Automatic 3D CT liver segmentation based on fast global minimization of probabilistic active contour

被引:2
|
作者
Jin, Renchao [1 ,3 ]
Wang, Manyang [1 ]
Xu, Lijun [2 ]
Lu, Jiayi [1 ]
Song, Enmin [1 ]
Ma, Guangzhi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Comp Sci & Technol, Wuhan, Hubei, Peoples R China
[2] Hubei Univ, Sch Comp & Informat Engn, Wuhan, Peoples R China
[3] Huazhong Univ Sci & Technol, Sch Comp Sci & Technol, Wuhan 430074, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
B-spline surface fitting; liver segmentation; CT; probabilistic active contour; variational method; IMAGE SEGMENTATION; SHAPE MODEL; NETWORK;
D O I
10.1002/mp.16116
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeAutomatic liver segmentation from computed tomography (CT) images is an essential preprocessing step for computer-aided diagnosis of liver diseases. However, due to the large differences in liver shapes, low-contrast to adjacent tissues, and existence of tumors or other abnormalities, liver segmentation has been very challenging. This study presents an accurate and fast liver segmentation method based on a novel probabilistic active contour (PAC) model and its fast global minimization scheme (3D-FGMPAC), which is explainable as compared with deep learning methods. MethodsThe proposed method first constructs a slice-indexed-histogram to localize the volume of interest (VOI) and estimate the probability that a voxel belongs to the liver according its intensity. The probabilistic image would be used to initialize the 3D PAC model. Secondly, a new contour indicator function, which is a component of the model, is produced by combining the gradient-based edge detection and Hessian-matrix-based surface detection. Then, a fast numerical scheme derived for the 3D PAC model is performed to evolve the initial probabilistic image into the global minimizer of the model, which is a smoothed probabilistic image showing a distinctly highlighted liver. Next, a simple region-growing strategy is applied to extract the whole liver mask from the smoothed probabilistic image. Finally, a B-spline surface is constructed to fit the patch of the rib cage to prevent possible leakage into adjacent intercostal tissues. ResultsThe proposed method is evaluated on two public datasets. The average Dice score, volume overlap error, volume difference, symmetric surface distance and volume processing time are 0.96, 7.35%, 0.02%, 1.17 mm and 19.8 s for the Sliver07 dataset, and 0.95, 8.89%, -0.02%$-0.02\%$, 1.45 mm and 23.08 s for the 3Dircadb dataset, respectively. ConclusionsThe proposed fully-automatic approach can effectively segment the liver from low-contrast and complex backgrounds. The quantitative and qualitative results demonstrate that the proposed segmentation method outperforms state-of-the-art traditional automatic liver segmentation algorithms and achieves very competitive performance compared with recent deep leaning-based methods.
引用
收藏
页码:2100 / 2120
页数:21
相关论文
共 50 条
  • [1] Liver Segmentation in CT based on ResUNet with 3D Probabilistic and Geometric Post Process
    Xu, Wendong
    Liu, Hong
    Wang, Xiangdong
    Qian, Yueliang
    2019 IEEE 4TH INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING (ICSIP 2019), 2019, : 685 - 689
  • [2] Automatic 3D model-based method for liver segmentation in MRI based on active contours and total variation minimization
    Bereciartua, Arantza
    Picon, Artzai
    Galdran, Adrian
    Iriondo, Pedro
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 20 : 71 - 77
  • [3] Automatic 3D Segmentation of Renal Cysts in CT
    Badura, Pawel
    Wieclawek, Wojciech
    Pycinski, Bartlomiej
    INFORMATION TECHNOLOGIES IN MEDICINE, ITIB 2016, VOL 1, 2016, 471 : 149 - 163
  • [4] A Generic, Robust and Fully-Automatic Workflow for 3D CT Liver Segmentation
    Gauriau, Romane
    Cuingnet, Remi
    Prevost, Raphael
    Mory, Benoit
    Ardon, Roberto
    Lesage, David
    Bloch, Isabelle
    ABDOMINAL IMAGING: COMPUTATION AND CLINICAL APPLICATIONS, 2013, 8198 : 241 - 250
  • [5] Fast automatic 3D liver segmentation based on a three-level AdaBoost-guided active shape model
    He, Baochun
    Huang, Cheng
    Sharp, Gregory
    Zhou, Shoujun
    Hu, Qingmao
    Fang, Chihua
    Fan, Yingfang
    Jia, Fucang
    MEDICAL PHYSICS, 2016, 43 (05) : 2421 - 2434
  • [6] Automatic Liver Segmentation in CT Volumes with Improved 3D U-net
    Liu, Chunlei
    Cui, Deqi
    Shi, Dejun
    Hu, Zhiqiang
    Qin, Yuan
    Lang, Jinyi
    ISICDM 2018: PROCEEDINGS OF THE 2ND INTERNATIONAL SYMPOSIUM ON IMAGE COMPUTING AND DIGITAL MEDICINE, 2018, : 78 - 82
  • [7] ACTIVE CONTOUR BASED ON 3D STRUCTURE TENSOR APPLIED IN MEDICAL IMAGE SEGMENTATION
    Zhang, Ping
    Cui, Zhaohua
    Xue, Hale
    Zou, Dexuan
    Guo, Li
    INTERNATIONAL JOURNAL OF BIOMATHEMATICS, 2013, 6 (04)
  • [8] Active Contour with Contrast Enhancement for Automatic Liver and Tumor Segmentation
    Priyadarsini, S.
    Selvathi, D.
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (07) : 1553 - 1558
  • [9] Multi-scale attention and deep supervision-based 3D UNet for automatic liver segmentation from CT
    Wang, Jinke
    Zhang, Xiangyang
    Guo, Liang
    Shi, Changfa
    Tamura, Shinichi
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2023, 20 (01) : 1297 - 1316
  • [10] FAST AND FULLY AUTOMATIC 3D ECHOCARDIOGRAPHIC SEGMENTATION USING B-SPLINE EXPLICIT ACTIVE SURFACES
    Barbosa, D.
    Dietenbeck, T.
    Heyde, B.
    Houle, H.
    Friboulet, D.
    D'hooge, J.
    Bernard, O.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1088 - 1091