Clinical Comparative Study for Validation of Digital Impression Reliability with the Gypsum Check: A Simple and Fast Way to Evaluate the Trueness and Accuracy of Implant-Supported Rehabilitation

被引:1
作者
Barile, Giuseppe [1 ]
de Rosa, Giovanni [1 ]
Papadia, Paride [2 ]
Muci, Giovannino [2 ]
Capodiferro, Saverio [1 ]
Corsalini, Massimo [1 ]
机构
[1] Univ Bari Aldo Moro, Dept Interdisciplinary Med, I-70100 Bari, Italy
[2] Univ Bari Aldo Moro, Dent Sch, I-70124 Bari, Italy
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 13期
关键词
accuracy; intraoral scan; trueness; digital impression; gypsum check; passive fit; CONVENTIONAL IMPRESSIONS; FIXED PROSTHODONTICS; INTRAORAL SCANNER; PASSIVE FIT; PROSTHESES; FRAMEWORKS; PRECISION;
D O I
10.3390/app13137358
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Despite many advantages, digital impressions, when compared to the conventional one, produce contrasting results and their complete substitution is still under debate. This comparative study aims to test a way to perform a clinical evaluation of digital impression Accuracy and Trueness with a gypsum check. After calculating the Trueness, Precision, and Accuracy of the digital impressions, a gypsum check was fabricated and screwed on implant abutments. The impression was not considered reliable if the gypsum check fractured during the insertion. The gypsum check test was correlated to a cut-off of 100 & mu;m Trueness. Mean Trueness was 151.19 & PLUSMN; 37.23 & mu;m of the first optical impression and 125.47 & PLUSMN; 41.90 & mu;m of the second optical impression. The Precision mean was 39.76 & PLUSMN; 10.89 & mu;m. The mean Accuracy percentage was 98.69 & PLUSMN; 0.29%. The gypsum checks fractured 10 times on 42 tests, and in any case, the Trueness value was above the 100 & mu;m cut off, with a p = 0.001. A gypsum check screwed onto an implant abutment could be considered a way to perform clinical measurement of Trueness, allowing the clinician to understand if the Trueness value is higher or lower than 100 & mu;m and reflecting the reliability of digital impressions.
引用
收藏
页数:15
相关论文
共 44 条
  • [1] Dental Gypsum Verification Jig to Verify Implant Positions: A Clinical Report
    Alhashim, Abdulmohsin
    Flinton, Robert J.
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (04) : 495 - 499
  • [2] A Clinical Comparative Study of 3-Dimensional Accuracy between Digital and Conventional Implant Impression Techniques
    Alsharbaty, Mohammed Hussein M.
    Alikhasi, Marzieh
    Zarrati, Simindokht
    Shamshiri, Ahmed Reza
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (04): : E902 - E908
  • [3] Digital vs. conventional full-arch implant impressions: a comparative study
    Amin, Sarah
    Weber, Hans Peter
    Finkelman, Matthew
    El Rafie, Khaled
    Kudara, Yukio
    Papaspyridakos, Panos
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (11) : 1360 - 1367
  • [4] Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study
    Andriessen, Frank S.
    Riikens, David R.
    van der Meer, Wither J.
    Wismeijer, Daniell W.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03) : 186 - 194
  • [5] [Anonymous], 1994, Accuracy (trueness and precision) of measurement methods and results - Part 1: General principies and defmitions
  • [6] Accuracy evaluation of intraoral optical impressions: A clinical study using a reference appliance
    Atieh, Mohammad A.
    Ritter, Andre V.
    Ko, Ching-Chang
    Duqum, Ibrahim
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (03) : 400 - 405
  • [7] Alginate Materials and Dental Impression Technique: A Current State of the Art and Application to Dental Practice
    Cervino, Gabriele
    Fiorillo, Luca
    Herford, Alan Scott
    Laino, Luigi
    Troiano, Giuseppe
    Amoroso, Giulia
    Crimi, Salvatore
    Matarese, Marco
    D'Amico, Cesare
    Siniscalchi, Enrico Nastro
    Cicciu, Marco
    [J]. MARINE DRUGS, 2019, 17 (01)
  • [8] Chochlidakis KM, 2016, J PROSTHET DENT, V116, P184, DOI 10.1016/j.prosdent.2015.12.017
  • [9] Passive fit of frameworks in titanium and palladium-silver alloy submitted the laser welding
    De Sousa, S. A.
    Nobilo, M. A. De Arruda
    Henriques, G. E. P.
    Mesquita, M. F.
    [J]. JOURNAL OF ORAL REHABILITATION, 2008, 35 (02) : 123 - 127
  • [10] Full arch digital scanning systems performances for implant-supported fixed dental prostheses: a comparative study of 8 intraoral scanners
    Di Fiore, Adolfo
    Meneghello, Roberto
    Graiff, Lorenzo
    Savio, Gianpaolo
    Vigolo, Paolo
    Monaco, Carlo
    Stellini, Edoardo
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2019, 63 (04) : 396 - 403