Optimal Dosage of Indocyanine Green Fluorescence for Intraoperative Positive Staining in Laparoscopic Anatomical Liver Resection

被引:5
|
作者
Kasai, Meidai [1 ]
Aihara, Tsukasa [1 ]
Ikuta, Shinichi [1 ]
Nakajima, Takayoshi [2 ]
Yamanaka, Naoki [1 ]
机构
[1] Meiwa Hosp, Dept Surg, Nishinomiya, Hyogo, Japan
[2] Meiwa Hosp, Dept Surg, Nishinomiya, Japan
关键词
roc curve analysis; positive staining; indocyanine green; fluorescence imaging technology; laparoscopic anatomical liver resection; NAVIGATION;
D O I
10.7759/cureus.46771
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionFluorescence imaging technology, specifically utilizing indocyanine green (ICG), has emerged as a valuable tool in laparoscopic hepatectomy. In particular, laparoscopic anatomical liver resection (ALR) has benefited from the implementation of both positive and negative staining methods. A case series study reported a success rate of 53% for the positive staining method, citing potential issues regarding the proper ICG dosage needed for accurate fluorescence. Thus, it is crucial to conduct research to investigate the optimal dosage for ICG-positive staining in clinical practice to maximize the benefits of this technique.Materials and methodsThis retrospective study was conducted at a single center, Meiwa Hospital, and received approval from the hospital's ethics committee in accordance with the Helsinki Declaration. We reviewed the records of 264 patients who underwent open and laparoscopic hepatectomies for benign and malignant liver diseases from January 2019 to January 2023. Of these, 18 patients who underwent laparoscopic ALR with the ICG-positive staining method were evaluated. Fluorescence-emitting segmental borders were assessed immediately after puncture (first stage) and during parenchymal dissection (second stage). In the first stage, we evaluated the intensity of fluorescence emission, categorizing it as "strong" or "weak." The absence of visible fluorescence emission was considered a puncture failure. During the second stage of evaluation, from parenchymal resection to completion, we assessed the sustainability of fluorescence emission, defining it as "clear" or "contaminated." Both evaluations were subjectively judged by three surgeons at our center. The ICG quantity per targeted portal vein-bearing liver volume (mg/100 mL) was calculated for each patient, and the optimal dosage was determined using receiver operating characteristic (ROC) curve analysis. To ascertain the minimum value for adequate fluorescence emission intensity, ROC curve analysis was performed to discriminate between binary outcomes of "strong" or "weak" emission. Furthermore, to establish the maximum value for maintaining a clear fluorescence border, ROC curve analysis was conducted to discriminate between "clear" and "contaminated" during the second evaluation.ResultsAmong the 18 successful puncture cases, the first-stage evaluation of fluorescence intensity revealed 14 punctures with "strong" intensity and four punctures with "weak" intensity. In the second-stage evaluation, 13 cases demonstrated "clear" borders, while five cases exhibited "contaminated" borders. ROC curve analysis was performed to determine the optimal ICG dose for adequate fluorescence intensity and preservation of clear borders during dissection. The analysis indicated that the appropriate ICG dose for achieving optimal intensity was 0.028 mg/100 mL (area under the curve [AUC]: 0.893), while the dose that prevented contamination of fluorescence in non-target areas until after dissection was 0.083 mg/100 mL (AUC: 0.723).ConclusionsLaparoscopic anatomical resection using the positive staining method requires an optimal ICG dosage of 0.028-0.083 mg per 100 mL of liver volume. By employing this methodology, more precise and safer laparoscopic anatomical resections can be conducted, thereby enhancing the safety of the surgical procedure for patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Intraoperative brain tumor resection with indocyanine green using augmented microscopy
    Watson, Jeffrey R.
    Martirosyan, Nikolay
    Lemole, G. Michael, Jr.
    Trouard, Theodore P.
    Romanowski, Marek
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (09)
  • [42] The impact of indocyanine-green fluorescence angiogram on colorectal resection
    Chang, Yuk Kwan
    Foo, Chi Chung
    Yip, Jeremy
    Wei, Rockson
    Ng, Ka Kin
    Lo, Oswens
    Choi, Hok Kwok
    Law, Wai Lun
    SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2019, 17 (05): : 270 - 276
  • [43] Utility of indocyanine green fluorescence during laparoscopic cholecystectomy (with video)
    Wu, Haojun
    Liang, Mengping
    Chen, Liping
    JOURNAL OF VISCERAL SURGERY, 2022, 159 (04) : 339 - 340
  • [44] Surgical margin status outcome of intraoperative indocyanine green fluorescence-guided laparoscopic hepatectomy in liver malignancy: a systematic review and meta-analysis
    Tangsirapat, Vorapatu
    Kengsakul, Malika
    Udomkarnjananun, Suwasin
    Sookpotarom, Paiboon
    Rattanasakalwong, Mati
    Nuchanatanon, Jantaluck
    Kongon, Panutchaya
    Wongta, Kitti
    BMC SURGERY, 2024, 24 (01)
  • [45] Intraoperative guidance using ICG fluorescence imaging system for safe and precise laparoscopic liver resection
    Otsuka, Yuichiro
    Matsumoto, Yu
    Ito, Yuko
    Okada, Rei
    Maeda, Tetsuya
    Ishii, Jun
    Kajiwara, Yoji
    Okubo, Kazunori
    Funahashi, Kimihiko
    Kaneko, Hironori
    MINERVA SURGERY, 2021, 76 (03): : 211 - 219
  • [46] Intraoperative Indocyanine Green Fluorescence to Assure Vital Parathyroids in Thyroid Resections
    Karampinis, Ioannis
    Di Meo, Giovanna
    Gerken, Andreas
    Stasiunaitis, Vytautas
    Lammert, Alexander
    Nowak, Kai
    ZENTRALBLATT FUR CHIRURGIE, 2018, 143 (04): : 380 - 384
  • [47] Indocyanine green fluorescence angiography during laparoscopic low anterior resection: results of a case-matched study
    Luigi Boni
    Abe Fingerhut
    Alessandro Marzorati
    Stefano Rausei
    Gianlorenzo Dionigi
    Elisa Cassinotti
    Surgical Endoscopy, 2017, 31 : 1836 - 1840
  • [48] Indocyanine green fluorescence angiography during laparoscopic low anterior resection: results of a case-matched study
    Boni, Luigi
    Fingerhut, Abe
    Marzorati, Alessandro
    Rausei, Stefano
    Dionigi, Gianlorenzo
    Cassinotti, Elisa
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (04): : 1836 - 1840
  • [49] Infrared intraoperative fluorescence imaging using indocyanine green in thoracic surgery
    Okusanya, Olugbenga T.
    Hess, Nicholas R.
    Luketich, James D.
    Sarkaria, Inderpal S.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (03) : 512 - 518
  • [50] Evaluation of Intranasal Flap Perfusion by Intraoperative Indocyanine Green Fluorescence Angiography
    Schneider, John
    Chandler, William F.
    OPERATIVE NEUROSURGERY, 2018, 15 (06) : 676 - 676