Dose reference level based on size-specific dose estimate (SSDE) and feasibility of deriving effective body diameter using tube current and time product (mAs) for adult chest and abdomen computed tomography (CT) procedures

被引:8
作者
Amalaraj, T. [1 ]
Jeyasugiththan, Jeyasingam [1 ]
Satharasinghe, Duminda [1 ]
Pallewatte, A. S. [2 ]
机构
[1] Univ Colombo, Dept Nucl Sci, Colombo, Sri Lanka
[2] Natl Hosp Sri Lanka, Dept Radiol, Colombo, Sri Lanka
关键词
dose reference level (DRL); computed tomography (CT); size-specific dose estimate (SSDE); effective diameter; mAs; DIAGNOSTIC REFERENCE LEVELS;
D O I
10.1088/1361-6498/acb1bf
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed to establish dose reference level (NDRLSSDE) based on size-specific dose estimate (SSDE) derived using effective diameter (D-eff) for adult chest and abdomen computed tomography (CT) procedures and to explore the feasibility of driving D-eff using the product of tube current and time (mAs). In this retrospective study, dose data, scan parameters and patient body dimensions at the mid-slice level from 14 CT units (out of 63 total) were extracted. Additionally, the mAs values of the axial slice at the same z-location where the diameter measurements were made (mAs(z)) were recorded. Pearson's correlation (r) analysis was used to determine the relationship of D-eff with patient BMI, weight, and mAsz. The NDRLSSDE for the chest and abdomen were 9.72 mGy and 13.4 mGy, respectively. The BMI and body weight were less correlated (r = 0.24 and r = 0.33, respectively) with D-eff. The correlation between mAs(z) and Deff was considerably strong (r = 0.78) and can be used to predict D(eff )accurately. The absolute dose differences between SSDEs calculated using the AAPM-204 method and mAs(z) was less than 1.1 mGy (15%). Therefore, mAs(z) is an efficient parameter to derive D-eff. Further, the direct conversion factors to estimate SSDEs at different locations along the z-direction in the scan region from corresponding mAs and CTDIvol were calculated. The NDRLSSDE suggested in the present study can be used as a reference for size-dependent dose optimisation in Sri Lanka, and existing NDRL based on CTDI(vol )underestimate the average adult CT dose by 36.0% and 39.7% for chest and abdomen regions respectively. The results show that using mAsz to determine SSDE is a simple and practical approach with an accuracy of 95% and 85% for abdomen and chest scans, respectively. However, the obtained linear relationship between Deff and mAs is highly dependent on the ATCM technique and the user-determined noise levels of the scanning protocol. Finally, the phantom study resulted in the strongest correlation (r = 0.99) between the D-w(z) and mAs(z), and the prediction of patient size would be more precise than D-eff method.
引用
收藏
页数:13
相关论文
共 30 条
[1]   Correlation of size-dependent conversion factor and body-mass-index using size-specific dose estimates formalism in CT examinations [J].
Alikhani, Babak ;
Getzin, Tobias ;
Kaireit, Till Frederik ;
Ringe, Kristina Imeen ;
Jamali, Leila ;
Wacker, Frank ;
Werncke, Thomas ;
Raatschen, Hans-Juergen .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 100 :130-134
[2]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[3]  
Amalaraj T, 2021, J RADIOL PROT, DOI [10.1176/ajp.133.1.32, DOI 10.1176/AJP.133.1.32]
[4]  
American College of Radiology, 2018, ACR AAPM SPR PRACT P
[5]   Technological developments of X-ray computed tomography over half a century: User's influence on protocol optimization [J].
Booij, Ronald ;
Budde, Ricardo P. J. ;
Dijkshoorn, Marcel L. ;
van Straten, Marcel .
EUROPEAN JOURNAL OF RADIOLOGY, 2020, 131
[6]  
Boone J.M., 2011, SIZE SPECIFIC DOSE E
[7]   Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates [J].
Boos, Johannes ;
Thomas, Christoph ;
Appel, Elisabeth ;
Klosterkemper, Yan ;
Schleich, Christoph ;
Aissa, Joel ;
Bethge, Oliver Th ;
Antoch, Gerald ;
Kroepil, Patric .
JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) :536-548
[8]   Investigation of American Association of Physicists in Medicine Report 204 Size-specific Dose Estimates for Pediatric CT Implementation [J].
Brady, Samuel L. ;
Kaufman, Robert A. .
RADIOLOGY, 2012, 265 (03) :832-840
[9]  
European Commission and Directorate-General for Environment, 1999, GUIDANCE DIAGNOSTIC
[10]   Diagnostic Reference Ranges for Pediatric Abdominal CT [J].
Goske, Marilyn J. ;
Strauss, Keith J. ;
Coombs, Laura P. ;
Mandel, Keith E. ;
Towbin, Alexander J. ;
Larson, David B. ;
Callahan, Michael J. ;
Darge, Kassa ;
Podberesky, Daniel J. ;
Frush, Donald P. ;
Westra, Sjirk J. ;
Prince, Jeffrey S. .
RADIOLOGY, 2013, 268 (01) :208-218