Line-Field Confocal Optical Coherence Tomography for the Diagnosis of Skin Carcinomas: Real-Life Data over Three Years

被引:11
|
作者
Donelli, Carolina [1 ]
Suppa, Mariano [2 ,3 ]
Tognetti, Linda [1 ]
Perrot, Jean Luc [2 ,4 ]
Calabrese, Laura [1 ]
Perez-Anker, Javiera [5 ,6 ]
Malvehy, Josep [5 ,6 ]
Rubegni, Pietro [1 ]
Cinotti, Elisa [1 ,2 ]
机构
[1] Univ Siena, Dermatol Sect, Dept Med Surg & Neurol Sci, I-53100 Siena, Italy
[2] Soc Francaise Dermatol SFD, Grp Imagerie Cutanee Non Invas GICNI, F-75008 Paris, France
[3] Univ Libre Bruxelles, Hop Erasme, Dept Dermatol, B-1050 Brussels, Belgium
[4] Univ Hosp St Etienne, Dept Dermatol, F-42270 St Etienne, France
[5] Univ Barcelona, Hosp Clin Barcelona, Dermatol Dept, Melanoma Unit,IDIBAPS, Barcelona 08001, Spain
[6] Inst Salud Carlos III, CIBER Enfermedades Raras, Barcelona 08007, Spain
关键词
LC-OCT; optical coherence tomography; basal cell carcinoma; squamous cell carcinoma; non-melanoma skin cancer; sensitivity; specificity; accuracy; imaging;
D O I
10.3390/curroncol30100639
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Line-field confocal optical coherence tomography (LC-OCT) can help the clinical diagnosis of skin diseases. The present study aimed to evaluate the sensitivity, specificity, and diagnostic accuracy of LC-OCT for the diagnosis of the most frequent non-melanoma skin cancers (NMSCs), i.e., basal cell carcinoma (BCC) and squamous cell carcinoma (SCC). Comparing LC-OCT diagnostic performances with those of dermoscopy, histopathological examination was used as a gold standard. For every study endpoint, the diagnostic ability of LC-OCT revealed superiority over the dermoscopic examination. In particular, a significant increase in specificity was observed. Sensitivity, specificity, and diagnostic accuracy of dermoscopy and LC-OCT for the diagnosis of malignancy were, respectively, 0.97 (CI 0.94-0.99), 0.43 (CI 0.36-0.51), and 0.77 (CI 0.72-0.81) for dermoscopy and 0.99 (CI 0.97-1.00), 0.90 (CI 0.84-0.94), and 0.96 (CI 0.93-0.97) for LC-OCT. The positive predictive value (PPV) resulted in 0.74 (CI 0.69-0.78) for dermoscopy and 0.94 (CI 0.91-0.97) for LC-OCT, and the negative predictive value (NPV) was 0.89 (CI 0.81-0.95) for dermoscopy and 0.98 (CI 0.95-1.00) for LC-OCT. Finally, our real-life study showed a potentially important role of LC-OCT in the non-invasive diagnosis of NMSCs, especially BCC. The real-time imaging technique could spare unnecessary biopsies with an increased sensitivity, a much higher specificity, and better accuracy than clinical assessment with dermoscopy alone.
引用
收藏
页码:8853 / 8864
页数:12
相关论文
共 50 条
  • [1] Diagnostic Accuracy of Line-Field Confocal Optical Coherence Tomography for the Diagnosis of Skin Carcinomas
    Cinotti, Elisa
    Brunetti, Tullio
    Cartocci, Alessandra
    Tognetti, Linda
    Suppa, Mariano
    Malvehy, Josep
    Perez-Anker, Javiera
    Puig, Susanna
    Perrot, Jean Luc
    Rubegni, Pietro
    DIAGNOSTICS, 2023, 13 (03)
  • [2] Skin lesion imaging with line-field confocal optical coherence tomography
    Cazalas, Maxime
    Levecq, Olivier
    Azimani, Hicham
    Siret, David
    Barut, Anais
    Suppa, Mariano
    del Marmol, Veronique
    Malvehy, Josep
    Cinotti, Elisa
    Rubegni, Pietro
    Perrot, Jean-Luc
    Dubois, Arnaud
    PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY 2019, 2019, 10851
  • [3] Handheld line-field confocal optical coherence tomography for dermatology
    Ogien, Jonas
    Levecq, Olivier
    Cazalas, Maxime
    Suppa, Mariano
    del Marmol, Veronique
    Malvehy, Josep
    Cinotti, Elisa
    Rubegni, Pietro
    Perrot, Jean-Luc
    Dubois, Arnaud
    PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY 2020, 2020, 11211
  • [4] Line-field confocal optical coherence tomography
    Ogien, Jonas
    Levecq, Olivier
    Azimani, Hicham
    Davis, Arthur
    Xue, Weikai
    Siret, David
    Perrot, Jean-Luc
    Dubois, Arnaud
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXIII, 2019, 10867
  • [5] Line-Field Confocal Optical Coherence Tomography Evaluation of Eyelid Skin Lesions
    Di Stefani, Alessandro
    Cappilli, Simone
    Cuffaro, Giovanni
    Fionda, Bruno
    Pagliara, Monica Maria
    Paradisi, Andrea
    Ricci, Costantino
    Rossi, Ernesto
    Sammarco, Maria Grazia
    Schinzari, Giovanni
    Tagliaferri, Luca
    Blasi, Maria Antonietta
    Cinotti, Elisa
    Moro, Alessandro
    Savino, Gustavo
    Suppa, Mariano
    Peris, Ketty
    DIAGNOSTICS, 2023, 13 (23)
  • [6] Line-Field Confocal Optical Coherence Tomography for the Diagnosis of Skin Tumors: A Systematic Review and Meta-Analysis
    Razi, Shazli
    Kuo, Yen-Hong
    Pathak, Gaurav
    Agarwal, Priya
    Horgan, Arianna
    Parikh, Prachi
    Deshmukh, Farah
    Rao, Babar K.
    DIAGNOSTICS, 2024, 14 (14)
  • [7] Optical skin biopsy using multimodal line-field confocal optical coherence tomography (LC-OCT)
    Ogien, Jonas
    Waszczuk, Lena
    Suppa, Mariano
    del Marmol, Veronique
    Malvehy, Josep
    Cinotti, Elisa
    Rubegni, Pietro
    Perrot, Jean-Luc
    Dubois, Arnaud
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXVI, 2022, 11948
  • [8] Interobserver agreement on line-field confocal optical coherence tomography image markers in keratinocyte carcinomas and precursor lesions
    Jacobsen, Kevin
    Ortner, Vinzent Kevin
    Wenande, Emily
    Fredman, Gabriella
    Untracht, Gavrielle R.
    Wolswijk, Tom
    Cruts, Emmy
    Mosterd, Klara
    Nielsen, Kari
    Philipsen, Peter Alshede
    Wiegell, Stine Regin
    Haedersdal, Merete
    ARCHIVES OF DERMATOLOGICAL RESEARCH, 2024, 316 (08)
  • [9] Line-field confocal optical coherence tomography: technology and application in dermatology
    Ogien, Jonas
    Levecq, Olivier
    Azimani, Hicham
    Siret, David
    Perrot, Jean-Luc
    Dubois, Arnaud
    BIOMEDICAL SPECTROSCOPY, MICROSCOPY, AND IMAGING, 2020, 11359
  • [10] Line-field confocal optical coherence tomography for high-resolution noninvasive imaging of skin tumors
    Dubois, Arnaud
    Levecq, Olivier
    Azimani, Hicham
    Siret, David
    Barut, Anais
    Suppa, Mariano
    del Marmol, Veronique
    Malvehy, Josep
    Cinotti, Elisa
    Rubegni, Pietro
    Perrot, Jean-Luc
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (10)