Charging Current Characteristics and Effect of Casing Material in Wireless Recharging of Active Implantable Medical Devices Using Transcutaneous Energy Transfer System

被引:0
作者
Nair, Sarath S. [1 ]
Muniyandi, Manivannan [2 ]
Nagesh, D. S. [1 ]
Muraleedharan, C., V [1 ]
Joseph, Roy [1 ]
Harikrishnan, S. [3 ]
机构
[1] SCTIMST, Dept Med Devices Engn, Biomed Technol Wing, Thiruvananthapuram, India
[2] Indian Inst Technol, Dept Appl Mech, Madras, India
[3] SCTIMST, Dept Cardiol, Thiruvananthapuram, India
来源
PROGRESS IN ELECTROMAGNETICS RESEARCH M | 2023年 / 122卷
关键词
ARTIFICIAL-HEART; TRANSMISSION; BATTERIES;
D O I
10.2528/PIERM23082001
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Batteries inside an active implantable medical device (AIMD) need to be replaced every few years. However, rechargeable batteries can enhance the life of such devices to a large extent. Transcutaneous Energy Transfer System (TETS) is a promising method for recharging these batteries inside medical devices. These devices are generally made of metal casings to avoid fluid ingress and provide better mechanical strength. However, the metal cases when being present in the path of electromagnetic energy induces eddy current thus producing excessive temperature rise due to thermal loss. Thus, the selection of an interface casing material plays a significant role in the performance of the wireless recharging. In this paper, the performance of a transcutaneous energy transfer system for recharging an AIMD with different axial gaps and casing materials is reported. The effect of these variations on the output voltage, recharge current, and efficiency of operation was quantified. It has been found that, with TETS the charging current of 0.3 A to 0.5 A can be obtained to charge the implanted battery within 180 minutes. It was found that the induced voltage in the secondary coil is substantially reduced with the presence of titanium casing compared to epoxy encapsulation. Thermal studies were performed with titanium casing material of various thicknesses. The casing temperature rose to above 70 degrees C within the first 10 minutes for 0.5 mm thickness and within 50 minutes in the case of 0.25 mm. With epoxy encapsulation, the casing temperature rose to only 30 degrees C. The charging voltage of 5 V and charging current of more than 0.3 A were obtained with epoxy encapsulation. A polymeric material casing or epoxy encapsulation is the best choice in the interface region to get a high recharging current in the case of wireless recharging of implantable medical devices. With the proposed design modification, wireless energy transfer and recharging implanted batteries shall be done in a more energy-efficient manner with less thermal damage to nearby tissues.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 35 条
  • [11] A Low-Frequency Versatile Wireless Power Transfer Technology for Biomedical Implants
    Jiang, Hao
    Zhang, Junmin
    Lan, Di
    Chao, Kelvin K.
    Liou, Shyshenq
    Shahnasser, Hamid
    Fechter, Richard
    Hirose, Shinjiro
    Harrison, Michael
    Roy, Shuvo
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2013, 7 (04) : 526 - 535
  • [12] An energy transmission system for an artificial heart using leakage inductance compensation of transcutaneous transformer
    Joung, GB
    Cho, BH
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 1998, 13 (06) : 1013 - 1022
  • [13] Joung YH, 2013, INT NEUROUROL J, V17, P98
  • [14] Energy harvesting by implantable abiotically catalyzed glucose fuel cells
    Kerzenmacher, S.
    Ducree, J.
    Zengerle, R.
    von Stetten, F.
    [J]. JOURNAL OF POWER SOURCES, 2008, 182 (01) : 1 - 17
  • [15] A resonant current-mode wireless power transfer for implantable medical devices: an overview
    Kim, Jong-Hun
    Hassan, Najam ul
    Lee, Seung-Ju
    Jung, Yeon-Woo
    Shin, Se-Un
    [J]. BIOMEDICAL ENGINEERING LETTERS, 2022, 12 (03) : 229 - 238
  • [16] Knecht O, 2014, IEEE W CONTR MODEL
  • [17] High-Efficiency Transcutaneous Energy Transfer for Implantable Mechanical Heart Support Systems
    Knecht, Oliver
    Bosshard, Roman
    Kolar, Johann W.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (11) : 6221 - 6236
  • [18] Majerus S, 2014, 2014 IEEE DALLAS CIRCUITS AND SYSTEMS CONFERENCE (IEEE DCAS 2014)
  • [19] Mazzilli F., 2012, 2012 IEEE International Symposium on Circuits and Systems - ISCAS 2012, P2865, DOI 10.1109/ISCAS.2012.6271911
  • [20] Applications of Wireless Power Transfer in Medicine: State-of-the-Art Reviews
    Moore, Julian
    Castellanos, Sharon
    Xu, Sheng
    Wood, Bradford
    Ren, Hongliang
    Tse, Zion Tsz Ho
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (01) : 22 - 38