Restrictive mitral annuloplasty cures ischemic mitral regurgitation and heart failur [J].
Braun, Jerry ;
van de Veire, Nico R. ;
Klautz, Robert J. M. ;
Versteegh, Michel I. M. ;
Holman, Eduard R. ;
Westenberg, Jos J. M. ;
Boersma, Eric ;
van der Wall, Ernst E. ;
Bax, Jeroen J. ;
Dion, Robert A. E. .
ANNALS OF THORACIC SURGERY, 2008, 85 (02) :430-437
[5]  
CARPENTIER A, 1983, J THORAC CARDIOV SUR, V86, P323
[6]   THE PHYSIO-RING - AN ADVANCED CONCEPT IN MITRAL-VALVE ANNULOPLASTY [J].
CARPENTIER, AF ;
LESSANA, A ;
RELLAND, JYM ;
BELLI, E ;
MIHAILEANU, S ;
BERREBI, AJ ;
PALSKY, E ;
LOULMET, DF .
ANNALS OF THORACIC SURGERY, 1995, 60 (05) :1177-1186
[7]   Can three-dimensional echocardiography accurately predict complexity of mitral valve repair? [J].
Chikwe, Joanna ;
Adams, David H. ;
Su, Kevin N. ;
Anyanwu, Anelechi C. ;
Lin, Hung-Mo ;
Goldstone, Andrew B. ;
Lang, Roberto M. ;
Fischer, Gregory W. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (03) :518-524
[8]  
Cook RC, 2006, J HEART VALVE DIS, V15, P524
[9]   Late Outcomes of Mitral Valve Repair for Mitral Regurgitation Due to Degenerative Disease [J].
David, Tirone E. ;
Armstrong, Susan ;
McCrindle, Brian W. ;
Manlhiot, Cedric .
CIRCULATION, 2013, 127 (14) :1485-1492
[10]   Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography [J].
Ender, J. ;
Eibel, S. ;
Mukherjee, C. ;
Mathioudakis, D. ;
Borger, M. A. ;
Jacobs, S. ;
Mohr, F. W. ;
Falk, V. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2011, 12 (06) :445-453