Implant-Supported Fixed Partial Dentures with Posterior Cantilevers: In Vitro Study of Mechanical Behavior

被引:0
|
作者
Bonmati, Fernando Garcia-Sala [1 ]
Bustamante-Hernandez, Naia [2 ]
Alonso Perez-Barquero, Jorge [1 ]
Maneiro-Lojo, Jesus [1 ]
Fons-Badal, Carla [1 ]
Labaig-Caturla, Carla [1 ]
Fernandez-Estevan, Lucia [1 ]
Agustin-Panadero, Ruben [1 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Dent Med, Valencia 46010, Spain
[2] Univ Basque Country, Fac Med & Dent, Dept Stomatol, Leioa 48940, Spain
关键词
mechanical behavior; cyclic loading; compressive loading; implant-supported fixed partial denture; posterior cantilever; DENTAL PROSTHESES; FRACTURE LOAD; ZIRCONIA; ABUTMENTS; STRENGTH; SCREW; THICKNESS;
D O I
10.3390/ma16206805
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Rehabilitation with dental implants is not always possible due to the lack of bone quality or quantity, in many cases due to bone atrophy or the morbidity of regenerative treatments. We find ourselves in situations of performing dental prostheses with cantilevers in order to rehabilitate our patients, thus simplifying the treatment. The aim of this study was to analyze the mechanical behavior of four types of fixed partial dentures with posterior cantilevers on two dental implants (convergent collar and transmucosal internal connection) through an in vitro study (compressive loading and cyclic loading). This study comprised four groups (n = 76): in Group 1, the prosthesis was screwed directly to the implant platform (DS; n = 19); in Group 2, the prosthesis was screwed to the telescopic interface on the implant head (INS; n = 19); in Group 3, the prosthesis was cemented to the telescopic abutment (INC; n = 19); and in Group 4, the prosthesis was cemented to the abutment (DC; n = 19). The sets were subjected to a cyclic loading test (80 N load for 240,000 cycles) and compressive loading test (100 KN load at a displacement rate of 0.5 mm/min), applying the load until failure occurred to any of the components at the abutment-prosthesis-implant interface. Subsequently, an optical microscopy analysis was performed to obtain more data on what had occurred in each group. Results: Group 1 (direct screw-retained prosthesis, DS) obtained the highest mean strength value of 663.5 +/- 196.0 N. The other three groups were very homogeneous: 428.4 +/- 63.1 N for Group 2 (INS), 486.7 +/- 67.8 N for Group 3 (INC), and 458.9 +/- 38.9 N for Group 4 (DC). The mean strength was significantly dependent on the type of connection (p < 0.001), and this difference was similar for all of the test conditions (cyclic and compressive loading) (p = 0.689). Implant-borne prostheses with convergent collars and transmucosal internal connections with posterior cantilevers screwed directly to the implant connection are a good solution in cases where implant placement cannot avoid extensions.
引用
收藏
页数:13
相关论文
共 50 条
  • [2] Survival and complication rates of implant-supported fixed partial dentures with cantilevers: a systematic review
    Zurdo, Jose
    Romao, Cristina
    Wennstrom, Jan L.
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 : 59 - 66
  • [3] A Method for Fabrication of Implant-Supported Fixed Partial Dentures
    Zafiropoulos, Gregory-George
    Hoffmann, Oliver
    Deli, Georgio
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (03) : 271 - 279
  • [4] In vitro study on passive fit in implant-supported 5-unit fixed partial dentures
    Karl, M
    Winter, W
    Taylor, TD
    Heckmann, SM
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (01) : 30 - 37
  • [5] Limited evidence that cantilevers are associated with slightly lower survival rates of implant-supported fixed partial dentures
    Lee, Heeje
    Yu, Alika
    Flores-Mir, Carlos
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (11): : 1371 - 1372
  • [6] BIOLOGICAL AND MECHANICAL-TECHNICAL COMPLICATIONS OF POSTERIOR METAL-CERAMIC IMPLANT-SUPPORTED FIXED PARTIAL DENTURES: A RETROSPECTIVE STUDY
    Bardis, Dimitrios
    Agop-Forna, Doriana
    Dascalu, Cristina
    Cristea, Ioana
    Forna, Norina
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2022, 14 (03): : 18 - 26
  • [7] The impact of cantilevers on biological and technical success outcomes of implant-supported fixed partial dentures. A retrospective cohort study
    Kim, Paul
    Ivanovski, Saso
    Latcham, Neil
    Mattheos, Nikos
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : 175 - 184
  • [8] Patient evaluation of treatment with fixed implant-supported partial dentures
    Yi, SW
    Carlsson, GE
    Ericsson, I
    Kim, CK
    JOURNAL OF ORAL REHABILITATION, 2001, 28 (11) : 998 - 1002
  • [9] Modeling and Simulation of Implant-supported Fixed Partial Dentures Prosthodontic
    Liu, Donglei
    Yan, Hua
    Shen, Zongbao
    Song, Xinhua
    Wang, Xiao
    E-ENGINEERING & DIGITAL ENTERPRISE TECHNOLOGY VII, PTS 1 AND 2, 2009, 16-19 : 1112 - 1116
  • [10] The Influence of Interproximal Contact on Implant-Supported Fixed Partial Dentures in the Posterior Jaw A Photoelastic Analysis
    Naves, Marina Melo
    Machado de Menezes, Helder Henrique
    de Magalhaes, Denildo
    de Araujo, Cleudmar Amaral
    Simamoto Junior, Paulo Cezar
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (01) : 3 - 9