Polymethyldopamin@Fe3O4 for Magnetic Solid Phase Extraction of Polycyclic Aromatic Hydrocarbons Combined with DES as Desorption Solvent and High-Performance Liquid Chromatography-Ultraviolet Detection

被引:16
作者
Ghani, Milad [1 ]
Maleki, Behrooz [2 ]
Jafari, Zahra [1 ]
Veisi, Hojat [3 ]
机构
[1] Univ Mazandaran, Fac Chem, Dept Analyt Chem, Babolsar, Iran
[2] Univ Mazandaran, Fac Chem, Dept Organ Chem, Babolsar, Iran
[3] Payame Noor Univ, Dept Chem, Tehran, Iran
关键词
Polycyclic aromatic hydrocarbons; PMDP@Fe3O4; magnetic solid phase extraction; response surface; HPLC-UV; deep eutectic solvent; tap water; river water; smoked fish; smoked rice; DEEP EUTECTIC SOLVENT; SAMPLES PRIOR; MICROEXTRACTION; WATER; ACID;
D O I
10.1080/10406638.2023.2216835
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
Herein, Polymethyldopamin@Fe3O4 (PMDP@Fe3O4) has been synthesized using a very simple, easy, cost-effective, efficient, and fast method. First, magnetic nanoparticles (Fe3O4) were synthesized. It was followed by accommodating polymethyldopamin (PMDP) on the prepared Fe3O4. The prepared PMDP@Fe3O4 was utilized as a sorbent in the Magnetic Solid Phase Extraction (MSPE) of six selected Polycyclic Aromatic Hydrocarbons (PAHs) including anthracene, fluoranthene, fluorene, naphthalene, phenanthrene, and pyrene. The extracted model analytes were desorbed by a Deep Eutectic Solvent (DES) and were analyzed by High-Performance Liquid Chromatography-Ultraviolet detection (HPLC-UV). The method is validated according to ICH guidelines with respect to precision, accuracy, linearity, specificity, robustness, and limits of detection and quantification. Under the optimized condition, the linearity of the method was in the range of 0.1-500 mu g L-1 for the selected analytes. The calibration curves showed a determination of coefficient (r(2)) higher than 0.9986. The limits of detection (LODs) and limits of quantification (LOQs) were calculated to be between 0.03-0.14 and 0.09-0.46 mu g L-1, respectively. The inter-day and intra-day relative standard deviations (RSDs%) were determined to be in the range of 1.7-4.2% in three concentrations. Furthermore, the enrichment factors were found to be 76, 61, 65, 78, 69, and 67 for anthracene, fluoranthene, fluorene, naphthalene, phenanthrene, and pyrene, respectively. Moreover, the calculated absolute recoveries were between 61 and 78%. The results of the real sample analysis and the obtained recoveries indicated that the method was useful and applicable in complicated real samples.
引用
收藏
页码:2381 / 2393
页数:13
相关论文
共 50 条
  • [31] Specific recognition of ribavirin in animal-derived foods by high performance liquid chromatography combined with magnetic solid-phase extraction based on highly selective Zr-Fe3O4
    Qie, Mein
    Zheng, Su
    Bai Xiaoyun
    Bo, Zhang
    Guozhen, Fang
    Shuo, Wang
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (16) : 2602 - 2611
  • [32] Superparamagnetic graphene oxide-based dispersive-solid phase extraction for preconcentration and determination of tamsulosin hydrochloride in human plasma by high performance liquid chromatography-ultraviolet detection
    Pashaei, Yaser
    Ghorbani-Bidkorbeh, Fatemeh
    Shekarchi, Maryam
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1499 : 21 - 29
  • [33] Stir bar sorptive extraction and high-performance liquid chromatography-fluorescence detection for the determination of polycyclic aromatic hydrocarbons in Mate teas
    Zuin, WG
    Montero, L
    Bauer, C
    Popp, P
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1091 (1-2) : 2 - 10
  • [34] Supercritical fluid extraction and high-performance liquid chromatography-fluorescence detection method for polycyclic aromatic hydrocarbons investigation in vegetable oil
    Yusty, MAL
    Daviña, JLC
    FOOD CONTROL, 2005, 16 (01) : 59 - 64
  • [35] Facile and tunable fabrication of Fe3O4/graphene oxide nanocomposites and their application in the magnetic solid-phase extraction of polycyclic aromatic hydrocarbons from environmental water samples
    Han, Qiang
    Wang, Zonghua
    Xia, Jianfei
    Chen, Sha
    Zhang, Xiaoqiong
    Ding, Mingyu
    TALANTA, 2012, 101 : 388 - 395
  • [36] Trace determination of chlorpheniramine in human plasma using magnetic dispersive solid-phase extraction based on a graphene oxide/Fe3O4@polythionine nanocomposite combined with high-performance liquid chromatography
    Daryakenary, Maryam Ahmadi
    Zeeb, Mohsen
    RSC ADVANCES, 2017, 7 (84) : 53210 - 53218
  • [37] Optimization of microwave-assisted solvent extraction of polycyclic aromatic hydrocarbons in marine sediments using a microwave extraction system with high-performance liquid chromatography fluorescence detection and gas chromatography mass spectrometry
    Chee, KK
    Wong, MK
    Lee, HK
    JOURNAL OF CHROMATOGRAPHY A, 1996, 723 (02) : 259 - 271
  • [38] Determination of three hydroxyl polycyclic aromatic hydrocarbons in urine using magnetic solid-phase extraction with magnetic carbon nitride composites coupled with high performance liquid chromatography
    Nian Qixun
    Liu Yuanman
    Sun Bing
    Wang Manman
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2019, 37 (03) : 252 - 258
  • [39] Ultrahigh performance liquid chromatographic analysis and magnetic preconcentration of polycyclic aromatic hydrocarbons by Fe3O4-doped polymeric nanoparticles
    Zhang, Xicui
    Xie, Shunping
    Paau, Man Chin
    Zheng, Baozhan
    Yuan, Hongyan
    Xiao, Dan
    Choi, Martin M. F.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1247 : 1 - 9
  • [40] Development of a vortex-assisted dispersive micro-solid-phase extraction using reduced graphene oxide/Fe3O4 nanocomposites for the determination of chlorfenson pesticide in green tea samples by high-performance liquid chromatography-ultraviolet detection
    Aydin, Nazligul
    Tekin, Zeynep
    Turan, Nouha Bakaraki
    Bakirdere, Sezgin
    CHEMICAL PAPERS, 2023, 77 (04) : 2141 - 2149