The myth of aortic valve annulus changes in aortic valve disease

被引:0
|
作者
Peng, Yanren [1 ]
Hu, Huijun [2 ]
Shu, Xiaorong [1 ]
Lin, Yongqing [1 ]
Huang, Weibin [1 ]
Xu, Shuwan [1 ]
Nie, Ruqiong [1 ]
机构
[1] Sun Yat Sen Mem Hosp, Dept Cardiovasc Med, Guangzhou, Peoples R China
[2] Sun Yat Sen Mem Hosp, Dept Radiol, Guangzhou, Guangdong, Peoples R China
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2023年 / 10卷
关键词
aortic regurgitation; aortic stenosis; aortic annulus; computed tomography; transcatheter aortic valve replacement; COMPUTED-TOMOGRAPHY; MAGNETIC-RESONANCE; REPLACEMENT; ECHOCARDIOGRAPHY; ACCURACY; SYSTOLE;
D O I
10.3389/fcvm.2023.1302992
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe characteristics of aortic annulus changes in aortic regurgitation (AR) patients are poorly understood, and predictive factors among aortic valve disease are yet to be established.ObjectiveThis study seeks to elucidate the pattern of annular size fluctuations across different cardiac phases in AR patients and to identify predictors for annular enlargement during either systole or diastole in aortic valve diseases.MethodsA retrospective analysis was conducted on 55 patients with severe aortic valve diseases, including 26 patients with aortic stenosis (AS) and 29 with AR, to discern the two groups' contrasting and analogous patterns of annular changes. The patient sample was expanded to 107 to investigate the factors influencing the size of the annulus during different cardiac phases. Based on our findings, patients were then divided into two groups: those with an annulus that is larger during systole (83 patients) and those where the annulus is larger during diastole (24 patients).ResultsTypically, AR patients exhibit a dynamic annulus, with both perimeter and area being largest during mid-systole. These dimensions diminish progressively and then increase again in early diastole, a pattern consistent with observations in AS patients. Among 107 patients, 21% had diastolic enlargement. Systolic measurements would lead to prosthesis undersizing in 17% of these. Male gender and lower systolic annulus minimum relative to body surface area (AnMin index) were predictors of diastolic enlargement, with ROC curve areas of 0.70 and 0.87 for AR and AS, respectively.ConclusionsSystolic measurements are recommended for AR patients. Gender and the AnMin index are significant predictors, particularly potent in AS patients.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Comparison of Aortic Annulus Dimension After Aortic Valve Neocuspidization With Valve Replacement and Normal Valve
    Yamamoto, Yoshitaka
    Iino, Kenji
    Shintani, Yoshiko
    Kato, Hiroki
    Kimura, Keiichi
    Watanabe, Go
    Takemura, Hirofumi
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2017, 29 (02) : 143 - 149
  • [22] Nature of aortic annulus: Influence of annulus dynamic on the aortic valve hemodynamics
    Hashemifard, Alireza
    Fatouraee, Nasser
    Nabaei, Malikeh
    Computers in Biology and Medicine, 2024, 181
  • [23] Potential Mechanism of Annulus Rupture During Transcatheter Aortic Valve Implantation
    Hayashida, Kentaro
    Bouvier, Erik
    Lefevre, Thierry
    Hovasse, Thomas
    Morice, Marie-Claude
    Chevalier, Bernard
    Romano, Mauro
    Garot, Philippe
    Farge, Arnaud
    Donzeau-Gouge, Patrick
    Cormier, Bertrand
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (05) : E742 - E746
  • [24] Impact of Valve Size on Paravalvular Leak and Valve Hemodynamics in Patients With Borderline Size Aortic Valve Annulus
    Talmor-Barkan, Yeela
    Kornowski, Ran
    Bar, Noam
    Ben-Shoshan, Jeremy
    Vaknin-Assa, Hanna
    Hamdan, Ashraf
    Kruchin, Boris
    Barbash, Israel M.
    Danenberg, Haim
    Perlman, Gidon Y.
    Konigstein, Maayan
    Finkelstein, Ariel
    Steinvil, Arie
    Merdler, Ilan
    Segev, Amit
    Barsheshet, Alon
    Codner, Pablo
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [25] Characteristics of aortic valve dysfunction and ascending aorta dimensions according to bicuspid aortic valve morphology
    Shin, Hong Ju
    Shin, Je Kyoun
    Chee, Hyun Kun
    Kim, Jun Suk
    Ko, Sung Min
    EUROPEAN RADIOLOGY, 2015, 25 (07) : 2103 - 2114
  • [26] Surgical aortic valve replacement in small aortic annulus
    Vaidya, Yash P.
    Cavanaugh, Shaelyn M.
    Sandhu, Aqeel A.
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (07) : 2502 - 2509
  • [27] Aortic valve and aortic root features in CT angiography in patients considered for aortic valve repair
    Regeer, Madelien V.
    Kamperidis, Vasileios
    Versteegh, Michel I. M.
    Klautz, Robert J. M.
    Scholte, Arthur J. H. A.
    Bax, Jeroen J.
    Schalij, Martin J.
    Marsan, Nina Ajmone
    Delgado, Victoria
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (04) : 299 - 306
  • [28] 3D Characterization of the Aortic Valve and Aortic Arch in Bicuspid Aortic Valve Patients
    Yeats, Breandan B.
    Galvez, Dahlia
    Sivakumar, Sri Krishna
    Holst, Kimberly
    Polsani, Venkateshwar
    Yadav, Pradeep K.
    Thourani, Vinod H.
    Yoganathan, Ajit
    Dasi, Lakshmi P.
    ANNALS OF BIOMEDICAL ENGINEERING, 2024, 52 (08) : 2258 - 2268
  • [29] Anatomical and clinical predictors of valve dysfunction and aortic dilation in bicuspid aortic valve disease
    Evangelista, Arturo
    Gallego, Pastora
    Calvo-Iglesias, Francisco
    Bermejo, Javier
    Robledo-Carmona, Juan
    Sanchez, Violeta
    Saura, Daniel
    Arnold, Roman
    Carro, Amelia
    Maldonado, Giuliana
    Sao-Aviles, Augusto
    Teixido, Gisela
    Galian, Laura
    Rodriguez-Palomares, Jose
    Garcia-Dorado, David
    HEART, 2018, 104 (07) : 566 - 573
  • [30] Two-dimensional transesophageal echocardiography assessment of the major aortic annulus diameter in patients undergoing transcatheter aortic valve replacement
    Librera, Mariateresa
    Carlomagno, Guido
    Paolillo, Stefania
    Romano, Maurizio
    Antonini-Canterin, Francesco
    D'Alto, Michele
    De Martino, Giuseppe
    Briguori, Carlo
    JOURNAL OF CARDIOVASCULAR ECHOGRAPHY, 2021, 31 (01) : 23 - 28