PLCL-TPU bi-layered artificial blood vessel with compliance matching to host vessel

被引:6
作者
Guan, Lihua [1 ]
Zhao, Huijing [1 ]
Wang, Kai [2 ]
Zhang, Ke-qin [1 ]
Meng, Kai [1 ,3 ]
机构
[1] Soochow Univ, Suzhou, Peoples R China
[2] Nankai Univ, Tianjin, Peoples R China
[3] Soochow Univ, 199 Renai Rd, Ind Pk, Suzhou 215123, Peoples R China
关键词
Artificial blood vessel; compliance; dip-coating; electrospinning; hemodynamics; MECHANICAL-PROPERTIES; VASCULAR GRAFTS; SCAFFOLDS;
D O I
10.1177/08853282231188424
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Compliance mismatch between the artificial blood vessel and the host vessel leads to abnormal hemodynamics and is a major mechanical trigger of intimal hyperplasia. Efforts have been made to achieve higher compliance of artificial blood vessels. However, the preparation of artificial blood vessels with compliance matching to host vessels has not been realized. A bi-layered artificial blood vessel was successfully prepared by dip-coating and electrospinning composite method using poly(L-Lactide-co-caprolactone) (PLCL) and thermoplastic poly(ether urethane) (TPU). In the case of a certain wall thickness (200 & mu;m), thickness ratios of the PLCL inner layer (dip-coating method) and TPU outer layer (electrospinning method) were controlled at 0:1, 1:9, 3:7, 5:5, 7:3, and 1:0 respectively and the compliance, radial tensile properties, burst pressure, and suture retention strength were investigated. Results showed compliance value of the artificial blood vessel decreased with the increase of the thickness ratio, which suggested the compliance of the bi-layered artificial blood vessel can be regulated by adjusting the ratio of the inner and outer layer thicknesses. In the six different artificial blood vessels, the one with thickness ratio of 1:9 not only had high compliance (8.768 & PLUSMN; 0.393%/100 mmHg) but also can guarantee the other mechanical properties, such as the radial breaking strength (6.333 & PLUSMN; 0.689 N/mm), burst pressure (534.473 & PLUSMN; 20.899 mmHg), and suture retention strength (300.773 & PLUSMN; 9.351 cN). The proposed artificial blood vessel preparation method is expected to achieve compliance matching with the host vessel. It is beneficial for eliminating abnormal hemodynamics and reducing intimal hyperplasia.
引用
收藏
页码:194 / 202
页数:9
相关论文
共 27 条
[1]   Poloxamer additive as luminal surface modification to modulate wettability and bioactivities of small-diameter polyurethane/polycaprolactone electrospun hollow tube for vascular prosthesis applications [J].
An Nguyen-My Le ;
Nam Minh-Phuong Tran ;
Thang Bach Phan ;
Tran, Phong A. ;
Lam Dai Tran ;
Thi Hiep Nguyen .
MATERIALS TODAY COMMUNICATIONS, 2021, 26
[2]   Stem cells for tissue engineered vascular bypass grafts [J].
Askari, Forough ;
Solouk, Atefeh ;
Shafieian, Mehdi ;
Seifalian, Alexander M. .
ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2017, 45 (05) :999-1010
[3]   Matching Static and Dynamic Compliance of Small-Diameter Arteries, with Poly(lactide-co-caprolactone) Copolymers: In Vitro and In Vivo Studies [J].
Behr, Jean-Marc ;
Irvine, Scott Alexander ;
Thwin, Chaw-Su ;
Shah, Ankur Harish ;
Bae, Min-Chul Kraun ;
Zussman, Eyal ;
Venkatraman, Subbu .
MACROMOLECULAR BIOSCIENCE, 2020, 20 (03)
[4]   Small-caliber vascular grafts based on a piezoelectric nanocomposite elastomer: Mechanical properties and biocompatibility [J].
Cafarelli, Andrea ;
Losi, Paola ;
Salgarella, Alice Rita ;
Barsotti, Maria Chiara ;
Di Cioccio, Ilaria Bice ;
Foffa, Ilenia ;
Vannozzi, Lorenzo ;
Pingue, Pasqualantonio ;
Soldani, Giorgio ;
Ricotti, Leonardo .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 97 :138-148
[5]  
Cao T., 2022, Medicine in Novel Technology and Devices, V15, P100152, DOI [10.1016/j.medntd.2022.100152, DOI 10.1016/J.MEDNTD.2022.100152]
[6]  
Catto V., 2014, ISRN Vasc. Med, V2014, P923030, DOI [DOI 10.1155/2014/923030, 10.1155/2014/923030]
[7]   Fabrication and characterisation of biomimetic, electrospun gelatin fibre scaffolds for tunica media-equivalent, tissue engineered vascular grafts [J].
Elsayed, Y. ;
Lekakou, C. ;
Labeed, F. ;
Tomlins, P. .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 61 :473-483
[8]   Fabrication of heparinized small diameter TPU/PCL bi-layered artificial blood vessels and in vivo assessment in a rabbit carotid artery replacement model [J].
Fang, Zhiping ;
Xiao, Yonghao ;
Geng, Xue ;
Jia, Liujun ;
Xing, Yuehao ;
Ye, Lin ;
Gu, Yongquan ;
Zhang, Ai-ying ;
Feng, Zeng-guo .
BIOMATERIALS ADVANCES, 2022, 133
[9]   Fabrications of small diameter compliance bypass conduit using electrospinning of clinical grade polyurethane [J].
Faturechi, Rahim ;
Hashemi, Ata ;
Abolfathi, Nabiollah ;
Solouk, Atefeh ;
Seifalian, Alexander .
VASCULAR, 2019, 27 (06) :636-647
[10]   Effect of Wall Structures on Mechanical Properties of Small Caliber PHBHHx Vascular Grafts [J].
Gao, Jing ;
Huang, Zhenzhen ;
Guo, Huiwen ;
Tian, Shunzhu ;
Wang, Lu ;
Li, Yuling .
FIBERS AND POLYMERS, 2019, 20 (11) :2261-2267