The myth of aortic valve annulus changes in aortic valve disease

被引:0
|
作者
Peng, Yanren [1 ]
Hu, Huijun [2 ]
Shu, Xiaorong [1 ]
Lin, Yongqing [1 ]
Huang, Weibin [1 ]
Xu, Shuwan [1 ]
Nie, Ruqiong [1 ]
机构
[1] Sun Yat Sen Mem Hosp, Dept Cardiovasc Med, Guangzhou, Peoples R China
[2] Sun Yat Sen Mem Hosp, Dept Radiol, Guangzhou, Guangdong, Peoples R China
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2023年 / 10卷
关键词
aortic regurgitation; aortic stenosis; aortic annulus; computed tomography; transcatheter aortic valve replacement; COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; REPLACEMENT; ECHOCARDIOGRAPHY; ACCURACY; SYSTOLE;
D O I
10.3389/fcvm.2023.1302992
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe characteristics of aortic annulus changes in aortic regurgitation (AR) patients are poorly understood, and predictive factors among aortic valve disease are yet to be established.ObjectiveThis study seeks to elucidate the pattern of annular size fluctuations across different cardiac phases in AR patients and to identify predictors for annular enlargement during either systole or diastole in aortic valve diseases.MethodsA retrospective analysis was conducted on 55 patients with severe aortic valve diseases, including 26 patients with aortic stenosis (AS) and 29 with AR, to discern the two groups' contrasting and analogous patterns of annular changes. The patient sample was expanded to 107 to investigate the factors influencing the size of the annulus during different cardiac phases. Based on our findings, patients were then divided into two groups: those with an annulus that is larger during systole (83 patients) and those where the annulus is larger during diastole (24 patients).ResultsTypically, AR patients exhibit a dynamic annulus, with both perimeter and area being largest during mid-systole. These dimensions diminish progressively and then increase again in early diastole, a pattern consistent with observations in AS patients. Among 107 patients, 21% had diastolic enlargement. Systolic measurements would lead to prosthesis undersizing in 17% of these. Male gender and lower systolic annulus minimum relative to body surface area (AnMin index) were predictors of diastolic enlargement, with ROC curve areas of 0.70 and 0.87 for AR and AS, respectively.ConclusionsSystolic measurements are recommended for AR patients. Gender and the AnMin index are significant predictors, particularly potent in AS patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Successful transcatheter aortic valve replacement in an oversized 800 mm(2) annulus and bicuspid aortic valve
    Buchanan, Kyle D.
    Rogers, Toby
    Shults, Christian
    Ben-Dor, Itsik
    Satler, Lowell F.
    Waksman, Ron
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (08) : S65 - S67
  • [32] Three-Dimensional Measurement of Aortic Annulus Dimensions Using Area or Circumference for Transcatheter Aortic Valve Replacement Valve Sizing: Does It Make a Difference?
    Papachristidis, Alexandros
    Papitsas, Michael
    Roper, Damian
    Wang, Yanzhong
    Dworakowski, Rafal
    Byrne, Jonathan
    Wendler, Olaf
    MacCarthy, Philip
    Monaghan, Mark J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (09) : 871 - 878
  • [33] Anatomical characteristics of aortic valve diseases: Implications for transcatheter aortic valve replacement
    Peng, Yanren
    Shu, Xiaorong
    Lin, Yongqing
    Huang, Weibin
    Xu, Shuwan
    Zheng, Jianming
    Nie, Ruqiong
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2023, 11
  • [34] Elastic Properties of the Descending Aorta in Patients with a Bicuspid or Tricuspid Aortic Valve and Aortic Valvular Disease
    Petrini, Johan
    Jenner, Jonas
    Rickenlund, Anette
    Eriksson, Per
    Franco-Cereceda, Anders
    Caidahl, Kenneth
    Eriksson, Maria J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2014, 27 (04) : 393 - 404
  • [35] Comparison of patients with bicuspid and tricuspid aortic valve in transcatheter aortic valve implantation
    Zhu, Zhongkai
    Xiong, Tianyuan
    Chen, Mao
    EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (03) : 209 - 220
  • [36] Valve Sizing for Pure Aortic Regurgitation During Transcatheter Aortic Valve Replacement Deformation Dynamic of the Aortic Annulus in Different Valve Pathology May Be Different
    Zhu, Da
    Chen, Wei
    Peng, Liqing
    Guo, Yingqiang
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (02) : 372 - 373
  • [37] Successful Management of Annulus Rupture in Transcatheter Aortic Valve Implantation
    Hayashida, Kentaro
    Bouvier, Erik
    Lefevre, Thierry
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (01) : 90 - 91
  • [38] The Functional Aortic Annulus in the 3D Era: Focus on Transcatheter Aortic Valve Replacement for the Perioperative Echocardiographer
    Patel, Prakash A.
    Gutsche, Jacob T.
    Vernick, William J.
    Giri, Jay S.
    Ghadimi, Kamrouz
    Weiss, Stuart J.
    Jagasia, Dinesh H.
    Bavaria, Joseph E.
    Augoustides, John G. T.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (01) : 240 - 245
  • [39] Echocardiography in Transcatheter Aortic Valve Replacement
    Vollema, E. Mara
    Delgado, Victoria
    Bax, Jeroen J.
    HEART LUNG AND CIRCULATION, 2019, 28 (09) : 1384 - 1399
  • [40] Reduction Aortoplasty for the Ascending Aortic Aneurysm With Aortic Valve Disease Does Bicuspid Valve Matter?
    Hwang, Ho Young
    Shim, Mi-Suk
    Park, Eun-Ah
    Ahn, Hyuk
    CIRCULATION JOURNAL, 2011, 75 (02) : 322 - 328