Thermal and draught perception in fluctuating stratified thermal environments with intermittent impinging jet ventilation

被引:5
|
作者
Zhou, Bin [1 ]
Li, Zhe [1 ]
Yang, Bin [2 ]
Li, Xiaojing [1 ]
Wang, Faming [3 ]
Wei, Shen [4 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[3] Katholieke Univ Leuven, Dept Biosyst, B-3001 Leuven, Belgium
[4] Univ Coll London UCL, Bartlett Sch Sustainable Construct, London WC1E 7HB, England
基金
中国国家自然科学基金;
关键词
Thermal comfort; Impinging jet ventilation; Intermittent air supply; Fluctuated thermal environment; Draught sensation; AIR SUPPLY-SYSTEM; DISPLACEMENT VENTILATION; COMFORT; FLOW; QUALITY; ROOMS;
D O I
10.1016/j.buildenv.2022.109934
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposes a new integrated air supply strategy of impinging jet ventilation (IJV) and intermittent airflow to improve indoor thermal comfort. Vertical thermal stratification is created by the IJV, and a fluctuating thermal environment is created by the intermittent airflow. Three pulsating periods (3 min, 5 min, and 7 min), two supply air temperatures (18 degrees C and 16 degrees C), and four air supply velocities (1.8 m/s steady, 1.5/2.1 m/s, 0.9/ 2.7 m/s, and 0/3.6 m/s) were designed. In both steady and fluctuating indoor environments, fifteen college students were asked to report their perceptions of thermal sensation, thermal comfort, thermal preference, ankle air movement acceptability and preference, and perceived air quality. The results showed that pulsating airflow could lower the mean air temperature above 0.6 m and raise it below 0.6 m. Furthermore, pulsating airflow could reduce overall and local thermal sensation by up to 0.21 and 0.28 scale unit, respectively, and the thermal sensation difference between the head and the foot by up to 0.23 scale unit. While in neutral thermal conditions, the pulsating period of 3 min had the best cooling effect of the 10 cases, but the corresponding percentage of mean dissatisfied ankle draught was 4.3% higher than in the steady operation case. Draught sensation is so closely related to ankle thermal sensation that extending the pulsating periods to 5 or 7 min could reduce ankle draught risk by up to 12.3%. The perceived air quality did not differ significantly between the steady and intermittent cases. The intermittent operation of IJV was shown to have superior cooling performance in order to improve indoor thermal comfort.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Draught perception in intermittent ventilation at neutral room temperature
    Tawackolian, K.
    Lichtner, E.
    Kriegel, M.
    ENERGY AND BUILDINGS, 2020, 224 (224)
  • [2] Performance and potential energy saving of thermal dryer with intermittent impinging jet
    Kurnia, Jundika C.
    Sasmito, Agus P.
    Xu, Peng
    Mujumdar, Arun S.
    APPLIED THERMAL ENGINEERING, 2017, 113 : 246 - 258
  • [3] Numerical investigation of impinging jet ventilation in ICUs: Is thermal stratification a problem?
    Wang, Lei
    Wang, Zhiqiang
    Zhu, Sirui
    Zhu, Zhe
    Jin, Tao
    Wei, Jianjian
    BUILDING SIMULATION, 2023, 16 (07) : 1173 - 1185
  • [4] Computational investigation on the factors influencing thermal comfort for impinging jet ventilation
    Chen, Huijuan
    Moshfegh, Bahram
    Cehlin, Mathias
    BUILDING AND ENVIRONMENT, 2013, 66 : 29 - 41
  • [5] Numerical investigation of impinging jet ventilation in ICUs: Is thermal stratification a problem?
    Lei Wang
    Zhiqiang Wang
    Sirui Zhu
    Zhe Zhu
    Tao Jin
    Jianjian Wei
    Building Simulation, 2023, 16 : 1173 - 1185
  • [6] Effects of Intermittent Air Velocity on Thermal and Draught Perception - A Field Study in a School Environment
    Wigoe, Hans
    INTERNATIONAL JOURNAL OF VENTILATION, 2013, 12 (03) : 249 - 255
  • [7] Effects of Intermittent Air Velocity on Thermal and Draught Perception During Transient Temperature Conditions
    Wigo, Hans
    INTERNATIONAL JOURNAL OF VENTILATION, 2008, 7 (01) : 59 - 66
  • [8] Numerical study on thermal stratification for impinging jet ventilation system in office buildings
    Hu, Jun
    Kang, Yanming
    Yu, Jia
    Zhong, Ke
    Building and Environment, 2021, 196
  • [9] Numerical study on thermal stratification for impinging jet ventilation system in office buildings
    Hu, Jun
    Kang, Yanming
    Yu, Jia
    Zhong, Ke
    BUILDING AND ENVIRONMENT, 2021, 196
  • [10] Insects in Fluctuating Thermal Environments
    Colinet, Herve
    Sinclair, Brent J.
    Vernon, Philippe
    Renault, David
    ANNUAL REVIEW OF ENTOMOLOGY, VOL 60, 2015, 60 : 123 - 140