Multi-objective optimization of energy-saving measures and operation parameters for a newly retrofitted building in future climate conditions: A case study of an office building in Chengdu

被引:28
作者
Gao, Bo [1 ]
Zhu, Xiaoyue [2 ]
Ren, Jing [3 ]
Ran, Jingyu [3 ]
Kim, Moon Keun [4 ]
Liu, Jiying [3 ,5 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu 610030, Peoples R China
[2] Sichuan Inst Bldg Res, Chengdu 610084, Peoples R China
[3] Shandong Jianzhu Univ, Sch Thermal Engn, Jinan 250101, Peoples R China
[4] Oslo Metropolitan Univ, Dept Built Environm, N-0130 Oslo, Norway
[5] Shandong Jianzhu Univ, Sch Thermal Engn, 1000 Fengming Rd, Jinan 250101, Peoples R China
关键词
Multi -objective optimization; Climate change; Newly retrofitted office building; Energy savings; NSGA-II; RESIDENTIAL BUILDINGS; NIGHT VENTILATION; IMPACT; PERFORMANCE; DESIGN; STABILIZATION; MITIGATION; STRATEGIES; ALGORITHM; PATHWAY;
D O I
10.1016/j.egyr.2023.01.049
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The energy-saving measures and suitable operation parameters will be urgent concerns in future global climate change conditions. However, a critical review revealed that most studies considered upgrading the wall insulation and glazing in the design process or the retrofit stage for existing buildings built before the twenty-first century and neglected improving system energy efficiency and operation of newly retrofitted buildings with higher-performance envelopes in the context of the carbon peak and carbon neutrality. Therefore, a real and newly retrofitted office building in Chengdu was investigated. The effect of indoor cooling and heating temperature setpoints, water supply/return temperature setpoints for the air-conditioning system, night ventilation settings in summer, and renewable energy variables (photovoltaic) are considered in the optimization. The simulation model was validated using the monitored heating and cooling energy consumption. Transient system simulation coupled with jEPlus + an evolutionary algorithm and the non-dominated sorting genetic algorithm were used to explore the optimal solution to reduce carbon emission and energy consumption while ensuring acceptable indoor thermal comfort. The sensitivity analysis showed night ventilation duration and the air change rate had significant effects on carbon emission reduction. The annual carbon emission reduction of the building was 46500-58500 kg from 2030 to 2060 using a photovoltaic panel area of 1000 m2. The indoor temperature setpoint decreased over time due to the increasing outdoor temperature in the future. Moreover, the building energy system showed a better performance when the air source heat pump cooling setpoint was increased from 7 degrees C to 9 degrees C. Decreasing the air source heat pump heating setpoint from 45 degrees C to 42.5 degrees C for 2030 and 2060, and from 45 degrees C to 40 degrees C for 2040 and 2050 were the optimal solutions. The proposed approach provides guidance for operators to optimize energy savings and operation parameters under future climate conditions.(c) 2023 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:2269 / 2285
页数:17
相关论文
共 87 条
  • [31] Multi-Objective Optimization of the Envelope of Building with Natural Ventilation
    Grygierek, Krzysztof
    Ferdyn-Grygierek, Joanna
    [J]. ENERGIES, 2018, 11 (06):
  • [32] Preparation of future weather data to study the impact of climate change on buildings
    Guan, Lisa
    [J]. BUILDING AND ENVIRONMENT, 2009, 44 (04) : 793 - 800
  • [33] Global scenarios of urban density and its impacts on building energy use through 2050
    Guneralp, Burak
    Zhou, Yuyu
    Urge-Vorsatz, Diana
    Gupta, Mukesh
    Yu, Sha
    Patel, Pralit L.
    Fragkias, Michail
    Li, Xiaoma
    Seto, Karen C.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2017, 114 (34) : 8945 - 8950
  • [34] Feasible roadmap for CCS retrofit of coal-based power plants to reduce Chinese carbon emissions by 2050
    Guo, Jian-Xin
    Huang, Chen
    [J]. APPLIED ENERGY, 2020, 259
  • [35] Optimization of night ventilation performance in office buildings in a cold climate
    Guo, Rui
    Heiselberg, Per
    Hu, Yue
    Zhang, Chen
    Vasilevskis, Sandijs
    [J]. ENERGY AND BUILDINGS, 2020, 225
  • [36] Modelling building energy consumption in China under different future scenarios
    Guo, Siyue
    Yan, Da
    Hu, Shan
    Zhang, Yang
    [J]. ENERGY, 2021, 214 (214)
  • [37] Optimization approaches and climates investigations in NZEB-A review
    Harkouss, Fatima
    Fardoun, Farouk
    Biwole, Pascal Henry
    [J]. BUILDING SIMULATION, 2018, 11 (05) : 923 - 952
  • [38] Identifying practical sustainable retrofit measures for existing high-rise residential buildings in various climate zones through an integrated energy-cost model
    He, Qiong
    Hossain, Md Uzzal
    Ng, S. Thomas
    Augenbroe, Godfried
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 151
  • [39] The human imperative of stabilizing global climate change at 1.5°C
    Hoegh-Guldberg, O.
    Jacob, D.
    Taylor, M.
    Bolanos, T. Guillen
    Bindi, M.
    Brown, S.
    Camilloni, I. A.
    Diedhiou, A.
    Djalante, R.
    Ebi, K.
    Engelbrecht, F.
    Guiot, J.
    Hijioka, Y.
    Mehrotra, S.
    Hope, C. W.
    Payne, A. J.
    Poertner, H. -O.
    Seneviratne, S. I.
    Thomas, A.
    Warren, R.
    Zhou, G.
    [J]. SCIENCE, 2019, 365 (6459) : 1263 - +
  • [40] Extending air temperature setpoints: Simulated energy savings and design considerations for new and retrofit buildings
    Hoyt, Tyler
    Arens, Edward
    Zhang, Hui
    [J]. BUILDING AND ENVIRONMENT, 2015, 88 : 89 - 96