Thermal and draught perception in fluctuating stratified thermal environments with intermittent impinging jet ventilation

被引:5
|
作者
Zhou, Bin [1 ]
Li, Zhe [1 ]
Yang, Bin [2 ]
Li, Xiaojing [1 ]
Wang, Faming [3 ]
Wei, Shen [4 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[3] Katholieke Univ Leuven, Dept Biosyst, B-3001 Leuven, Belgium
[4] Univ Coll London UCL, Bartlett Sch Sustainable Construct, London WC1E 7HB, England
基金
中国国家自然科学基金;
关键词
Thermal comfort; Impinging jet ventilation; Intermittent air supply; Fluctuated thermal environment; Draught sensation; AIR SUPPLY-SYSTEM; DISPLACEMENT VENTILATION; COMFORT; FLOW; QUALITY; ROOMS;
D O I
10.1016/j.buildenv.2022.109934
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposes a new integrated air supply strategy of impinging jet ventilation (IJV) and intermittent airflow to improve indoor thermal comfort. Vertical thermal stratification is created by the IJV, and a fluctuating thermal environment is created by the intermittent airflow. Three pulsating periods (3 min, 5 min, and 7 min), two supply air temperatures (18 degrees C and 16 degrees C), and four air supply velocities (1.8 m/s steady, 1.5/2.1 m/s, 0.9/ 2.7 m/s, and 0/3.6 m/s) were designed. In both steady and fluctuating indoor environments, fifteen college students were asked to report their perceptions of thermal sensation, thermal comfort, thermal preference, ankle air movement acceptability and preference, and perceived air quality. The results showed that pulsating airflow could lower the mean air temperature above 0.6 m and raise it below 0.6 m. Furthermore, pulsating airflow could reduce overall and local thermal sensation by up to 0.21 and 0.28 scale unit, respectively, and the thermal sensation difference between the head and the foot by up to 0.23 scale unit. While in neutral thermal conditions, the pulsating period of 3 min had the best cooling effect of the 10 cases, but the corresponding percentage of mean dissatisfied ankle draught was 4.3% higher than in the steady operation case. Draught sensation is so closely related to ankle thermal sensation that extending the pulsating periods to 5 or 7 min could reduce ankle draught risk by up to 12.3%. The perceived air quality did not differ significantly between the steady and intermittent cases. The intermittent operation of IJV was shown to have superior cooling performance in order to improve indoor thermal comfort.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Study of thermal and humidity environment and prediction model in impinging jet ventilation rooms based on thermal and moisture coupling
    Xi, Wentao
    Ye, Xiao
    Du, Peng
    Kang, Yanming
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2025, 267
  • [12] Numerical investigation of the thermal and ventilation performance of a combined impinging jet ventilation and passive chilled beam system
    Hu, Jun
    Kang, Yanming
    Lu, Yihang
    Yu, Jia
    Li, He
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2022, 226
  • [13] Numerical investigation of the thermal and ventilation performance of a combined impinging jet ventilation and passive chilled beam system
    Hu, Jun
    Kang, Yanming
    Lu, Yihang
    Yu, Jia
    Li, He
    Zhong, Ke
    Building and Environment, 2022, 226
  • [14] Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings
    Staveckis, Arturs
    Borodinecs, Anatolijs
    ENERGY AND BUILDINGS, 2021, 235
  • [15] Prediction of thermal and contaminant environment in a room with impinging jet ventilation system by zonal model
    Yamasawa, Haruna
    Kobayashi, Tomohiro
    Yamanaka, Toshio
    Choi, Narae
    Cehlin, Mathias
    Ameen, Arman
    BUILDING AND ENVIRONMENT, 2022, 221
  • [16] Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings
    Staveckis, Arturs
    Borodinecs, Anatolijs
    Energy and Buildings, 2021, 235
  • [17] Assessment of Thermal Comfort and Air Quality of Room Conditions by Impinging Jet Ventilation Integrated with Ductless Personalized Ventilation
    Yang, Bin
    Liu, Pengju
    Liu, Yihang
    Jin, Dacheng
    Wang, Faming
    SUSTAINABILITY, 2022, 14 (19)
  • [18] Airflow Perception and Draught Rating for Varying Thermal Conditions
    Ugursal, Ahmet
    Tassinary, Louis G.
    Culp, Charles H.
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 2, 2014, 120
  • [19] Nonequilibrium Thermal Plasma Jet Impinging on a Substrate
    Trelles, Juan Pablo
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2011, 39 (11) : 2870 - 2871
  • [20] Investigation on the flow and thermal behavior of impinging jet ventilation systems in an office with different heat loads
    Chen, H. J.
    Moshfegh, B.
    Cehlin, M.
    BUILDING AND ENVIRONMENT, 2013, 59 : 127 - 144