Performance analysis of a 50 kW grid-tied PV system on energy productivity in a technical institution building and mitigation method to improve the low power factor problem

被引:4
作者
Afsher, P. A. [1 ,2 ]
Kumar, M. V. Manoj [2 ]
机构
[1] APJ Abdul Kalam Technol Univ, Thiruvananthapuram 695016, Kerala, India
[2] Govt Coll Engn, Dept Elect & Elect Engn, Kannur 670563, Kerala, India
关键词
Grid; Grid-tied system; PV plant; Power factor; Solar photovoltaic; INVERTER;
D O I
10.1016/j.ref.2023.05.009
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A 50-kW grid-interactive solar photovoltaic (SPV) power plant was installed on the rooftop of the Government College of Engineering Kannur (GCEK) in Kerala, India (11 degrees 590900N, 75 degrees 2205500E) on 28th May 2018. The plant was funded by an initial capital investment of (sic)36 Lakh, including a subsidy of (sic)16 Lakh from the Ministry of New and Renewable Energy (MNRE) of the Government of India. The plant has been operating smoothly, with an average energy production of 150 kWh per day. However, a review of the monthly electricity bills of the institution showed that the interconnection of the PV plant has resulted in a power factor penalty of approximately (sic)3.5 Lakh for a period of 3 years. This prompted fur-ther analysis to identify the cause of the low power factor. The goal of this work is to study and analyze the 50-kW solar plant, focusing on the reasons for the low power factor and suggesting methods to improve the power factor of the GCEK power system. This type of analysis will be useful while designing a SPV power plant for a technical institution in a country like India with similar load profile.& COPY; 2023 Elsevier Ltd. All rights reserved.
引用
收藏
页码:126 / 135
页数:10
相关论文
共 23 条
[1]   A PV-DSTATCOM With Adaptive DC-Link Voltage for Grid Integration and PQ Enhancement [J].
Afsher, P. A. ;
Kumar, M. V. Manoj ;
Mukundan, C. M. Ninnal ;
Shyju, K. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (05) :6471-6484
[2]  
Afsher P.A., 2020, 2020 INT C POWER ELE, P1, DOI [10.1109/PEREA51218.2020.9339768, DOI 10.1109/PEREA51218.2020.9339768]
[3]  
[Anonymous], STAT STAT SHEET OFF
[4]   Overcoming the power factor apparent degradation of loads fed by photovoltaic distributed generators [J].
Benedito, Ricardo da Silva ;
Zilles, Roberto ;
Pinho, Joao Tavares .
RENEWABLE ENERGY, 2021, 164 (164) :1364-1375
[5]   A Hysteresis Current Controller PWM Scheme Applied to Three-Level NPC Inverter for Distributed Generation Interface [J].
Chavali, Ravi Varma ;
Dey, Anubrata ;
Das, Biswarup .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (02) :1486-1495
[6]  
Choi J., 2022, Probabilistic Power Syst. Expansion PlanningRenew. Energy Resour. Energy Storage Syst., P127, DOI [10.1002/9781119819042.ch8, DOI 10.1002/9781119819042.CH8]
[7]   Robust maximum power point tracking scheme for PV systems based on attractive ellipsoid method [J].
Cortes-Vega, David ;
Alazki, Hussain .
SUSTAINABLE ENERGY GRIDS & NETWORKS, 2021, 25
[8]   Design for reliability of multifunctional PV inverters used in industrial power factor regulation [J].
Gusman, L. S. ;
Pereira, H. A. ;
Callegari, J. M. S. ;
Cupertino, A. F. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 119
[9]  
Hordeski M.F., 2005, EMERGENCY BACKUP POW, P171
[10]  
Hordeski M.F., 2011, MEGATRENDS ENERGY EF, P267