Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures

被引:1
作者
Kotler, Joshua A. [1 ,5 ]
Zuppke, Julia N. [2 ]
Abraham, Vivek M. [2 ]
Sanville, Jennifer A. [2 ]
Nabet, Austin C. [2 ]
Carofino, Bradley [3 ]
Gardner, Michael J. [4 ]
Smith, Christopher S. [2 ]
机构
[1] III Marine Expeditionary Force, Marine Logist Grp 3, Med Battal 3, Okinawa, Japan
[2] Naval Med Readiness & Training Ctr, Bone & Joint Sports Med Inst, Portsmouth, VA USA
[3] Atlantic Orthopaed Specialists, Virginia Beach, VA USA
[4] Stanford Univ, Dept Orthopaed Surg, Redwood City, CA USA
[5] III MEF, MLG 3, Med Battal 3, Unit 38404, FPO,AP 96604-8404, Okinawa, Japan
关键词
proximal humerus fracture; internal fixation; biomechanics; locking plates; bending; torsion; medial calcar plating; FIXATION; LOCKING; SUPPORT; EPIDEMIOLOGY; REDUCTION; PARALLEL; FRAGMENT;
D O I
10.1097/BOT.0000000000002619
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective:Medial calcar buttress plating combined with lateral locked plating is biomechanically tested against isolated lateral locked plating in synthetic humeri models for the treatment of proximal humerus fractures.Methods:Proximal humerus fractures (OTA/AO type 11-A2.1) were manufactured in 10 pairs of Sawbones humeri models (Sawbones, Pacific Research Laboratories, Vashon Island, WA). Specimen were randomly assigned and instrumented with either medial calcar buttress plating combined with lateral locked plating (CP) or isolated lateral locked plating (LP). Nondestructive torsional and axial load tests were performed to evaluate construct stiffness. Large-cycle axial tests were conducted followed by destructive ramp-to-failure tests. Cyclic stiffness was compared in both nondestructive and ultimate failure loads. Failure displacement was recorded and compared between groups.Results:The addition of medial calcar buttress plating to lateral locked plating constructs significantly increased the axial (P < 0.01) and torsional (P < 0.01) stiffness of the construct compared with isolated lateral locked plating by 95.56% and 37.46%, respectively. All models demonstrated greater axial stiffness (P < 0.01) after 5000 cycles of axial compression, not dependent on the fixation method. During destructive testing, the CP construct withstood 45.35% larger load (P < 0.01) and congruently exhibited 58% less humeral head displacement (P = 0.02) before failure when compared with the LP construct.Conclusion:This study demonstrates the biomechanical superiority of medial calcar buttress plating when combined with lateral locked plating as compared with isolated lateral locked plating of OTA/AO type 11-A2.1 proximal humerus in synthetic humeri models.
引用
收藏
页码:E355 / E360
页数:6
相关论文
共 50 条
  • [31] Proximal Humerus Fractures in the Elderly Can Be Reliably Fixed With a "Hybrid" Locked-plating Technique
    Barlow, Jonathan D.
    Sanchez-Sotelo, Joaquin
    Torchia, Michael
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (12) : 3281 - 3291
  • [32] Second generation locked plating of proximal humerus fractures-A prospective multicentre observational study
    Roederer, Goetz
    Erhardt, Johannes
    Kuster, Markus
    Vegt, Paul
    Bahrs, Christian
    Kinzl, Lothar
    Gebhard, Florian
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (03) : 425 - 432
  • [33] Does the magnitude of injuries affect the outcome of proximal humerus fractures treated by locked plating (PHILOS)?
    Till Berk
    Sascha Halvachizadeh
    Frederik Bellmann
    Lucas Büsser
    Hans-Christoph Pape
    Florin Allemann
    European Journal of Trauma and Emergency Surgery, 2022, 48 : 4515 - 4522
  • [34] Medial helical versus straight lateral plating of distal femoral fractures-a biomechanical comparative study
    Pastor, Torsten
    Zderic, Ivan
    Souleiman, Firas
    Drenchev, Ludmil
    Skulev, Hristo Kostov
    Berk, Till
    Gueorguiev, Boyko
    Knobe, Matthias
    CLINICAL BIOMECHANICS, 2023, 110
  • [35] Comparison of Locked Plating of Varus Displaced Proximal Humeral Fractures With and Without Fibula Allograft Augmentation
    Davids, Stephen
    Allen, Dexter
    Desarno, Michael
    Endres, Nathan K.
    Bartlett, Craig
    Shafritz, Adam
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (04) : 186 - 192
  • [36] Dual Nonlocked Plating as an Alternative to Locked Plating for Comminuted Distal Fibula Fractures: A Biomechanical Comparison Study
    Randall, Rachel M.
    Nagle, Tara
    Steckler, Andrew
    Billow, Damien
    Berkowitz, Mark J.
    JOURNAL OF FOOT & ANKLE SURGERY, 2019, 58 (05) : 916 - 919
  • [37] Clinical and Radiographic Results of a Retrograde Nail-Washer Combination Versus Lateral Locked Plating for Distal Femur Fractures
    Shaath, M. Kareem
    Kerr, Matthew S.
    Haidukewych, George J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2024, 38 (11) : 584 - 591
  • [38] How to Use Fluoroscopic Imaging to Prevent Intraarticular Screw Perforation During Locked Plating of Proximal Humerus Fractures: A Cadaveric Study
    Lowe, Jason B.
    Monazzam, Shafagh
    Walton, Blaine
    Nelson, Elisha
    Wolinsky, Philip R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (10) : e401 - e407
  • [39] Is retrograde nailing superior to lateral locked plating for complete articular distal femur fractures?
    Vemulapalli, K. Chandra
    Pechero, Guillermo R.
    Warner, Stephen J.
    Achor, Timothy S.
    Gary, Joshua L.
    Munz, John W.
    Choo, Andrew M.
    Prasarn, Mark L.
    Routt, Milton L. Chip, Jr.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (02): : 640 - 644
  • [40] Overdrilling increases the risk of screw perforation in locked plating of complex proximal humeral fractures - A biomechanical cadaveric study
    Burkhard, Benjamin
    Schopper, Clemens
    Ciric, Daniel
    Mischler, Dominic
    Gueorguiev, Boyko
    Varga, Peter
    JOURNAL OF BIOMECHANICS, 2021, 117