Influence of high fluence heavy ion irradiation on the performance of single crystal diamond detectors

被引:1
|
作者
Wang, X. [1 ]
Li, Z. [1 ]
Li, R. [1 ]
Lu, Z. [1 ]
Chen, C. [1 ]
Liu, F. [1 ]
Ma, S. [1 ]
Wu, G. [2 ]
Li, H. [1 ]
机构
[1] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
[2] Lanzhou Jiaotong Univ, Coll Math & Phys, Lanzhou 750000, Peoples R China
关键词
Diamond Detectors; Heavy-ion detectors; Radiation-hard detectors; Solid state detectors; CVD-DIAMOND; CHARGE COLLECTION; ENERGY; MOBILITY;
D O I
10.1088/1748-0221/18/11/P11014
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Radiation detectors based on diamond are highly favored for particle physics research due to their superior radiation hardness. In this work, the performance of single crystal diamond detectors under high fluence heavy ion radiation has been investigated. After irradiation by Fe13+ and Xe20+ ion beams with a high particle fluence of 1.2 x 10(15) cm(-2), the properties of unirradiated and irradiated intrinsic single crystal chemical vapor deposition (CVD) diamond detectors are compared by means of the spectroscopic energy resolution, charge collection efficiency (CCE), mobility-lifetime (mu tau.) product and time response using a Am-241 alpha (alpha) particle source. The experimental results of the unirradiated sample with respect to I-V dark current levels, showed an ohmic behaviour of the Al and Cr/Au contact, CCE of 100%, fast response with a rise time of 750 ps and a fall time of 600 ps as well as drift velocities of 6.67 x 10(4) m/s and 4.72 x 10(4) m/s for holes and electrons respectively. In the case of the irradiated samples, the CCE, mu tau product and time response pulse amplitude of holes and electrons were all degraded, indicating that high density trappings for both kinds of carriers were created under the diamond crystal surface and the trapping probability of holes and electrons was equal, which was different from the previous reports in the literature where only higher trapping probability of holes were observed under heavy ions irradiation. In particular, the spectroscopic performance as well as mu tau product of holes and electrons in Fe13+ irradiated sample decreased more than those in Xe20+ irradiated sample, which implied that the recombination of electrons and holes increased in Fe13+ irradiated sample with greater penetration depth than that in Xe20+ irradiated sample when radiation fluence was up to 1015 cm(-2), despite the lower density of lattice vacancies in Fe13+ irradiated sample. Moreover, the rise time of holes was slightly different, but the drift velocity was basically the same as that of the unirradiated sample, and so was that of the electrons. Anyway, the presented results showed that the diamond detectors irradiated by heavy ions at a high fluence of 1015 cm(-2) still retained their good spectroscopic and very fast time response properties.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Development of large area polycrystalline diamond detectors for fast timing application of high-energy heavy-ion beams
    Schirru, F.
    Singh, B. S. Nara
    Scruton, L.
    Bentley, M. A.
    Fox, S. P.
    Lohstroh, A.
    Sellin, P. J.
    Banu, A.
    McCleskey, M.
    Roeder, B. T.
    Simmons, E.
    Alharbi, A. A.
    Trache, L.
    Freer, M.
    Parker, D.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [12] Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring
    Curtoni, S.
    Gallin-Martel, M-L
    Marcatili, S.
    Abbassi, L.
    Bes, A.
    Bosson, G.
    Collot, J.
    Crozes, T.
    Dauvergne, D.
    De Nolf, W.
    Everaere, P.
    Gallin-Martel, L.
    Ghimouz, A.
    Haddad, F.
    Hoarau, C.
    Hostachy, J-Y
    Koumeir, C.
    Lacoste, A.
    Metivier, V
    Morse, J.
    Motte, J-F
    Muraz, J-F
    Poirier, F.
    Rarbi, F. E.
    Rossetto, O.
    Salome, M.
    Servagent, N.
    Testa, E.
    Yamouni, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1015
  • [13] Single crystal diamond detectors grown by chemical vapor deposition
    Tuve, C.
    Angelone, M.
    Bellini, V.
    Balducci, A.
    Donato, M. G.
    Faggio, G.
    Marinelli, M.
    Messina, G.
    Milani, E.
    Morgada, M. E.
    Pillon, M.
    Potenza, R.
    Pucella, G.
    Russo, G.
    Santangelo, S.
    Scoccia, M.
    Sutera, C.
    Tucciarone, A.
    Verona-Rinati, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 570 (02) : 299 - 302
  • [14] Influence of helium ion irradiation on the structure and strength of diamond
    Chen, Ming
    Best, James P.
    Shorubalko, Ivan
    Michler, Johann
    Spolenak, Ralph
    Wheeler, Jeffrey M.
    CARBON, 2020, 158 : 337 - 345
  • [15] Influence of high energy ion irradiation on the field emission characteristics of CVD diamond films
    Koinkar, PM
    Khairnar, RS
    Khan, SA
    Gupta, RP
    Avasthi, DK
    More, MA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 244 (01) : 217 - 220
  • [16] Time response of 50 μm thickness single crystal diamond detectors
    Duenas, J. A.
    Mora, J. M.
    Traeger, M.
    Galbiati, A.
    Martel, I.
    Berdermann, E.
    DIAMOND AND RELATED MATERIALS, 2015, 55 : 144 - 148
  • [17] Comparison of single crystal diamond TOF detectors in planar and transverse configuration
    Verona, C.
    Marinelli, M.
    Palomba, S.
    Verona-Rinati, G.
    Salvadori, M.
    Consoli, F.
    Cipriani, M.
    Antici, P.
    Migliorati, M.
    Bisesto, F.
    Pompili, R.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (09)
  • [18] Prototyping and performance study of a single crystal diamond detector for operation at high temperatures
    Kumar, Amit
    Kumar, Arvind
    Topkar, Anita
    Das, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 858 : 12 - 17
  • [19] Development of NPA array using single crystal CVD diamond detectors
    Kamio, S.
    Fujiwara, Y.
    Ogawa, K.
    Isobe, M.
    Seki, R.
    Nuga, H.
    Nishitani, T.
    Osakabe, M.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [20] High-Pressure High-Temperature Single-Crystal Diamond Type IIa Characterization for Particle Detectors
    Chernykh, Sergey V.
    Chernykh, Alexey V.
    Tarelkin, Sergey A.
    Kondakov, Mikhail N.
    Shcherbachev, Kirill D.
    Trifonova, Ekaterina V.
    Drozdova, Taisia E.
    Troschiev, Sergey Yu.
    Prikhodko, Dmitry D.
    Glybin, Yury N.
    Chubenko, Alexander P.
    Britvich, Gennady I.
    Kiselev, Dmitry A.
    Polushin, Nikolay I.
    Rabinovich, Oleg I.
    Didenko, Sergey I.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2020, 217 (08):