Oscillometric measurement of the ankle-brachial index and the estimated carotid-femoral pulse wave velocity improves the sensitivity of an automated device in screening peripheral artery disease

被引:3
|
作者
Fendrik, Krisztina [1 ]
Biro, Katalin [1 ]
Endrei, Dora [1 ]
Koltai, Katalin [1 ]
Sandor, Barbara [2 ]
Toth, Kalman [2 ]
Kesmarky, Gabor [1 ]
机构
[1] Univ Pecs, Div Angiol, Dept Med 1, Clin Ctr,Med Sch, Pecs, Hungary
[2] Univ Pecs, Div Cardiol, Dept Med 1, Med Sch,Clin Ctr, Pecs, Hungary
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2023年 / 10卷
关键词
peripheral artery disease; PAD; screening; oscillometric; BOSO; BLOOD-PRESSURE; RISK-FACTORS; ALL-CAUSE; STIFFNESS; PREVALENCE; ASSOCIATION; VALIDATION; MORTALITY; CONSENSUS; CORONARY;
D O I
10.3389/fcvm.2023.1275856
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aimsTo overcome the time and personnel constraints of the Doppler method, automated, four-limb blood pressure monitors were recently developed. Their additional functions, such as measuring the estimated carotid-femoral pulse wave velocity (ecfPWV), have been, thus far, less studied. We aimed to compare the sensitivity and specificity of different ankle-brachial index (ABI), toe-brachial index (TBI), and ecfPWV measurement methodologies to evaluate their contribution to peripheral artery disease (PAD) screening.MethodsAmong 230 patients (mean age 64 +/- 14 years), ABI measurements were performed using a Doppler device and a manual sphygmomanometer. The Doppler ABI was calculated by taking the higher, while the modified Doppler ABI by taking the lower systolic blood pressure of the two ankle arteries as the numerator, and the higher systolic blood pressure of both brachial arteries as the denominator. The automated ABI measurement was carried out using an automatic BOSO ABI-system 100 PWV device, which also measured ecfPWV. TBI was obtained using a laser Doppler fluxmeter (Periflux 5000) and a photoplethysmographic device (SysToe). To assess atherosclerotic and definitive PAD lesions, vascular imaging techniques were used, including ultrasound in 160, digital subtraction angiography in 66, and CT angiography in four cases.ResultsROC analysis exhibited a sensitivity/specificity of 70.6%/98.1% for the Doppler ABI (area under the curve, AUC = 0.873), 84.0%/94.4% for the modified Doppler ABI (AUC = 0.923), and 61.5%/97.8% for the BOSO ABI (AUC = 0.882) at a cutoff of 0.9. Raising the cutoff to 1.0 increased the sensitivity of BOSO to 80.7%, with the specificity decreasing to 79.1%. The ecfPWV measurement (AUC = 0.896) demonstrated a 63.2%/100% sensitivity/specificity in predicting atherosclerotic lesions at a cutoff of 10 m/s. Combining BOSO ABI and ecfPWV measurements recognized 89.5% of all PAD limbs.ConclusionThe combined BOSO ABI and ecfPWV measurements may help select patients requiring further non-invasive diagnostic evaluation for PAD. The user-friendly feasibility may make it suitable for screening large populations.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] The Accuracy and Reliability of Automated Oscillometric Measurement of Ankle-Brachial Index in the Diagnosis of Peripheral Artery Disease
    Fu, Guanqi
    Jiang, Rui
    Qian, Cheng
    Liu, Zhengli
    Kong, Jie
    Gong, Maofeng
    Wang, Tao
    He, Xu
    ANNALS OF VASCULAR SURGERY, 2024, 100 : 1 - 7
  • [2] Automated oscillometric measurement of the ankle-brachial index in patients with coronary artery disease
    Sinski, Maciej
    Styczynski, Grzegorz
    Szmigielski, Cezary
    HYPERTENSION RESEARCH, 2013, 36 (01) : 25 - 28
  • [3] Diagnostic accuracy of automated oscillometric determination of the ankle-brachial index in peripheral artery disease
    Hageman, David
    van den Houten, Marijn M. L.
    Pesser, Niels
    Gommans, Lindy N. M.
    Scheltinga, Marc R. M.
    Teijink, Joep A. W.
    JOURNAL OF VASCULAR SURGERY, 2021, 73 (02) : 652 - 660
  • [4] Accuracy of oscillometric determination of the ankle-brachial index as screening method for peripheral artery disease
    Campens, Laurence
    De Backer, Tine
    Simoens, Steven
    Vermassen, Frank
    Coeman, Mathieu
    De Pauw, Michel
    De Bacquer, Dirk
    ACTA CARDIOLOGICA, 2012, 67 (01) : 136 - 137
  • [5] Oscillometric Carotid to Femoral Pulse Wave Velocity Estimated With the Vicorder Device
    Mueller, Jan
    Oberhoffer, Renate
    Barta, Christiane
    Hulpke-Wette, Martin
    Hager, Alfred
    JOURNAL OF CLINICAL HYPERTENSION, 2013, 15 (03): : 176 - 179
  • [6] The Relationship of Pulse Wave Velocity, Ankle-Brachial Index, and Coronary Artery Disease
    He, Qing
    Mao, Wen
    CIRCULATION, 2010, 122 (02) : E34 - E34
  • [7] 12.15: Accuracy of Oscillometric Determination of the Ankle-Brachial Index as Screening Method for Peripheral Artery Disease
    L. Campens
    T. De Backer
    S. Simoens
    F. Vermassen
    M. Coeman
    M. De Pauw
    D. De Bacquer
    Artery Research, 2011, 5 (4) : 204 - 204
  • [8] Determinants of Brachial-Ankle Pulse Wave Velocity and Carotid-Femoral Pulse Wave Velocity in Healthy Koreans
    Jang, Shin Yi
    Ju, Eun Young
    Huh, Eun Hee
    Kim, Jung Hyun
    Kim, Duk-Kyung
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2014, 29 (06) : 798 - 804
  • [9] Pediatric reference values of carotid-femoral pulse wave velocity determined with an oscillometric device
    Fischer, Dagmar-Christiane
    Schreiver, Corinna
    Heimhalt, Mirjam
    Noerenberg, Anja
    Haffner, Dieter
    JOURNAL OF HYPERTENSION, 2012, 30 (11) : 2159 - 2167
  • [10] AUTOMATED BRACHIAL-ANKLE VERSUS CAROTID-FEMORAL PULSE WAVE VELOCITY: COMPARISON AND VALIDATION VERSUS CAROTID DAMAGE
    Kollias, A.
    Kyriakoulis, K.
    Gravvani, A.
    Anagnostopoulos, I.
    Stergiou, G. S.
    JOURNAL OF HYPERTENSION, 2019, 37 : E312 - E312