Diagnostic accuracy of magnetic resonance imaging in detecting and grading perianal fistulas

被引:0
作者
Minhas, Sidra [1 ]
Raja, Riffat [1 ]
Khaliq, Maria [1 ]
Mahmood, Hassan
Raza, Syed Muhammad [2 ]
Hanif, Hina [1 ]
机构
[1] Holy Family Hosp, Fed Minist Natl Hlth Serv Regulat & Coordinat MNHS, Dept Radiol, Rawalpindi, Pakistan
[2] Cantonment Rawalpindi, Dept Radiol, Rawalpindi, Pakistan
来源
RAWAL MEDICAL JOURNAL | 2023年 / 48卷 / 03期
关键词
Perianal fistula; perianal fistula grading; pelvic MRI; diagnostic accuracy; MRI EVALUATION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To determine the diagnostic accuracy of magnetic resonance imaging (MRI) in detecting and grading perianal fistula, taking operative findings as gold standard. Methodology: This descriptive, cross-sectional study was conducted in department of Radiology & Imaging, Holy Family Hospital, Rawalpindi from 09-06-2019 to 08-12-2019. A total of 100 patients underwent MRI on 1.5 tesla GE machine using a pelvic phased array multicoil. Images were interpreted by experienced radiologist to identify and grade perianal fistula. After surgery, findings were recorded for presence/absence of perianal fistula as well as for anatomical details of fistulous tract. MRI findings were compared with operative findings. Data were analyzed using SPSS version 20.0. Results: MRI showed the presence of perianal fistula in 87 patients. Operative findings confirmed perianal fistula in 89 cases where as 11 patients revealed no perianal fistula. Overall sensitivity (Sn), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy (DA) of MRI in detecting perianal fistula were 95.5%, 81.8%, 97.7%, 69% and 94%, respectively. The most common type of fistula was intersphincteric grade 1 fistula. Abscess formation was more common in grade 3, 4 and 5 fistulas. Internal opening of the fistulous track was most commonly identified posteriorly in midline at 6 O'clock position. Conclusion: MRI is a highly sensitive and accurate imaging modality for pre-operative diagnosis and grading of perianal fistula.
引用
收藏
页码:647 / 650
页数:4
相关论文
共 20 条
  • [1] Abdelnaby M, 2017, J Surg, V5, P22
  • [2] Aggarwal Rohit, 2017, Indian J Radiol Imaging, V27, P161, DOI 10.4103/ijri.IJRI_373_16
  • [3] Akhtar S, 2014, J Postgrad Med Inst, V28, P264
  • [4] Preoperative MRI of perianal fistula evaluation and its impact on surgical outcome
    Algazzar, Hesham Youssef
    Eldib, Diaa Bakry
    Bahram, Mahmoud A.
    Zaher, Nasser A.
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2019, 50 (01)
  • [5] Value of three-dimensional endoanal ultrasound scan (3D-EAUS) in preoperative assessment of fistula-in-ano
    Almeida, Isuru Sampath
    Jayarajah, Umesh
    Wickramasinghe, Dakshitha Praneeth
    Samarasekera, Dharmabandhu Nandadeva
    [J]. BMC RESEARCH NOTES, 2019, 12 (1)
  • [6] Factors Increasing the Risk of Recurrence in Fistula-in-ano
    Bakhtawar, Nabiyah
    Usman, Muhammad
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (03)
  • [7] MRI evaluation of anal and perianal diseases
    Balci, Sinan
    Onur, Mehmet Ruhi
    Karaosmanoglu, Ali Devrim
    Karcaaltincaba, Musturay
    Akata, Deniz
    Konan, Ali
    Ozmen, Mustafa Nasuh
    [J]. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2019, 25 (01) : 21 - 27
  • [8] Carvalho Alexandre Lopes de, 2021, J. Coloproctol. (Rio J.), V41, P275, DOI 10.1055/s-0041-1730015
  • [9] Chaudhari NH., 2016, Int J Res Med Sci, V4, P482, DOI [10.18203/2320-6012.ijrms20160300, DOI 10.18203/2320-6012.IJRMS20160300]
  • [10] Magnetic Resonance Imaging (MRI) Characterization of Perianal Fistulous Disease in a Rural Based Tertiary Hospital of North India
    Chauhan, Narvir Singh
    Sood, Dinesh
    Shukla, Anurag
    [J]. POLISH JOURNAL OF RADIOLOGY, 2016, 81 : 611 - 617