Polymethyldopamin@Fe3O4 for Magnetic Solid Phase Extraction of Polycyclic Aromatic Hydrocarbons Combined with DES as Desorption Solvent and High-Performance Liquid Chromatography-Ultraviolet Detection

被引:16
|
作者
Ghani, Milad [1 ]
Maleki, Behrooz [2 ]
Jafari, Zahra [1 ]
Veisi, Hojat [3 ]
机构
[1] Univ Mazandaran, Fac Chem, Dept Analyt Chem, Babolsar, Iran
[2] Univ Mazandaran, Fac Chem, Dept Organ Chem, Babolsar, Iran
[3] Payame Noor Univ, Dept Chem, Tehran, Iran
关键词
Polycyclic aromatic hydrocarbons; PMDP@Fe3O4; magnetic solid phase extraction; response surface; HPLC-UV; deep eutectic solvent; tap water; river water; smoked fish; smoked rice; DEEP EUTECTIC SOLVENT; SAMPLES PRIOR; MICROEXTRACTION; WATER; ACID;
D O I
10.1080/10406638.2023.2216835
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
Herein, Polymethyldopamin@Fe3O4 (PMDP@Fe3O4) has been synthesized using a very simple, easy, cost-effective, efficient, and fast method. First, magnetic nanoparticles (Fe3O4) were synthesized. It was followed by accommodating polymethyldopamin (PMDP) on the prepared Fe3O4. The prepared PMDP@Fe3O4 was utilized as a sorbent in the Magnetic Solid Phase Extraction (MSPE) of six selected Polycyclic Aromatic Hydrocarbons (PAHs) including anthracene, fluoranthene, fluorene, naphthalene, phenanthrene, and pyrene. The extracted model analytes were desorbed by a Deep Eutectic Solvent (DES) and were analyzed by High-Performance Liquid Chromatography-Ultraviolet detection (HPLC-UV). The method is validated according to ICH guidelines with respect to precision, accuracy, linearity, specificity, robustness, and limits of detection and quantification. Under the optimized condition, the linearity of the method was in the range of 0.1-500 mu g L-1 for the selected analytes. The calibration curves showed a determination of coefficient (r(2)) higher than 0.9986. The limits of detection (LODs) and limits of quantification (LOQs) were calculated to be between 0.03-0.14 and 0.09-0.46 mu g L-1, respectively. The inter-day and intra-day relative standard deviations (RSDs%) were determined to be in the range of 1.7-4.2% in three concentrations. Furthermore, the enrichment factors were found to be 76, 61, 65, 78, 69, and 67 for anthracene, fluoranthene, fluorene, naphthalene, phenanthrene, and pyrene, respectively. Moreover, the calculated absolute recoveries were between 61 and 78%. The results of the real sample analysis and the obtained recoveries indicated that the method was useful and applicable in complicated real samples.
引用
收藏
页码:2381 / 2393
页数:13
相关论文
共 50 条
  • [21] Magnetic solid-phase extraction of polycyclic aromatic hydrocarbons using a graphene oxide/Fe3O4@polystyrene nanocomposite
    Amiri, Amirhassan
    Baghayeri, Mehdi
    Sedighi, Mina
    MICROCHIMICA ACTA, 2018, 185 (08)
  • [22] Multiwalled carbon nanotubes as adsorbents of solid-phase extraction for determination of polycyclic aromatic hydrocarbons in environmental waters coupled with high-performance liquid chromatography
    Wang, Wei-Dong
    Huang, Yu-Ming
    Shu, Wei-Qun
    Cao, Ha
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1173 (1-2) : 27 - 36
  • [23] Magnetic nanoparticles—carbon nanotubes hybrid composites for selective solid-phase extraction of polycyclic aromatic hydrocarbons and determination by ultra-high performance liquid chromatography
    Ana I. Corps Ricardo
    Francisco J. Guzmán Bernardo
    Mohammed Zougagh
    Rosa C. Rodríguez Martín-Doimeadios
    Ángel Ríos
    Analytical and Bioanalytical Chemistry, 2017, 409 : 5125 - 5132
  • [24] Application of sunflower stalk-carbon nitride nanosheets as a green sorbent in the solid-phase extraction of polycyclic aromatic hydrocarbons followed by high-performance liquid chromatography
    Khosrowshahi, Elnaz Marzi
    Razmi, Habib
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (09) : 2020 - 2028
  • [25] Fe3O4@ionic liquid@methyl orange nanoparticles as a novel nano-adsorbent for magnetic solid-phase extraction of polycyclic aromatic hydrocarbons in environmental water samples
    Liu, Xiaofei
    Lu, Xin
    Huang, Yong
    Liu, Chengwei
    Zhao, Shulin
    TALANTA, 2014, 119 : 341 - 347
  • [26] Magnetic solid-phase extraction method with modified magnetic ferroferric oxide nanoparticles in a deep eutectic solvent and high-performance liquid chromatography used for the analysis of pharmacologically active ingredients of Epimedium folium
    Zhang, Yanyan
    Li, Zhen
    Li, Li
    Gao, Mingyuan
    Lang, Yixin
    Zhang, Mengyuan
    Likhodii, Sergei
    Hu, Ting
    Zhang, Muxin
    Zhang, Weidong
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1679
  • [27] Graphene oxide/Fe3O4@polythionine nanocomposite as an efficient sorbent for magnetic solid-phase extraction followed by high-performance liquid chromatography for the determination of duloxetine in human plasma
    Zeeb, Mohsen
    Farahani, Hadi
    CHEMICAL PAPERS, 2018, 72 (01): : 15 - 27
  • [28] Ionic liquid-coated Fe3O4 magnetic nanoparticles as an adsorbent of mixed hemimicelles solid-phase extraction for preconcentration of polycyclic aromatic hydrocarbons in environmental samples
    Zhang, Qianli
    Yang, Fei
    Tang, Fei
    Zeng, Kai
    Wu, Kangkang
    Cai, Qingyun
    Yao, Shouzhuo
    ANALYST, 2010, 135 (09) : 2426 - 2433
  • [29] Amino-functionalized Nano Fe3O4 Adsorbent for Magnetic Solid Phase Extraction of Polycyclic Aromatic Hydrocarbons from Environment Water Sample
    Wu, Yue
    Wang, Li
    Wang, Xiao-Nan
    Yan, Xiao-Qing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (07) : 1093 - 1102
  • [30] Application of covalent organic framework as the adsorbent for solid-phase extraction of trace levels of pesticide residues prior to high-performance liquid chromatography-ultraviolet detection
    Song, Yuhong
    Ma, Ruiyang
    Hao, Lin
    Yang, Xiumin
    Wang, Chun
    Wu, Qiuhua
    Wang, Zhi
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1572 : 20 - 26