Optimal Dosage of Indocyanine Green Fluorescence for Intraoperative Positive Staining in Laparoscopic Anatomical Liver Resection

被引:5
|
作者
Kasai, Meidai [1 ]
Aihara, Tsukasa [1 ]
Ikuta, Shinichi [1 ]
Nakajima, Takayoshi [2 ]
Yamanaka, Naoki [1 ]
机构
[1] Meiwa Hosp, Dept Surg, Nishinomiya, Hyogo, Japan
[2] Meiwa Hosp, Dept Surg, Nishinomiya, Japan
关键词
roc curve analysis; positive staining; indocyanine green; fluorescence imaging technology; laparoscopic anatomical liver resection; NAVIGATION;
D O I
10.7759/cureus.46771
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionFluorescence imaging technology, specifically utilizing indocyanine green (ICG), has emerged as a valuable tool in laparoscopic hepatectomy. In particular, laparoscopic anatomical liver resection (ALR) has benefited from the implementation of both positive and negative staining methods. A case series study reported a success rate of 53% for the positive staining method, citing potential issues regarding the proper ICG dosage needed for accurate fluorescence. Thus, it is crucial to conduct research to investigate the optimal dosage for ICG-positive staining in clinical practice to maximize the benefits of this technique.Materials and methodsThis retrospective study was conducted at a single center, Meiwa Hospital, and received approval from the hospital's ethics committee in accordance with the Helsinki Declaration. We reviewed the records of 264 patients who underwent open and laparoscopic hepatectomies for benign and malignant liver diseases from January 2019 to January 2023. Of these, 18 patients who underwent laparoscopic ALR with the ICG-positive staining method were evaluated. Fluorescence-emitting segmental borders were assessed immediately after puncture (first stage) and during parenchymal dissection (second stage). In the first stage, we evaluated the intensity of fluorescence emission, categorizing it as "strong" or "weak." The absence of visible fluorescence emission was considered a puncture failure. During the second stage of evaluation, from parenchymal resection to completion, we assessed the sustainability of fluorescence emission, defining it as "clear" or "contaminated." Both evaluations were subjectively judged by three surgeons at our center. The ICG quantity per targeted portal vein-bearing liver volume (mg/100 mL) was calculated for each patient, and the optimal dosage was determined using receiver operating characteristic (ROC) curve analysis. To ascertain the minimum value for adequate fluorescence emission intensity, ROC curve analysis was performed to discriminate between binary outcomes of "strong" or "weak" emission. Furthermore, to establish the maximum value for maintaining a clear fluorescence border, ROC curve analysis was conducted to discriminate between "clear" and "contaminated" during the second evaluation.ResultsAmong the 18 successful puncture cases, the first-stage evaluation of fluorescence intensity revealed 14 punctures with "strong" intensity and four punctures with "weak" intensity. In the second-stage evaluation, 13 cases demonstrated "clear" borders, while five cases exhibited "contaminated" borders. ROC curve analysis was performed to determine the optimal ICG dose for adequate fluorescence intensity and preservation of clear borders during dissection. The analysis indicated that the appropriate ICG dose for achieving optimal intensity was 0.028 mg/100 mL (area under the curve [AUC]: 0.893), while the dose that prevented contamination of fluorescence in non-target areas until after dissection was 0.083 mg/100 mL (AUC: 0.723).ConclusionsLaparoscopic anatomical resection using the positive staining method requires an optimal ICG dosage of 0.028-0.083 mg per 100 mL of liver volume. By employing this methodology, more precise and safer laparoscopic anatomical resections can be conducted, thereby enhancing the safety of the surgical procedure for patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Ultrasound-Guided Preoperative Positive Percutaneous Indocyanine Green Fluorescence Staining for Laparoscopic Anatomical Liver Resection
    Aoki, Takeshi
    Koizumi, Tomotake
    Mansour, Doaa A.
    Fujimori, Akira
    Kusano, Tomokazu
    Matsuda, Kazuhiro
    Tashiro, Yoshihiko
    Watanabe, Makoto
    Otsuka, Koji
    Murakami, Masahiko
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2020, 230 (03) : E7 - E12
  • [2] Comparing the accuracy of positive and negative indocyanine green staining in guiding laparoscopic anatomical liver resection: protocol for a randomised controlled trial
    Alomari, Malek Abdallah Muflih
    Wakabayashi, Taiga
    Colella, Marco
    Mishima, Kouhei
    Fujiyama, Yoshiki
    Ababneh, Ebaa
    Wakabayashi, Go
    BMJ OPEN, 2023, 13 (09):
  • [3] Laparoscopic anatomical liver resection using indocyanine green fluorescence imaging
    Urade, Takeshi
    Sawa, Hidehiro
    Iwatani, Yoshiteru
    Abe, Tomoki
    Fujinaka, Ryosuke
    Murata, Koichi
    Mii, Yasuhiko
    Man-i, Mariko
    Oka, Shigeteru
    Kuroda, Daisuke
    ASIAN JOURNAL OF SURGERY, 2020, 43 (01) : 362 - 368
  • [4] A novel method of ultrasound-guided positive staining using indocyanine green fluorescence in laparoscopic anatomical liver resection of segments VII and VIII
    Jiang, Zedong
    Zhou, Bo
    Zheng, Xiang
    Li, Guogang
    Gao, Zhenzhen
    Tian, Yang
    Shao, Chunlong
    Xu, Shaoyan
    Yan, Sheng
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [5] Optimal Indocyanine Green Dosage for Repetitive Angiography for Laparoscopic Colorectal Surgery
    Son, Gyung Mo
    Park, Sang-Ho
    Kim, Nam Su
    Yun, Mi Sook
    Lee, In Young
    Kwon, Myeong-Sook
    Kim, Tae Kyun
    Lee, Eun Hwa
    Hwang, Eun Jung
    Baek, Kwang-Ryul
    MEDICINA-LITHUANIA, 2024, 60 (12):
  • [6] Indocyanine green staining for intraoperative perfusion assessment
    Salehi, Omid
    Kazakova, Vera
    Vega, Eduardo A.
    Conrad, Claudius
    MINERVA SURGERY, 2021, 76 (03): : 220 - 228
  • [7] Usefulness of indocyanine green fluorescence in laparoscopic resection of choledochal cyst in children
    Garcia-Hernandez, Carlos
    Cabrera-Gonzalez, Hugo
    Carvajal-Figueroa, Lourdes
    Archivaldo-Garcia, Christian
    Valero-Mamani, Romer Jesus
    Martinez-Flores, Ramiro Adebel
    JOURNAL OF PEDIATRIC SURGERY CASE REPORTS, 2022, 76
  • [8] Intraoperative Use of Indocyanine Green Fluorescence Videography for Resection of a Spinal Cord Hemangioblastoma
    Hwang, Steven W.
    Malek, Adel M.
    Schapiro, Robert
    Wu, Julian K.
    NEUROSURGERY, 2010, 67 (03) : 300 - 302
  • [9] Robo-Lap Approach for Anatomical Resections of PosteroSuperior Liver Segments by Indocyanine Green Fluorescence: Intraoperative Navigation Based on Vascular Landmarks
    Aldrighetti, Luca
    Cipriani, Federica
    Fornoni, Gianluca
    Catena, Marco
    Ratti, Francesca
    CHIRURGIA, 2023, 118 (02) : 170 - 179
  • [10] Laparoscopic anatomical liver resection guided by real-time indocyanine green fluorescence imaging: experience and lessons learned from the initial series in a single center
    Xu, Yinzhe
    Chen, Mingyi
    Meng, Xiangfei
    Lu, Peng
    Wang, Xun
    Zhang, Wenwen
    Luo, Ying
    Duan, Weidong
    Lu, Shichun
    Wang, Hongguang
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2020, 34 (10): : 4683 - 4691