Fire spread in a large compartment with exposed cross-laminated timber and open ventilation conditions: #FRIC-02-Exposed wall and ceiling

被引:5
|
作者
Boe, Andreas Saeter [1 ,4 ]
Friquin, Kathinka Leikanger [2 ]
Brandon, Daniel [3 ]
-Hansen, Anne Steen [1 ,4 ]
Ertesvag, Ivar S. [5 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Fac Engn, Dept Civil & Environm Engn, Trondheim, Norway
[2] SINTEF Community, Dept Architecture Mat & Struct, Trondheim, Norway
[3] RISE Fire Res, Lund, Sweden
[4] RISE Fire Res AS, Trondheim, Norway
[5] NTNU Norwegian Univ Sci & Technol, Fac Engn, Dept Energy & Proc Engn, Trondheim, Norway
关键词
CLT; Fire spread; Large-scale; Compartment fire; Second flashover; Delamination; Facade fire; External flame; FLAME;
D O I
10.1016/j.firesaf.2023.103986
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) is becoming increasingly popular due to its many advantages. However, it has been shown that exposed CLT can have a significant effect on fire dynamics and spread rates. Further studies are therefore needed to better understand the impact of CLT to fire safety. Two large-scale CLT compartment fire experiments (95 m2) representing a modern office building have been performed, #FRIC-01 and #FRIC-02. This paper presents the second experiment, #FRIC-02, with exposed CLT on the back wall and the ceiling. The fire developed fast and spread across the room in less than 3.5 min from ignition of the wood crib on the floor and in 1.5 min after the ignition of the ceiling. Large external flames were observed, despite the compartment being well-ventilated. The 5-layer CLT, which comprised a 40 mm thick exposed outer layer and was face-bonded using a common European polyurethane adhesive, exhibited glue-line integrity failure and led to a second flashover after a significant period of decay. Subsequent layers of 20 mm also delaminated before the fire was manually extinguished after 3 h. Compared to #FRIC-01, the fire spread rate was faster, and temperatures, charring rates, heat release rates and external flames were higher.
引用
收藏
页数:27
相关论文
共 3 条
  • [1] Fire spread in a large compartment with exposed cross-laminated timber and open ventilation conditions: #FRIC-01-Exposed ceiling
    Boe, Andreas Saeter
    Friquin, Kathinka Leikanger
    Brandon, Daniel
    Steen-Hansen, Anne
    Ertesvag, Ivar S.
    FIRE SAFETY JOURNAL, 2023, 140
  • [2] Experimental study on fire performance of cross laminated timber structure exposed to compartment fire
    Zhang J.
    Sun Y.
    Wang Y.
    Lu C.
    Wang W.
    Wu L.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (09): : 115 - 127
  • [3] Large-scale fire experiments in a cross-laminated timber compartment with an adjacent corridor - Partly and fully protected with a water sprinkler system
    Boe, Andreas Saeter
    Hox, Kristian
    Mikalsen, Ragni Fjellgaard
    Friquin, Kathinka L.
    FIRE SAFETY JOURNAL, 2024, 148