Safety and function of programmable ventriculo-peritoneal shunt valves: An in vitro 7 Tesla magnetic resonance imaging study

被引:2
|
作者
Chen, Bixia [1 ,2 ]
Dammann, Philipp [1 ,2 ]
Jabbarli, Ramazan [2 ]
Sure, Ulrich [2 ]
Quick, Harald H. [1 ,3 ]
Kraff, Oliver [1 ]
Wrede, Karsten H. [1 ,2 ]
机构
[1] Univ Duisburg Essen, Erwin L Hahn Inst Magnet Resonance Imaging, Essen, North Rhine Wes, Germany
[2] Univ Duisburg Essen, Univ Hosp Essen, Dept Neurosurg, Essen, Germany
[3] Univ Duisburg Essen, Univ Hosp Essen, High Field & Hybrid MR Imaging, Essen, Germany
来源
PLOS ONE | 2023年 / 18卷 / 10期
关键词
MRI ISSUES; HYDROCEPHALUS;
D O I
10.1371/journal.pone.0292666
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective The quantity of ultra-high field MRI neuroimaging studies has rapidly increased. This study tests function, safety, and image artifacts of two frequently implanted programmable ventriculo-peritoneal (VP) shunt valves in a 7T MRI system. Methods All tests were performed using a whole-body 7T MRI system. Three proGAV 2.0 and 3 CODMAN CERTAS (R) Plus programmable VP-shunt valves were tested in three steps. 1) Deflection angle tests close to the bore opening at the location of a static magnetic field gradient of 3-5 T/m. 2) Valves were fixed on a spherical phantom in 3 positions (a. lateral, b. cranial, c. cranial with 22.5 degrees tilt anteriorly) and assessed for keeping the programmed pressure setting and reprogrammability. 3) Valves were fixed on the phantom and positioned lateral in a radiofrequency head coil. MRI scans were performed for both models, including MPRAGE, GRE and SE sequences. Results Deflection angles were moderate (13 degrees, 14 degrees, 13 degrees) for the proGAV valves and close to critical (43 degrees, 43 degrees, 41 degrees) for the CODMAN valves at the test location. Taking a scaling factor of 2-3 for the maximum spatial magnetic field gradient accessible to a patient within the magnet bore into account renders both valves MR unsafe regarding ferromagnetic attraction. The proGAV valves kept the pressure settings in all positions and were reprogrammable in positions a. and b. In position c., reprogrammability was lost. The CODMAN valves changed their pressure setting and reprogrammability was lost in all positions. MR image signal homogeneity was unaltered in the phantom center, artifacts limit the assessability of structures in close vicinity to the valves. Conclusion Both tested programmable VP-shunt valves are MR unsafe for 7T systems. Novel programming mechanisms using permanent magnets with sufficient magnetic coercivity or magnet-free mechanisms may allow the development of programmable VP-shunt valves that are conditional for 7T MR systems.
引用
收藏
页数:10
相关论文
共 3 条
  • [1] Effect of 3-tesla magnetic resonance imaging on various pressure programmable shunt valves
    Inoue, T
    Kuzu, Y
    Ogasawara, K
    Ogawa, A
    JOURNAL OF NEUROSURGERY, 2005, 103 (02) : 163 - 165
  • [2] Programmable Shunt Valves: In Vitro Assessment of Safety of the Magnetic Field Generated by a Portable Game Machine
    Nakashima, Koji
    Nakajo, Takato
    Kawamo, Michiari
    Kato, Akihito
    Ishigaki, Seiichiro
    Murakami, Hidetomo
    Imaizumi, Yohichi
    Izumiyama, Hitoshi
    NEUROLOGIA MEDICO-CHIRURGICA, 2011, 51 (09) : 635 - 638
  • [3] Prosepective Study to Evaluate Rate and Frequency of Perturbations of Implanted Programmable Hakim Codman Valve After 1.5-Tesla Magnetic Resonance Imaging
    Capitanio, Jody Filippo
    Venier, Alice
    Mazzeo, Lucio Aniello
    Barzaghi, Lina Raffaella
    Acerno, Stefania
    Mortini, Pietro
    WORLD NEUROSURGERY, 2016, 88 : 297 - 299