A Laminated Continuum Robot With Gripping Force-Sensing Forceps for Robot-Assisted Minimally Invasive Surgeries

被引:2
作者
Ju, Feng [1 ]
Hong, Yan [1 ]
Bai, Dongming [2 ,3 ]
Yin, Zhanpeng [1 ]
Zhu, Chengjun [4 ]
Yue, Wenchao [5 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Mech & Elect Engn, Nanjing 210016, Peoples R China
[2] Coll Mech & Elect, Jinhua Polytech, Jinhua 321017, Zhejiang, Peoples R China
[3] Key Lab Crop Harvesting Equipment Technol Zhejiang, Jinhua 321000, Peoples R China
[4] Jiangsu Prov Hosp, Dept Oncol, Nanjing 210029, Peoples R China
[5] Chinese Univ Hong Kong, Dept Elect Engn, Hong Kong 999077, Peoples R China
基金
中国国家自然科学基金;
关键词
Sensors; Robot sensing systems; Robots; Force; Fabrication; Three-dimensional displays; Medical robotics; Continuum robot; gripping force sensor; laminated fabrication; photoelectric sensor; surgical robot; PLATFORM;
D O I
10.1109/JSEN.2022.3223044
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Minimally invasive surgeries (MISs) or natural orifice transluminal endoscopic surgeries (NOTESs), such as the transurethral resection of bladder tumor (TURBT), require the surgical robot to be miniaturized to perform surgical procedures in narrow spaces. However, miniaturization of surgical robots poses problems in its fabrication and sensor integration. In this article, a miniature continuum surgical robot is proposed with force-sensing surgical forceps, which can be fabricated through a 2-D lamination process and converted into 3-D through folding. This multimaterial laminated structure facilitates the integration of photoelectric sensors into the surgical forceps. Then, the gripping force of the surgical forceps is sensed from the change of the output voltage of the integrated photoelectric sensor. The sensitivity of gripping force to the change of output voltage is 3.6 N/V, and the maximum error during calibration is 0.03 N. The proposed robot and the gripping force sensing method are validated through simulations and experiments, such as gripping and releasing objects of various hardness and heights. It is also validated that the gripping force information could also improve the gripping performance in the object handling experiment and ex vivo porcine intestine gripping experiment.
引用
收藏
页码:766 / 774
页数:9
相关论文
共 18 条
[1]  
Back J, 2015, IEEE INT C INT ROBOT, P1528, DOI 10.1109/IROS.2015.7353570
[2]   Miniaturized Optical Force Sensor for Minimally Invasive Surgery With Learning-Based Nonlinear Calibration [J].
Bandari, Naghmeh ;
Dargahi, Javad ;
Packirisamy, Muthukumaran .
IEEE SENSORS JOURNAL, 2020, 20 (07) :3579-3592
[3]   Continuum Robots for Medical Applications: A Survey [J].
Burgner-Kahrs, Jessica ;
Rucker, D. Caleb ;
Choset, Howie .
IEEE TRANSACTIONS ON ROBOTICS, 2015, 31 (06) :1261-1280
[4]   Cable-Less, Magnetically Driven Forceps for Minimally Invasive Surgery [J].
Forbrigger, Cameron ;
Lim, Andrew ;
Onaizah, Onaizah ;
Salmanipour, Sajad ;
Looi, Thomas ;
Drake, James ;
Diller, Eric D. .
IEEE ROBOTICS AND AUTOMATION LETTERS, 2019, 4 (02) :1202-1207
[5]  
GAFFORD JB, 2013, P INT DES ENG TECH C, P1
[6]   Design and Performance Evaluation of a Minimally Invasive Telerobotic Platform for Transurethral Surveillance and Intervention [J].
Goldman, Roger E. ;
Bajo, Andrea ;
MacLachlan, Lara S. ;
Pickens, Ryan ;
Herrell, S. Duke ;
Simaan, Nabil .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (04) :918-925
[7]   Optoelectronic-Based Pose Sensing for a Hand Rehabilitation Exoskeleton Continuous Structure [J].
He, Bo ;
Li, Min ;
Liang, Renghao ;
Liang, Ziting ;
Yao, Wei ;
Sareh, Sina ;
Xie, Jun ;
Xu, Guanghua ;
Noh, Yohan .
IEEE SENSORS JOURNAL, 2022, 22 (06) :5606-5615
[8]   En bloc resection of urothelial cancer within the urinary bladder: the upcoming gold standard? Re: Kramer MW, Wolters M, Cash H, Jutzi S, Imkamp F, Kuczyk MA, Merseburger AS, Herrmann TR. Current evidence of transurethral Ho:YAG and Tm:YAG treatment of bladder cancer: update 2014. World J Urol. 2014 Jun 10. [Epub ahead of print]. doi: 10.1007/s00345-014-1337-y [J].
Karl, Alexander ;
Herrmann, Thomas R. W. .
WORLD JOURNAL OF UROLOGY, 2015, 33 (04) :581-582
[9]   Sensorized Surgical Forceps for Robotic-Assisted Minimally Invasive Surgery [J].
Kim, Uikyum ;
Kim, Yong Bum ;
So, Jinho ;
Seok, Dong-Yeop ;
Choi, Hyouk Ryeol .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (12) :9604-9613
[10]  
Menghao Tian, 2021, 2021 IEEE 7th International Conference on Control Science and Systems Engineering (ICCSSE), P47, DOI 10.1109/ICCSSE52761.2021.9545202