ENERGETIC AND ENTROPY ANALYSIS OF A NOVEL TRANSCRITICAL CO2 TWO-STAGE COMPRESSION/EJECTOR REFRIGERATION CYCLE FOR SHIPBOARD COLD CHAMBER

被引:1
作者
Yang, Dazhang [1 ,2 ,3 ,4 ]
Li, Yang [1 ,2 ,3 ,4 ]
Xie, Jing [1 ,2 ,3 ,4 ]
Wang, Jinfeng [1 ,2 ,3 ,4 ]
机构
[1] Shanghai Ocean Univ, Coll Food Sci & Technol, Shanghai, Peoples R China
[2] Profess Technol Serv Platform Cold Chain Equipment, Shanghai, Peoples R China
[3] Shanghai Ocean Univ, Expt Teaching Demonstrat Ctr Food Sci & Engn, Shanghai, Peoples R China
[4] Minist Agr, Qual Supervis, Inspect & Testing Ctr Cold Storage & Refrigerat Eq, Shanghai, Peoples R China
来源
THERMAL SCIENCE | 2023年 / 27卷 / 4A期
关键词
energetic analysis; entropy analysis; COP; transcritical CO2 refrigeration cycle; two-phase ejector; GENERATION; PERFORMANCE; EXERGY; SYSTEM;
D O I
10.2298/TSCI220702181Y
中图分类号
O414.1 [热力学];
学科分类号
摘要
The adverse effects of global warming and climate change require critical measures for marine refrigeration technology because of its impact on GHG emissions. A novel transcritical CO2 two-stage compression/ejector refrigeration cycle for shipboard cold chamber is proposed in this research. A comparative analysis was conducted between the basic transcritical CO2 two-stage compression cycle and the cycle equipped with a two-phase ejector considering the COP. Meanwhile, the refrigeration cycle was analyzed using entropy analysis to elucidate the distribution of irreversible losses in each component of the two-stage compression/ejector refrigeration cycle, and the effects of system parameters such as the evaporating and gas cooler outlet temperatures as well as the intermediate and discharge pressures on the cycle were investigated. The results showed that the ejector had the largest power capability loss, accounting for 26.95 % of the overall system, which is followed by the low pressure compressor with 26.06%. The COP of basic and ejector system significantly increase as the gas cooler outlet temperature and intermediate pressure decrease as well as the evaporating temperature increases. Furthermore, the entropy production of the system components decreases gradually with increasing evaporating temperature, with the greatest reduction in the ejector. In addition, the entropy production of the two-phase ejector remains constant with the increase of the high pressure side discharge pressure and gas cooler outlet temperature.
引用
收藏
页码:2607 / 2621
页数:15
相关论文
共 21 条
[1]   MODELS FOR OPTIMUM THERMO-ECOLOGICAL CRITERIA OF ACTUAL THERMAL CYCLES [J].
Acikkalp, Emin .
THERMAL SCIENCE, 2013, 17 (03) :915-930
[2]   Thermodynamic analyses on an ejector enhanced CO2 transcritical heat pump cycle with vapor-injection [J].
Bai, Tao ;
Yan, Gang ;
Yu, Jianlin .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 58 :22-34
[3]   Performance analysis of an ejector-assisted two-stage evaporation single-stage vapor-compression cycle [J].
Cao, Xiang ;
Liang, Xingyu ;
Shao, Liangliang ;
Zhang, Chunlu .
APPLIED THERMAL ENGINEERING, 2022, 205
[4]   Evaluation of the ejector refrigeration system with environmentally friendly working fluids from energy, conventional exergy and advanced exergy perspectives [J].
Chen, Jianyong ;
Zhu, Kangda ;
Huang, Yisheng ;
Chen, Ying ;
Luo, Xianglong .
ENERGY CONVERSION AND MANAGEMENT, 2017, 148 :1208-1224
[5]   Design and Thermodynamic Analysis of Waste Heat-Driven Zeolite-Water Continuous-Adsorption Refrigeration and Heat Pump System for Ships [J].
Ezgi, Cuneyt .
ENERGIES, 2021, 14 (03)
[6]   Improvement of the wet steam ejector performance in a refrigeration cycle via changing the ejector geometry by a novel EEC (Entropy generation, Entrainment ratio, and Coefficient of performance) method [J].
Foroozesh, Farzaneh ;
Khoshnevis, Abdolamir Bak ;
Lakzian, Esmail .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 110 :248-261
[7]   RESEARCH NOTE ON A PARABOLIC HEAT-BALANCE INTEGRAL METHOD WITH UNSPECIFIED EXPONENT: An Entropy Generation Approach in Optimal Profile Determination [J].
Hristov, Jordan .
THERMAL SCIENCE, 2009, 13 (02) :49-59
[8]  
Ji Y., 2008, Cryogenics and Superconductivity, V36, P12
[9]   Numerical Investigation on the Performance of Two-Throat Nozzle Ejectors with Different Mixing Chamber Structural Parameters [J].
Jia, Fatong ;
Yang, Dazhang ;
Xie, Jing .
ENERGIES, 2021, 14 (21)
[10]  
Liang Y, 2020, International Journal of Refrigeration, V118, P70