A ratiometric fluorescent probe for single and two-photon bioimaging of hydrogen peroxide in vitro and in vivo

被引:8
|
作者
Feng, Zhongjiao [1 ,2 ,3 ]
Wu, Jiasheng [1 ,2 ]
Liu, Weimin [1 ,2 ,3 ]
Ren, Haohui [1 ,2 ]
Zheng, Xiuli [1 ,2 ]
Zhang, Wenjun [4 ,5 ]
Lee, Chun-Sing [4 ,5 ]
Wang, Pengfei [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Photochem Convers & Optoelect Mat, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Tech Inst Phys & Chem, CityU CAS Joint Lab Funct Mat & Devices, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, Sch Future Technol, Beijing 100049, Peoples R China
[4] City Univ Hong Kong, Dept Mat Sci & Engn, Hong Kong, Peoples R China
[5] City Univ Hong Kong, Ctr Superdiamond & Adv Films, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
Ratiometric fluorescent probe; Two -photon imaging; Aminoquinoline derivative; Golgi apparatus; Hydrogen peroxide; DISEASE;
D O I
10.1016/j.snb.2023.133668
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogen peroxide (H2O2) as an important reactive oxygen species (ROS) is correlated in various oxidative stress and cell signaling processes. Thus, developing an effective method that can monitor H2O2 in the Golgi apparatus is of great importance. Herein, a Golgi-targeting two-photon fluorescent probe (GT-H2O2) that can be excited by a femto-second pulse (760 nm) is designed. GT-H2O2 utilized aminoquinoline as a fluorophore / Golgi-targetable unit and borate ester as a H2O2-responsive unit with an intramolecular charge transfer strategy. The borate ester of GT-H2O2 was oxidized by H2O2 selectively to afford a new fluorescent molecule GT-NH2, thereby realizing a ratiometric detection of H2O2. The probe exhibited a high sensitivity and selectivity to H2O2 with a linear range from 5 to 60 mu M. In addition, endogenous / exogenous H2O2 could be directly visualized utilizing GT-H2O2 in vitro and in vivo by one/two-photon microscopy.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Excellent benzocoumarin-based ratiometric two-photon fluorescent probe for H2O2 detection
    Hao, Xue-Li
    Guo, Zi-Jing
    Zhang, Chun
    Ren, Ai-Min
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2019, 21 (01) : 281 - 291
  • [42] A ratiometric fluorescent probe for sensing hydrogen peroxide based on a hemicyanine-naphthol fluorophore
    Lei, Yingjie
    Xue, Cong
    Zhang, Sichun
    Sha, Yaowu
    LUMINESCENCE, 2016, 31 (03) : 660 - 664
  • [43] A ratiometric fluorescent probe for monitoring trace hydrogen peroxide in food and living cell mitochondria
    Xin, Haotian
    Cao, Shixian
    Yang, Guiyi
    Huang, Yan
    Zhang, Yan
    Wang, Kang-Nan
    Cao, Duxia
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 418
  • [44] Quinoline-based fluorescent probe for ratiometric detection of hydrogen peroxide in aqueous solution
    Qian, Yuan-Yu
    Xue, Lin
    Hu, De-Xin
    Li, Guo-Ping
    Jiang, Hua
    DYES AND PIGMENTS, 2012, 95 (02) : 373 - 376
  • [45] A novel hepatocyte-targeting ratiometric fluorescent probe for imaging hydrogen peroxide in zebrafish
    Jiang, Wen-Li
    Wang, Wen-Xin
    Liu, Juan
    Li, Yongfei
    Li, Chun-Yan
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 313 (313):
  • [46] Selective Visualization of the Endogenous Peroxynitrite in an Inflamed Mouse Model by a Mitochondria-Targetable Two-Photon Ratiometric Fluorescent Probe
    Cheng, Dan
    Pan, Yue
    Wang, Lu
    Zeng, Zebing
    Yuan, Lin
    Zhang, Xiaobing
    Chang, Young-Tae
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2017, 139 (01) : 285 - 292
  • [47] Rational design of a nitroreductase-activatable two-photon fluorescent probe for hypoxia imaging in cell and in vivo
    Wang, Yue
    Zhang, Li
    Huang, Yan
    Wang, Xiaoyan
    Zhang, Liangwei
    Chen, Lingxin
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 310
  • [48] A turn-on mitochondria-targeted fluorescent probe for detecting and imaging hydrogen peroxide in vitro and in vivo
    Xu, Jia-Qi
    Guo, Jin-Shuang
    Xie, Ke-Feng
    Gao, Meng-Jiao
    Wei, Ran
    Xin, Zhen-Hui
    Kang, Yan-Fei
    DYES AND PIGMENTS, 2022, 204
  • [49] A near-infrared ratiometric/turn-on fluorescent probe for in vivo imaging of hydrogen peroxide in a murine model of acute inflammation
    Hou, Jingli
    Qian, Meng
    Zhao, Huanhuan
    Li, Yingchun
    Liao, Yongfang
    Han, Guifang
    Xu, Zhelong
    Wang, Feng
    Song, Yuguang
    Liu, Yangping
    ANALYTICA CHIMICA ACTA, 2018, 1024 : 169 - 176
  • [50] Simultaneous Monitoring of Tyrosinase and ATP in Thick Brain Tissues Using a Single Two-Photon Fluorescent Probe
    Huang, Hong
    Li, Huiru
    Zhang, Yong
    Xia, Xuhan
    Zhang, Ningwen
    Fan, Haixin
    Guo, Longhua
    Cao, Yongyong
    Pan, Hu
    Deng, Ruijie
    Wang, Yangang
    Ledesma-Amaro, Rodrigo
    Xu, Jianguo
    ADVANCED SCIENCE, 2025,