Oscillometric measurement of the ankle-brachial index and the estimated carotid-femoral pulse wave velocity improves the sensitivity of an automated device in screening peripheral artery disease

被引:3
|
作者
Fendrik, Krisztina [1 ]
Biro, Katalin [1 ]
Endrei, Dora [1 ]
Koltai, Katalin [1 ]
Sandor, Barbara [2 ]
Toth, Kalman [2 ]
Kesmarky, Gabor [1 ]
机构
[1] Univ Pecs, Div Angiol, Dept Med 1, Clin Ctr,Med Sch, Pecs, Hungary
[2] Univ Pecs, Div Cardiol, Dept Med 1, Med Sch,Clin Ctr, Pecs, Hungary
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2023年 / 10卷
关键词
peripheral artery disease; PAD; screening; oscillometric; BOSO; BLOOD-PRESSURE; RISK-FACTORS; ALL-CAUSE; STIFFNESS; PREVALENCE; ASSOCIATION; VALIDATION; MORTALITY; CONSENSUS; CORONARY;
D O I
10.3389/fcvm.2023.1275856
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aimsTo overcome the time and personnel constraints of the Doppler method, automated, four-limb blood pressure monitors were recently developed. Their additional functions, such as measuring the estimated carotid-femoral pulse wave velocity (ecfPWV), have been, thus far, less studied. We aimed to compare the sensitivity and specificity of different ankle-brachial index (ABI), toe-brachial index (TBI), and ecfPWV measurement methodologies to evaluate their contribution to peripheral artery disease (PAD) screening.MethodsAmong 230 patients (mean age 64 +/- 14 years), ABI measurements were performed using a Doppler device and a manual sphygmomanometer. The Doppler ABI was calculated by taking the higher, while the modified Doppler ABI by taking the lower systolic blood pressure of the two ankle arteries as the numerator, and the higher systolic blood pressure of both brachial arteries as the denominator. The automated ABI measurement was carried out using an automatic BOSO ABI-system 100 PWV device, which also measured ecfPWV. TBI was obtained using a laser Doppler fluxmeter (Periflux 5000) and a photoplethysmographic device (SysToe). To assess atherosclerotic and definitive PAD lesions, vascular imaging techniques were used, including ultrasound in 160, digital subtraction angiography in 66, and CT angiography in four cases.ResultsROC analysis exhibited a sensitivity/specificity of 70.6%/98.1% for the Doppler ABI (area under the curve, AUC = 0.873), 84.0%/94.4% for the modified Doppler ABI (AUC = 0.923), and 61.5%/97.8% for the BOSO ABI (AUC = 0.882) at a cutoff of 0.9. Raising the cutoff to 1.0 increased the sensitivity of BOSO to 80.7%, with the specificity decreasing to 79.1%. The ecfPWV measurement (AUC = 0.896) demonstrated a 63.2%/100% sensitivity/specificity in predicting atherosclerotic lesions at a cutoff of 10 m/s. Combining BOSO ABI and ecfPWV measurements recognized 89.5% of all PAD limbs.ConclusionThe combined BOSO ABI and ecfPWV measurements may help select patients requiring further non-invasive diagnostic evaluation for PAD. The user-friendly feasibility may make it suitable for screening large populations.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Brachial-ankle vs carotid-femoral pulse wave velocity as a determinant of cardiovascular structure and function
    Yu, W-C
    Chuang, S-Y
    Lin, Y-P
    Chen, C-H
    JOURNAL OF HUMAN HYPERTENSION, 2008, 22 (01) : 24 - 31
  • [22] Quantification of the Interrelationship between Brachial-Ankle and Carotid-Femoral Pulse Wave Velocity in a Workplace Population
    Cheng, Yi-Bang
    Li, Yan
    Sheng, Chang-Sheng
    Huang, Qi-Fang
    Wang, Ji-Guang
    PULSE, 2015, 3 (3-4) : 253 - 262
  • [23] Determination of lower extremity peripheral artery disease: the role for automated oscillometric measurement of ankle brachial index in Nigerians
    Umuerri, Ejiroghene M.
    CIRCULATION, 2012, 125 (19) : E795 - E795
  • [24] Ankle-Brachial Index Screening and Improving Peripheral Artery Disease Detection and Outcomes
    McDermott, Mary M.
    Criqui, Michael H.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2018, 320 (02): : 143 - 145
  • [25] Screening for Peripheral Artery Disease and Cardiovascular Disease Risk Assessment with the Ankle-Brachial Index
    Mills, Justin
    Duffy, Martha
    AMERICAN FAMILY PHYSICIAN, 2018, 98 (12) : 754 - 755
  • [26] Cardio-ankle vascular index and carotid-femoral pulse wave velocity: limits and strengths
    Grillo, Andrea
    Salvi, Paolo
    JOURNAL OF HYPERTENSION, 2018, 36 (04) : 759 - 764
  • [27] 2.1 A Method for the Measurement of Pressure Sensitivity of Carotid-Femoral Pulse Wave Velocity in Humans
    Mark Butlin
    Alberto Avolio
    Artery Research, 2015, 12 (1) : 40 - 41
  • [28] Association of pulse wave velocity and pressure wave reflection with the ankle-brachial pressure index in Japanese men not suffering from peripheral artery disease
    Takahashi, Takamichi
    Tomiyama, Hirofumi
    Aboyans, Victor
    Kumai, Kento
    Nakano, Hiroki
    Fujii, Masatsune
    Shiina, Kazuki
    Matsumoto, Chisa
    Yamashina, Akira
    Chikamori, Taishiro
    ATHEROSCLEROSIS, 2021, 317 : 29 - 35
  • [29] The Vicorder device compared with SphygmoCor in the assessment of carotid-femoral pulse wave velocity in patients with peripheral arterial disease
    Shahin, Yousef
    Barakat, Hashem
    Barnes, Rachel
    Chetter, Ian
    HYPERTENSION RESEARCH, 2013, 36 (03) : 208 - 212
  • [30] Oscillometric measurement of ankle-brachial index in patients with suspected peripheral vascular disease: comparison with Doppler method
    Diehm, Nicolas
    Dick, Florian
    Czuprin, Carsten
    Lawall, Holger
    Baumgartner, Iris
    Diehm, Curt
    SWISS MEDICAL WEEKLY, 2009, 139 (25-26) : 357 - 363