Dosimetric parameters calculation for 18 MV photon beam in flattening filter (FF) and flattening filter free (FFF) linear accelerators with and without magnetic deflector and lead filter

被引:0
|
作者
Hashemizadeh, Morteza [1 ]
Zabihzadeh, Mansour [1 ,2 ,3 ]
Shahbazian, Hojatollah [3 ]
Fatahi-Asl, Jafar [4 ]
Reshadatian, Marziyeh [1 ]
机构
[1] Ahvaz Jundishapur Univ Med Sci, Sch Med, Dept Med Phys, Ahvaz, Iran
[2] Ahvaz Jundishapur Univ Med Sci, Canc Res Ctr, Ahvaz, Iran
[3] Ahvaz Jundishapur Univ Med Sci, Golestan Hosp, Sch Med, Dept Clin Oncol, Ahvaz, Iran
[4] Ahvaz Jundishapur Univ Med Sci, Fac Paramed, Dept Radiol Technol, Ahvaz, Iran
关键词
dose distribution; electron contamination; flattening filter; lead filter; magnetic deflector (MD); radiotherapy; Monte Carlo (MC) calculation; MONTE-CARLO-SIMULATION; ELECTRON CONTAMINATION; STEREOTACTIC RADIOTHERAPY; MICROBEAM; QUALITY; SOFTWARE; NEUTRON; TRS-398; SURFACE; MOTION;
D O I
10.1088/2057-1976/ad2630
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dosimetric characteristics of the flattening filter (FF) and flattening filter free (FFF) modes of 18 MV therapeutic photon beam were investigated with and without the magnetic deflector (MD) and lead filter. MCNP version 6.1.0 Monte Carlo (MC) code was used to simulate the 18 MV photon beam of 2100 C/D-Varian linear accelerator (LINAC) for the FF and FFF modes. The MD (uniform magnetic flux density of 1 Tesla) and lead filter (thickness of 1 mm) were modeled to remove contaminant electrons. The dosimetric parameters for different scenarios of LINAC's head were calculated. Removing the flattening filter in the FFF mode increased the dose rate, electron contamination, skin dose, out-of-field dose, and un-flatness compared to the FF mode. While the lead filter decreased the contaminant electrons significantly, using the MD removed all secondary electrons from the beam line. The surface dose was decreased by 8.3% and 11.2% for the magnetic deflector (MD) and lead filter in the FF mode, respectively. The surface dose was decreased by 16.8% and 20.3% for the MD and lead filter scenarios in the FFF mode, respectively. The MD and lead filter decreased surface penumbra by 15.5% and 11.5% compared to the FFF mode. Removing the flattening filter from the LINAC's head improves most of the dosimetric characteristics of the 18MV therapeutic beam. The use of a lead filter and magnetic deflector preserves the skin-sparing property of megavoltage beams that deteriorate in FFF mode. However, using a magnetic deflector does not reduce photon fluence and dose rate.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Monte-Carlo simulation of the Siemens Artiste linear accelerator flat 6 MV and flattening filter-free 7 MV beam line
    Sadrollahi, Alemeh
    Nuesken, Frank
    Licht, Norbert
    Ruebe, Christian
    Dzierma, Yvonne
    PLOS ONE, 2019, 14 (01):
  • [32] COMMISSIONING OF PHOTON BEAMS OF A FLATTENING FILTER-FREE LINEAR ACCELERATOR AND THE ACCURACY OF BEAM MODELING USING AN ANISOTROPIC ANALYTICAL ALGORITHM
    Hrbacek, Jan
    Lang, Stephanie
    Kloeck, Stephan
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (04): : 1228 - 1237
  • [33] Elaboration and experimental validation of a Monte Carlo source model for linac 6 MV photon beams with and without Flattening Filter
    Aboulbanine, Zakaria
    Bahhous, Karim
    RADIATION PHYSICS AND CHEMISTRY, 2022, 201
  • [34] Dosimetric comparison of 6 MV and 10 MV flattening filter-free beams using small diameter cone for trigeminal neuralgia radiosurgery
    Blanco, Oscar Abel Apaza
    Venencia, Carlos Daniel
    Moreno, Rogelio Manuel Diaz
    Munoz, Fabian
    Barolo, Franco
    Muriano, Oscar
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2024, 23
  • [35] Characterisation of flattening filter free (FFF) beam properties for initial beam set-up and routine QA, independent of flattened beams
    Paynter, D.
    Weston, S. J.
    Cosgrove, V. P.
    Thwaites, D. I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (01):
  • [36] A 4 MV flattening filter-free beam: commissioning and application to conformal therapy and volumetric modulated arc therapy
    Stevens, S. W.
    Rosser, K. E.
    Bedford, J. L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (13): : 3809 - 3824
  • [37] Effect of an integral quality monitor on 4-, 6-, 10-MV, and 6-MV flattening filter-free photon beams
    Nguyen, Trang Hong Thi
    Yokoyama, Haruna
    Kojima, Hironori
    Isomura, Naoki
    Takemura, Akihiro
    Ueda, Shinichi
    Noto, Kimiya
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (01): : 76 - 91
  • [38] A relative comparison of neutron production between conventional and energy-matched flattening-filter-free (FFF) 10MV modes for an elekta linear accelerator
    Delany, Richard
    Tudor, G. Samuel J.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (04):
  • [39] Dosimetric accuracy of AAA and acuros XB dose calculations within an air cavity for small fields of a 6-MV flattening filter-free beam
    Kang, Sang-Won
    Suh, Tae-Suk
    Chung, Jin-Beom
    Eom, Kuen-Yong
    Kim, In-Ah
    Kim, Jae-Sung
    Lee, Jeong-Woo
    Park, Ji-Yeon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (12) : 2138 - 2145
  • [40] Technical Note: Induced radioactivity in stereotactic body radiation therapy with a flattening-filter-free 10 MV beam model
    Wang, Huidong
    Chen, Kunzhi
    Shi, Yinghua
    Huang, Xiaolong
    Sun, Wuji
    Hou, Kairan
    Jin, Yongli
    Jiang, Xin
    Yang, Dong
    Dong, Lihua
    MEDICAL PHYSICS, 2021, 48 (04) : 2010 - 2017