Effect of iron on biological clogging in porous media: Implications for managed aquifer recharge

被引:1
|
作者
Cui, Ruijuan [1 ,2 ]
Page, Declan [3 ]
Du, Xinqiang [1 ,2 ]
Zhang, Hexuan [1 ,2 ]
Ye, Xueyan [1 ,2 ]
机构
[1] Jilin Univ, Key Lab Groundwater Resources & Environm, Minist Educ, Changchun 130021, Peoples R China
[2] Jilin Univ, Coll New Energy & Environm, Changchun, Peoples R China
[3] CSIRO Environm, Waite Labs, Waite Rd, Urrbrae, Australia
基金
中国国家自然科学基金;
关键词
biological clogging; chemical clogging; managed aquifer recharge (MAR); Pseudomonas aeruginosa; EXTRACELLULAR POLYMERIC SUBSTANCES; ACTIVATED-SLUDGE; ESCHERICHIA-COLI; ARTIFICIAL RECHARGE; BIOFILM; RELEASE; STORAGE; WATER; ADHESION; REMOVAL;
D O I
10.1002/hyp.14839
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Managed aquifer recharge (MAR) is increasingly being adopted to improve water security internationally. However, clogging during MAR remains one of the greatest challenges for sustainable operations. This study examines the effects of iron on biological clogging processes using column experiments and suggests management options. The results indicated that the presence of iron limits the transport of bacteria through the column, and that concentrations <10 mg/L are correlated with increased bacterial growth. Conversely, the increased viscosity of biofilm subsequently limits the transport of iron through the column. Fourier transform infrared spectroscopy and x-ray photoelectron spectroscopy indicated that large iron-Pseudomonas sp. flocs formed which occupied the sand pore spaces. The effect of iron induced chemical clogging was most notable in the initial stage of the experiment while bio-clogging dominated later. There are many recommended values of iron concentration in water recharge, most of them are advised from the point of pollution perspective. Based on these laboratory results, iron concentrations in recharge water for MAR should be <0.3 mg/L to mitigate clogging effects. Furthermore, using non-corrodible materials for bore screen and pumps, and avoiding external oxidant inputs should be considered to prevent iron related chemical and biological clogging.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] The Effect of Toluene-Substrate Concentration on Biological Clogging and Sloughing in Porous Media
    Cheng, W. C.
    Kuo, M. C. Tom
    GROUND WATER MONITORING AND REMEDIATION, 2010, 30 (04) : 73 - 80
  • [22] Microbial community changes induced by Managed Aquifer Recharge activities: linking hydrogeological and biological processes
    Barba, Carme
    Folch, Albert
    Gaju, Nuria
    Sanchez-Vila, Xavier
    Carrasquilla, Marc
    Grau-Martinez, Alba
    Martinez-Alonso, Maira
    HYDROLOGY AND EARTH SYSTEM SCIENCES, 2019, 23 (01) : 139 - 154
  • [23] Improving degradation of emerging organic compounds by applying chaotic advection in Managed Aquifer Recharge in randomly heterogeneous porous media
    Rodriguez-Escales, P.
    Fernandez-Garcia, D.
    Drechsel, J.
    Folch, A.
    Sanchez-Vila, X.
    WATER RESOURCES RESEARCH, 2017, 53 (05) : 4376 - 4392
  • [24] Coupling distributed stormwater collection and managed aquifer recharge: Field application and implications
    Beganskas, S.
    Fisher, A. T.
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2017, 200 : 366 - 379
  • [25] Role of biofilm on virus inactivation in limestone aquifers: implications for managed aquifer recharge
    Esfahani, Amirhosein Ramazanpour
    Batelaan, Okke
    Hutson, John L.
    Fallowfield, Howard J.
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2020, 18 (01) : 21 - 34
  • [26] Role of biofilm on virus inactivation in limestone aquifers: implications for managed aquifer recharge
    Amirhosein Ramazanpour Esfahani
    Okke Batelaan
    John L. Hutson
    Howard J. Fallowfield
    Journal of Environmental Health Science and Engineering, 2020, 18 : 21 - 34
  • [27] Flow Velocity Effects on Fe(III) Clogging during Managed Aquifer Recharge Using Urban Storm Water
    Du, Xinqiang
    Zhang, Hexuan
    Ye, Xueyan
    Lu, Ying
    WATER, 2018, 10 (04)
  • [28] THE EFFECT OF IRON ION ON CLOGGING AND MICROBIAL COMMUNITY STRUCTURE OF GROUNDWATER HEAT PUMP RECHARGE
    Kang, Han
    Li, Dan
    Zang, Chunyue
    Gao, Rongyao
    Wang, Mouwei
    Pan, Jun
    FRESENIUS ENVIRONMENTAL BULLETIN, 2020, 29 (05): : 3656 - 3662
  • [29] Transport of Silica Colloid through Saturated Porous Media under Different Hydrogeochemical and Hydrodynamic Conditions Considering Managed Aquifer Recharge
    Wang, Zhuo
    Zhang, Wenjing
    Li, Shuo
    Zhou, Jingjing
    Liu, Dan
    WATER, 2016, 8 (12):
  • [30] Clogging risk of microplastics particles in porous media during artificial recharge: a laboratory experiment
    Wang, Huan
    Zhang, Junjie
    Chen, Yudao
    Xia, Yuan
    Jian, Peng
    Liang, Haozhi
    FRONTIERS IN MARINE SCIENCE, 2024, 11