Implant-Supported Fixed Partial Dentures with Posterior Cantilevers: In Vitro Study of Mechanical Behavior

被引:0
|
作者
Bonmati, Fernando Garcia-Sala [1 ]
Bustamante-Hernandez, Naia [2 ]
Alonso Perez-Barquero, Jorge [1 ]
Maneiro-Lojo, Jesus [1 ]
Fons-Badal, Carla [1 ]
Labaig-Caturla, Carla [1 ]
Fernandez-Estevan, Lucia [1 ]
Agustin-Panadero, Ruben [1 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Dent Med, Valencia 46010, Spain
[2] Univ Basque Country, Fac Med & Dent, Dept Stomatol, Leioa 48940, Spain
关键词
mechanical behavior; cyclic loading; compressive loading; implant-supported fixed partial denture; posterior cantilever; DENTAL PROSTHESES; FRACTURE LOAD; ZIRCONIA; ABUTMENTS; STRENGTH; SCREW; THICKNESS;
D O I
10.3390/ma16206805
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Rehabilitation with dental implants is not always possible due to the lack of bone quality or quantity, in many cases due to bone atrophy or the morbidity of regenerative treatments. We find ourselves in situations of performing dental prostheses with cantilevers in order to rehabilitate our patients, thus simplifying the treatment. The aim of this study was to analyze the mechanical behavior of four types of fixed partial dentures with posterior cantilevers on two dental implants (convergent collar and transmucosal internal connection) through an in vitro study (compressive loading and cyclic loading). This study comprised four groups (n = 76): in Group 1, the prosthesis was screwed directly to the implant platform (DS; n = 19); in Group 2, the prosthesis was screwed to the telescopic interface on the implant head (INS; n = 19); in Group 3, the prosthesis was cemented to the telescopic abutment (INC; n = 19); and in Group 4, the prosthesis was cemented to the abutment (DC; n = 19). The sets were subjected to a cyclic loading test (80 N load for 240,000 cycles) and compressive loading test (100 KN load at a displacement rate of 0.5 mm/min), applying the load until failure occurred to any of the components at the abutment-prosthesis-implant interface. Subsequently, an optical microscopy analysis was performed to obtain more data on what had occurred in each group. Results: Group 1 (direct screw-retained prosthesis, DS) obtained the highest mean strength value of 663.5 +/- 196.0 N. The other three groups were very homogeneous: 428.4 +/- 63.1 N for Group 2 (INS), 486.7 +/- 67.8 N for Group 3 (INC), and 458.9 +/- 38.9 N for Group 4 (DC). The mean strength was significantly dependent on the type of connection (p < 0.001), and this difference was similar for all of the test conditions (cyclic and compressive loading) (p = 0.689). Implant-borne prostheses with convergent collars and transmucosal internal connections with posterior cantilevers screwed directly to the implant connection are a good solution in cases where implant placement cannot avoid extensions.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] A Protocol for Screw-Retrievable, Cement-Retained, Implant-Supported Fixed Partial Dentures
    AlHelal, Abdulaziz
    Kattadiyil, Mathew T.
    AlBader, Bader
    Clark, Jefferson L.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (06) : 577 - 580
  • [32] Oral health-related quality of life in patients treated by implant-supported fixed dentures and removable partial dentures
    Furuyama, Chisako
    Takaba, Masayuki
    Inukai, Mika
    Mulligan, Roseann
    Igarashi, Yoshimasa
    Baba, Kazuyoshi
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (08) : 958 - 962
  • [33] Mechanical performance of implant-supported posterior crowns
    de Kok, Paul
    Kleverlaan, Cornelis J.
    de Jager, Niek
    Kuijs, Ruud
    Feilzer, Albert J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (01): : 59 - 66
  • [34] The prognosis of partial implant-supported fixed dental prostheses with cantilevers. A 5-year retrospective cohort study
    Malo, Paulo
    Nobre, Miguel de Araujo
    Lopes, Armando
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2013, 6 (01) : 51 - 59
  • [35] Clinical Evaluation of Mandibular Posterior Three-Unit Combined Tooth-/Implant-Supported Fixed Partial Dentures: Controlled Prospective Clinical Study
    Ekren, Orhun
    Kocak, Elif Figen
    Ucar, Yurdanur
    Benlidayi, Mehmet Emre
    Tukel, Huseyin Can
    Yuksel, Hazal Duyan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (03) : 426 - 434
  • [36] An in vitro investigation comparing methods of minimizing excess luting agent for cement-retained implant-supported fixed partial dentures
    Bukhari, Sarah A.
    AlHelal, Abdulaziz
    Kattadiyil, Mathew T.
    Wadhwani, Chandur P. K.
    Taleb, Abdulrahman
    Dehom, Salem
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 706 - 715
  • [37] Maintenance requirements of implant-supported fixed prostheses opposed by implant-supported fixed prostheses, natural teeth, or complete dentures: A 5-year retrospective study
    Davis, DM
    Packer, ME
    Watson, RM
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (05) : 521 - 523
  • [38] Comparison of Treatment Outcomes in Partially Edentulous Patients with Implant-Supported Fixed Prostheses and Removable Partial Dentures
    Nogawa, Toshifumi
    Takayama, Yoshiyuki
    Ishida, Keita
    Yokoyama, Atsuro
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (06) : 1376 - 1383
  • [39] Impact of tilted implants for implant-supported fixed partial dentures: A systematic review with meta-analysis
    Batista, Rhaslla Gonsalves
    Fae, Daniele Sorgatto
    Bento, Victor Augusto Alves
    Rosa, Cleber Davi Del Rey Daltro
    Batista, Victor Eduardo de Souza
    Pellizzer, Eduardo Piza
    Lemos, Cleidiel Aparecido Araujo
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05): : 890 - 897
  • [40] The Effect of Different Restorative and Abutment Materials on Marginal and Internal Adaptation of Three-Unit Cantilever Implant-Supported Fixed Partial Dentures: An In Vitro Study
    Kahramanoglu, Erkut
    Kulak-Ozkan, Yasemin
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (08): : 608 - 617