Design of an X-ray irradiator based on a standard imaging X-ray tube with FLASH dose-rate capabilities for preclinical research

被引:2
|
作者
Espinosa-Rodriguez, A. [1 ,2 ]
Villa-Abaunza, A. [1 ,2 ]
Diaz, N. [1 ,2 ]
Perez-Diaz, M. [4 ]
Sanchez-Parcerisa, D. [1 ,2 ,3 ]
Udias, J. M. [1 ,2 ,3 ]
Ibanez, P. [1 ,2 ,3 ]
机构
[1] Univ Complutense Madrid, Dept Struct Matter Thermal Phys & Elect, CEI Moncloa, Nucl Phys Grp, Madrid, Spain
[2] Univ Complutense Madrid, Dept Struct Matter Thermal Phys & Elect, IPARCOS, CEI Moncloa, Madrid, Spain
[3] Hosp Clin San Carlos, Inst Invest Sanitaria, Madrid, Spain
[4] Sedecal Mol Imaging, Algete, Spain
基金
欧盟地平线“2020”;
关键词
Irradiator; X-rays; FLASH; Preclinical research; RADIATION-THERAPY; FILM DOSIMETRY; RADIOTHERAPY; PLATFORM; TOPAS;
D O I
10.1016/j.radphyschem.2023.110760
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
We propose a new concept of small animal X-ray irradiator based on a conventional imaging X-ray tube for preclinical research. In this work we assessed its feasibility to deliver FLASH dose rates. Our design puts the imaging X-ray tube into a shielded cabinet, which makes the system affordable and suitable to use without disruption in existing laboratories and with minimum regulatory burden. Two conventional 150 kVp X-ray tubes were characterized with Gafchromic films for dose rates and dose uniformity. Monte Carlo simulations were also performed to model the irradiator, and the efficiencies of the tube and dose rates (with and without additional filtration) were calculated and compared with measurements. The feasibility of achieving ultra-high dose rates was determined from the rating charts provided by the manufacturer and measurements. The small animal irradiator proposed in this work was able to deliver conventional dose rate irradiation (0.5-1 Gy/min) at 150 kVp at 20 cm distance with minimum amount of filtration. FLASH irradiations (a 10 Gy dose delivered at >40 Gy/s) were also possible at the maximum capabilities of the tubes by placing the samples at the closest possible distances from the sources. A first prototype has already been built and characterized.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] NEW CAPABILITIES FOR THE AURORA FLASH X-RAY MACHINE
    AGEE, FJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 56-7 : 1063 - 1067
  • [22] Development and Application of Microbeam X-Ray Fluorescence Imaging System Based on Laboratory X-Ray Tube
    Zhang Wen-xing
    Tao Fen
    Liu Yi
    Deng Biao
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2024, 44 (04) : 1061 - 1066
  • [23] A design of metal x-ray tube
    Gingrich, NS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1930, 1 (11): : 691 - 693
  • [24] Bone Cartilage Imaging with X-ray Interferometry using a Practical X-ray Tube
    Kido, Kazuhiro
    Makifuchi, Chiho
    Kiyohara, Junko
    Itou, Tsukasa
    Honda, Chika
    Momose, Atsushi
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [25] Optimization design for insulating structure of a novel flash x-ray tube
    Liang, Chuan
    Xie, Min
    Zhang, Lin-Wen
    Cao, Ke-Feng
    Wang, Meng
    Gaodianya Jishu/High Voltage Engineering, 2008, 34 (02): : 393 - 396
  • [26] Commissioning of a precision preclinical 200 kV x-ray irradiator based on modular adaptations
    Wolf, Lorenz
    Kuess, Peter
    Leitner, Sabine
    Georg, Dietmar
    Knaeusl, Barbara
    MEDICAL PHYSICS, 2025,
  • [27] X-ray tube
    Kravetz, RE
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2001, 96 (04): : 1273 - 1273
  • [28] Design, analysis and testing of x-ray tube for next generation x-ray machines
    Sanganal, Santoshakumar
    Ratnala, Srinivas Rao
    Gouda, P. S. Shivakumar
    INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS AND MANUFACTURING APPLICATIONS (ICONAMMA-2016), 2016, 149
  • [29] Design, hard x-ray source characterization and applications of a plasma focus tailored for flash hard x-ray imaging
    Knoblauch, P.
    Di Lorenzo, F.
    Raspa, V.
    Clausse, A.
    Moreno, C.
    PHYSICA SCRIPTA, 2008, T131
  • [30] X-ray imaging using a tunable coherent X-ray source based on parametric X-ray radiation
    Hayakawa, Y.
    Takahashi, Y.
    Kuwada, T.
    Sakae, T.
    Tanaka, T.
    Nakao, K.
    Nogami, K.
    Inagaki, M.
    Hayakawa, K.
    Sato, I.
    JOURNAL OF INSTRUMENTATION, 2013, 8