Biomechanical Analysis of Combined Medial Calcar and Lateral Locked Plating Versus Isolated Lateral Locked Plating of Proximal Humerus Fractures

被引:1
|
作者
Kotler, Joshua A. [1 ,5 ]
Zuppke, Julia N. [2 ]
Abraham, Vivek M. [2 ]
Sanville, Jennifer A. [2 ]
Nabet, Austin C. [2 ]
Carofino, Bradley [3 ]
Gardner, Michael J. [4 ]
Smith, Christopher S. [2 ]
机构
[1] III Marine Expeditionary Force, Marine Logist Grp 3, Med Battal 3, Okinawa, Japan
[2] Naval Med Readiness & Training Ctr, Bone & Joint Sports Med Inst, Portsmouth, VA USA
[3] Atlantic Orthopaed Specialists, Virginia Beach, VA USA
[4] Stanford Univ, Dept Orthopaed Surg, Redwood City, CA USA
[5] III MEF, MLG 3, Med Battal 3, Unit 38404, FPO,AP 96604-8404, Okinawa, Japan
关键词
proximal humerus fracture; internal fixation; biomechanics; locking plates; bending; torsion; medial calcar plating; FIXATION; LOCKING; SUPPORT; EPIDEMIOLOGY; REDUCTION; PARALLEL; FRAGMENT;
D O I
10.1097/BOT.0000000000002619
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective:Medial calcar buttress plating combined with lateral locked plating is biomechanically tested against isolated lateral locked plating in synthetic humeri models for the treatment of proximal humerus fractures.Methods:Proximal humerus fractures (OTA/AO type 11-A2.1) were manufactured in 10 pairs of Sawbones humeri models (Sawbones, Pacific Research Laboratories, Vashon Island, WA). Specimen were randomly assigned and instrumented with either medial calcar buttress plating combined with lateral locked plating (CP) or isolated lateral locked plating (LP). Nondestructive torsional and axial load tests were performed to evaluate construct stiffness. Large-cycle axial tests were conducted followed by destructive ramp-to-failure tests. Cyclic stiffness was compared in both nondestructive and ultimate failure loads. Failure displacement was recorded and compared between groups.Results:The addition of medial calcar buttress plating to lateral locked plating constructs significantly increased the axial (P < 0.01) and torsional (P < 0.01) stiffness of the construct compared with isolated lateral locked plating by 95.56% and 37.46%, respectively. All models demonstrated greater axial stiffness (P < 0.01) after 5000 cycles of axial compression, not dependent on the fixation method. During destructive testing, the CP construct withstood 45.35% larger load (P < 0.01) and congruently exhibited 58% less humeral head displacement (P = 0.02) before failure when compared with the LP construct.Conclusion:This study demonstrates the biomechanical superiority of medial calcar buttress plating when combined with lateral locked plating as compared with isolated lateral locked plating of OTA/AO type 11-A2.1 proximal humerus in synthetic humeri models.
引用
收藏
页码:E355 / E360
页数:6
相关论文
共 50 条
  • [1] Clinical Results for Minimally Invasive Locked Plating of Proximal Humerus Fractures
    Roederer, Goetz
    Erhardt, Johannes
    Graf, Michael
    Kinzl, Lothar
    Gebhard, Florian
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2010, 24 (07) : 400 - 406
  • [2] Biomechanical analysis of dual versus lateral locked plating in elderly bicondylar tibial plateau fractures: Does medial comminution matter?
    Velez, Dencel A. Garcia
    Headford, Mikel
    Suresh, Krishna Vangipuram
    Liberatos, Paraskevi Marousa
    Bledsoe, Gary
    Revak, Thomas
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (10): : 3109 - 3114
  • [3] Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures
    Katthagen, Jan Christoph
    Schwarze, Michael
    Meyer-Kobbe, Josefin
    Voigt, Christine
    Hurschler, Christof
    Lill, Helmut
    CLINICAL BIOMECHANICS, 2014, 29 (07) : 735 - 741
  • [4] The Biomechanics of Locked Plating for Repairing Proximal Humerus Fractures With or Without Medial Cortical Support
    Lescheid, Jon
    Zdero, Rad
    Shah, Suraj
    Kuzyk, Paul R. T.
    Schemitsch, Emil H.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (05): : 1235 - 1242
  • [5] Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures
    Roederer, Goetz
    Scola, Alexander
    Schmoelz, Werner
    Gebhard, Florian
    Windolf, Markus
    Hofmann-Fliri, Ladina
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (10): : 1327 - 1332
  • [6] Supplementation of Lateral Locked Plating for Distal Femur Fractures: A Biomechanical Study
    Fontenot, Philip B.
    Diaz, Miguel
    Stoops, Kyle
    Barrick, Brett
    Santoni, Brandon
    Mir, Hassan
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (12) : 642 - 648
  • [7] Locked Plating of the Proximal Humerus Using an Endosteal Implant
    Hettrich, Carolyn M.
    Neviaser, Andrew
    Beamer, Brandon S.
    Paul, Omesh
    Helfet, David L.
    Lorich, Dean G.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (04) : 212 - 215
  • [8] Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study
    Warner, Stephen
    Sommer, Christoph
    Zderic, Ivan
    Woodburn, William
    Castle, Richard
    Penman, Jessica
    Saura-Sanchez, Eladio
    Helfet, David L.
    Gueorguiev, Boyko
    Stoffel, Karl
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (05) : 2131 - 2140
  • [9] Locked plating for proximal humeral fractures
    Cheung, Emilie V.
    CURRENT ORTHOPAEDIC PRACTICE, 2008, 19 (05): : 535 - 537
  • [10] Comparative study of single lateral locked plating versus double plating in type C bicondylar tibial plateau fractures
    Neogi, Devdatta Suhas
    Trikha, Vivek
    Mishra, Kaushal Kant
    Bandekar, Shivanand M.
    Yadav, Chandra Shekhar
    INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (02) : 193 - 198