Biomechanical analysis for different mandibular total distalization methods with clear aligners: A finite element study

被引:3
作者
Oh, Sewoong [1 ]
Choi, Youn-Kyung [2 ]
Kim, Sung-Hun [1 ]
Ko, Ching-Chang [3 ]
Kim, Ki Beom [4 ]
Kim, Yong-Il [1 ,5 ]
机构
[1] Pusan Natl Univ, Dent Hosp, Dent Res Inst, Dept Orthodont, Yangsan, South Korea
[2] Pusan Natl Univ Hosp, Dept Orthodont, Busan, South Korea
[3] Ohio State Univ, Coll Dent, Div Orthodont, Columbus, OH USA
[4] St Louis Univ, Dept Orthodont, St Louis, MO USA
[5] Pusan Natl Univ, Dent & Life Sci Inst, Sch Dent, 20 Geumo Ro, Yangsan 50612, South Korea
基金
新加坡国家研究基金会;
关键词
Finite element method; Clear aligner; Distalization; DENTITION; SYSTEM;
D O I
10.4041/kjod23.035
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The purpose of this finite element method (FEM) study was to analyze the biomechanical differences and tooth displacement patterns according to the traction direction, methods, and sites for total distalization of the mandibular dentition using clear aligner treatment (CAT). Methods: A finite element analysis was performed on four FEM models using different traction methods (via a precision cut hook or button) and traction sites (mandibular canine or first premolar). A distalization force of 1.5 N was applied to the traction site by changing the direction from -30 to +30 degrees to the occlusal plane. The initial tooth displacement and von Mises stress on the clear aligners were analyzed. Results: All CAT-based total distalization groups showed an overall trend of clockwise or counterclockwise rotation of the occlusal plane as the force direction varied. Mesiodistal tipping of individual teeth was more prominent than that of bodily movements. The initial displacement pattern of the mandibular teeth was more predominant based on the traction site than on the traction method. The elastic deformation of clear aligners is attributed to unintentional lingual tipping or extrusion of the mandibular anterior teeth. Conclusions: The initial tooth displacement can vary according to different distalization strategies for CAT-based total distalization. Discreet application and biomechanical understanding of traction sites and directions are necessary for appropriate mandibular total distalization.
引用
收藏
页码:420 / 430
页数:11
相关论文
共 50 条
  • [1] Effects of different distalization directions and methods on maxillary total distalization with clear aligners: a finite element study
    Kwak, Kyoung-Ho
    Oh, Sewoong
    Choi, Youn-Kyung
    Kim, Sung-Hun
    Kim, Seong-Sik
    Park, Soo-Byung
    Kim, Yong-Il
    ANGLE ORTHODONTIST, 2023, 93 (03) : 348 - 356
  • [2] Biomechanical effects of periodontal status on molar sequential distalization with clear aligners: a finite element study
    Ma, Yanning
    Fan, Xinyue
    Liu, Xulin
    Zhang, Mingxin
    Jin, Zuolin
    Gao, Jie
    PROGRESS IN ORTHODONTICS, 2025, 26 (01):
  • [3] Different biomechanical effects of clear aligners in closing maxillary and mandibular extraction spaces: Finite element analysis
    Liu, Jun-qi
    Zhu, Guan-yin
    Wang, Yi-gan
    Zhang, Bo
    Yao, Ke
    Zhao, Zhi-he
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2023, 163 (06) : 811 - 824.e2
  • [4] Evaluation of biomechanics using different traction devices in distalization of maxillary molar with clear aligners: a finite element study
    Ji, Lili
    Li, Bing
    Wu, Xiuping
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (05) : 559 - 567
  • [5] Biomechanical effects of different mandibular movements and torque compensations during mandibular advancement with clear aligners: a finite element analysis
    Wang, Ya
    Daraqel, Baraa
    Wang, Ying
    Yang, Dan
    Dong, Yihan
    Hu, Yun
    Zheng, Leilei
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [6] Three-dimensional finite element analysis of maxillary molar distalization treated with clear aligners combined with different traction methods
    Gao, Hongyu
    Luo, Liangyu
    Liu, Jun
    PROGRESS IN ORTHODONTICS, 2024, 25 (01):
  • [7] Biomechanical analysis of miniscrew-assisted molar distalization with clear aligners: a three-dimensional finite element study
    Guo, Runzhi
    Lam, Xiang Yao
    Zhang, Liwen
    Li, Weiran
    Lin, Yifan
    EUROPEAN JOURNAL OF ORTHODONTICS, 2024, 46 (01)
  • [8] Biomechanical Characteristics of Maxillary Molar Distalization Using Different Attachments with Clear Aligners: A 3-Dimensional Finite Element Analysis
    Chi, Jingwen
    Yang, Lixia
    Liu, Yicong
    Yang, Jianjun
    Deng, Jing
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2022, 12 (09) : 1738 - 1744
  • [9] Upper Second Molar Distalization with Clear Aligners: A Finite Element Study
    Rossini, Gabriele
    Schiaffino, Matteo
    Parrini, Simone
    Sedran, Ambra
    Deregibus, Andrea
    Castroflorio, Tommaso
    APPLIED SCIENCES-BASEL, 2020, 10 (21): : 1 - 9
  • [10] Effects of Mandibular Extractions with Clear Aligners: A Finite Element Analysis
    Feng Q.
    Chu F.
    Chen R.
    Pan X.
    Journal of Shanghai Jiaotong University (Science), 2021, 26 (3) : 377 - 382