PK Modeling of L-4-Boronophenylalanine and Development of Bayesian Predictive Platform for L-4-Boronophenylalanine PKs for Boron Neutron Capture Therapy

被引:1
作者
Kim, Woohyoung [1 ]
Won, Ji Yeong [1 ]
Yi, Jungyu [2 ]
Choi, Seung Chan [3 ]
Lee, Sang Min [3 ]
Mun, Kyungran [3 ]
Lim, Hyeong-Seok [3 ]
机构
[1] Dawonmedax Co Ltd, Clin Dev, Seoul 06735, South Korea
[2] Dawonmedax Co Ltd, Treatment Planning Syst, Seoul 06735, South Korea
[3] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Clin Pharmacol & Therapeut, Pungnap-2-dong, Seoul 05505, South Korea
关键词
boronophenylalanine; boron neutron capture therapy; PK modeling; nonlinear mixed effect modeling; GLIOBLASTOMA-MULTIFORME; B-10; CONCENTRATION; BORONOPHENYLALANINE; BIODISTRIBUTION; TISSUE; TRIAL; TUMOR; NECK; HEAD; BNCT;
D O I
10.3390/ph17030301
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
L-4-[(10B)]Boronophenylalanine (BPA) is an amino acid analogue with a boron-10 moiety. It is most widely used as a boron carrier in boron neutron capture therapy. In this study, a Bayesian predictive platform of blood boron concentration based on a BPA pharmacokinetic (PK) model was developed. This platform is user-friendly and can predict the individual boron PK and optimal time window for boron neutron capture therapy in a simple way. The present study aimed to establish a PK model of L-4-boronophenylalanine and develop a Bayesian predictive platform for blood boron PKs for user-friendly estimation of boron concentration during neutron irradiation of neutron capture therapy. Whole blood boron concentrations from seven previous reports were graphically extracted and analyzed using the nonlinear mixed-effects modeling (NONMEM) approach. Model robustness was assessed using nonparametric bootstrap and visual predictive check approaches. The visual predictive check indicated that the final PK model is able to adequately predict observed concentrations. The Shiny package was used to input real-time blood boron concentration data, and during the following irradiation session blood boron was estimated with an acceptably short calculation time for the determination of irradiation time. Finally, a user-friendly Bayesian estimation platform for BPA PKs was developed to optimize individualized therapy for patients undergoing BNCT.
引用
收藏
页数:13
相关论文
共 26 条
[1]   Proton therapy for head and neck cancers [J].
Blanchard, P. ;
Frank, S. J. .
CANCER RADIOTHERAPIE, 2017, 21 (6-7) :515-520
[2]  
Burnet Neil G, 2004, Cancer Imaging, V4, P153, DOI 10.1102/1470-7330.2004.0054
[3]   Boron neutron capture therapy for glioblastoma multiforme: Interim results from the Phase I/II dose-escalation studies [J].
Chanana, AD ;
Capala, J ;
Chadha, M ;
Coderre, JA ;
Diaz, AZ ;
Elowitz, EH ;
Iwai, J ;
Joel, DD ;
Liu, HGB ;
Ma, RM ;
Pendzick, N ;
Peress, NS ;
Shady, MS ;
Slatkin, DN ;
Tyson, GW ;
Wielopolski, L .
NEUROSURGERY, 1999, 44 (06) :1182-1192
[4]   Biodistribution of boronophenylalanine in patients with glioblastoma multiforme: Boron concentration correlates with tumor cellularity [J].
Coderre, JA ;
Chanana, AD ;
Joel, DD ;
Elowitz, EH ;
Micca, PL ;
Nawrocky, MM ;
Chadha, M ;
Gebbers, JO ;
Shady, M ;
Peress, NS ;
Slatkin, DN .
RADIATION RESEARCH, 1998, 149 (02) :163-170
[5]   The radiation biology of boron neutron capture therapy [J].
Coderre, JA ;
Morris, GM .
RADIATION RESEARCH, 1999, 151 (01) :1-18
[6]   Biodistribution of p-boronophenylalanine in patients with glioblastoma multiforme for use in boron neutron capture therapy [J].
Elowitz, EH ;
Bergland, RM ;
Coderre, JA ;
Joel, DD ;
Chadha, M ;
Chanana, AD .
NEUROSURGERY, 1998, 42 (03) :463-468
[7]   BORON NEUTRON-CAPTURE THERAPY OF MALIGNANT-MELANOMA USING B-10-PARABORONOPHENYLALANINE WITH SPECIAL REFERENCE TO EVALUATION OF RADIATION-DOSE AND DAMAGE TO THE NORMAL SKIN [J].
FUKUDA, H ;
HIRATSUKA, J ;
HONDA, C ;
KOBAYASHI, T ;
YOSHINO, K ;
KARASHIMA, H ;
TAKAHASHI, J ;
ABE, Y ;
KANDA, K ;
ICHIHASHI, M ;
MISHIMA, Y .
RADIATION RESEARCH, 1994, 138 (03) :435-442
[8]   FBPA PET in boron neutron capture therapy for cancer: prediction of 10B concentration in the tumor and normal tissue in a rat xenograft model [J].
Hanaoka, Kohei ;
Watabe, Tadashi ;
Naka, Sadahiro ;
Kanai, Yasukazu ;
Ikeda, Hayato ;
Horitsugi, Genki ;
Kato, Hiroki ;
Isohashi, Kayako ;
Shimosegawa, Eku ;
Hatazawa, Jun .
EJNMMI RESEARCH, 2014, 4
[9]   Advances in Radiation Oncology: What to Consider [J].
Hegde, John V. ;
Chen, Allen M. ;
Chin, Robert K. .
OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 2017, 50 (04) :755-+
[10]  
International Atomic Energy Agency, 2023, Advances in Boron Neutron Capture Therapy, P29