Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures

被引:1
作者
Kotler, Joshua A. [1 ,5 ]
Zuppke, Julia N. [2 ]
Abraham, Vivek M. [2 ]
Sanville, Jennifer A. [2 ]
Nabet, Austin C. [2 ]
Carofino, Bradley [3 ]
Gardner, Michael J. [4 ]
Smith, Christopher S. [2 ]
机构
[1] III Marine Expeditionary Force, Marine Logist Grp 3, Med Battal 3, Okinawa, Japan
[2] Naval Med Readiness & Training Ctr, Bone & Joint Sports Med Inst, Portsmouth, VA USA
[3] Atlantic Orthopaed Specialists, Virginia Beach, VA USA
[4] Stanford Univ, Dept Orthopaed Surg, Redwood City, CA USA
[5] III MEF, MLG 3, Med Battal 3, Unit 38404, FPO,AP 96604-8404, Okinawa, Japan
关键词
proximal humerus fracture; internal fixation; biomechanics; locking plates; bending; torsion; medial calcar plating; FIXATION; LOCKING; SUPPORT; EPIDEMIOLOGY; REDUCTION; PARALLEL; FRAGMENT;
D O I
10.1097/BOT.0000000000002619
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective:Medial calcar buttress plating combined with lateral locked plating is biomechanically tested against isolated lateral locked plating in synthetic humeri models for the treatment of proximal humerus fractures.Methods:Proximal humerus fractures (OTA/AO type 11-A2.1) were manufactured in 10 pairs of Sawbones humeri models (Sawbones, Pacific Research Laboratories, Vashon Island, WA). Specimen were randomly assigned and instrumented with either medial calcar buttress plating combined with lateral locked plating (CP) or isolated lateral locked plating (LP). Nondestructive torsional and axial load tests were performed to evaluate construct stiffness. Large-cycle axial tests were conducted followed by destructive ramp-to-failure tests. Cyclic stiffness was compared in both nondestructive and ultimate failure loads. Failure displacement was recorded and compared between groups.Results:The addition of medial calcar buttress plating to lateral locked plating constructs significantly increased the axial (P < 0.01) and torsional (P < 0.01) stiffness of the construct compared with isolated lateral locked plating by 95.56% and 37.46%, respectively. All models demonstrated greater axial stiffness (P < 0.01) after 5000 cycles of axial compression, not dependent on the fixation method. During destructive testing, the CP construct withstood 45.35% larger load (P < 0.01) and congruently exhibited 58% less humeral head displacement (P = 0.02) before failure when compared with the LP construct.Conclusion:This study demonstrates the biomechanical superiority of medial calcar buttress plating when combined with lateral locked plating as compared with isolated lateral locked plating of OTA/AO type 11-A2.1 proximal humerus in synthetic humeri models.
引用
收藏
页码:E355 / E360
页数:6
相关论文
共 50 条
  • [41] The effect of surgeon-controlled variables on construct stiffness in lateral locked plating of distal femoral fractures
    Weaver, Michael J.
    Chaus, George W.
    Masoudi, Aidin
    Momenzadeh, Kaveh
    Mohamadi, Amin
    Rodriguez, Edward K.
    Vrahas, Mark S.
    Nazarian, Ara
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [42] A biomechanical evaluation of locked plating for distal fibula fractures in an osteoporotic sawbone model
    Bariteau, Jason T.
    Fantry, Amanda
    Blankenhorn, Brad
    Lareau, Craig
    Paller, David
    DiGiovanni, Christopher W.
    FOOT AND ANKLE SURGERY, 2014, 20 (01) : 44 - 47
  • [43] Locked plate fixation and intramedullary nailing for proximal humerus fractures: A biomechanical evaluation
    Hessmann, MH
    Hansen, WSM
    Krummenauer, F
    Pol, TF
    Rommens, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (06): : 1194 - 1201
  • [44] Dorsal Plating, Lateral Plating, and Intramedullary Screw Fixation of Extra-Articular Proximal Phalangeal Fractures: A Cadaveric Biomechanical
    Sivakumar, Brahman
    Graham, David J.
    Clarke, Elizabeth
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (03): : 247 - 252
  • [45] Long-term functional outcomes (median 10 years) after locked plating for displaced fractures of the proximal humerus
    Ockert, Ben
    Siebenbuerger, Georg
    Kettler, Mark
    Braunstein, Volker
    Mutschler, Wolf
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (08) : 1223 - 1231
  • [46] Biomechanical comparison of locked versus non-locked symphyseal plating of unstable pelvic ring injuries
    Godinsky, R. J.
    Vrabec, G. A.
    Guseila, L. M.
    Filipkowski, D. E.
    Elias, J. J.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2018, 44 (02) : 179 - 184
  • [47] Mechanical Assessment of Local Bone Quality to Predict Failure of Locked Plating in a Proximal Humerus Fracture Model
    Roederer, Goetz
    Brianza, Stefano
    Schiuma, Damiano
    Schwyn, Ronald
    Scola, Alexander
    Gueorguiev, Boyko
    Gebhard, Florian
    Tami, Andrea
    ORTHOPEDICS, 2013, 36 (09) : E1134 - E1140
  • [48] Comparison of interfragmentary compression in conventional and locked plating of proximal unicondylar tibia fractures : A biomechanical cadaver study
    Rahm, Stefan
    Ebneter, Lukas
    Schultz, Birte
    Spross, Christian
    Kulling, Fabrice
    Erhardt, Johannes B.
    ACTA ORTHOPAEDICA BELGICA, 2016, 82 (03): : 586 - 592
  • [49] Complications of Locked Plating for Proximal Humeral Fractures in Active Patients in a Level One Trauma Center
    Marsalli, Michael
    de la Paz, Joaquin
    Cordova, Carlos
    Fritis, Diego
    Errazuriz, Juan De Dios
    SHOULDER & ELBOW, 2023, 15 (02) : 181 - 187
  • [50] Biomechanical analysis of helical versus straight plating of proximal third humeral shaft fractures
    Pastor, Torsten
    Zderic, Ivan
    van Knegsel, Kenneth P.
    Beeres, Frank J. P.
    Migliorini, Filippo
    Babst, Reto
    Nebelung, Sven
    Ganse, Bergita
    Schoeneberg, Carsten
    Gueorguiev, Boyko
    Knobe, Matthias
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (08) : 4983 - 4991