Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG

被引:10
|
作者
Iivanainen, Joonas [1 ]
Carter, Tony R. [1 ]
Trumbo, Michael C. S. [1 ]
McKay, Jim [2 ]
Taulu, Samu [3 ]
Wang, Jun [4 ,5 ]
Stephen, Julia M. [6 ]
Schwindt, Peter D. D. [1 ]
Borna, Amir [1 ]
机构
[1] Sandia Natl Labs, Albuquerque, NM 87185 USA
[2] Candoo Syst Inc, Port Coquitlam, BC, Canada
[3] Univ Washington, Seattle, WA USA
[4] Univ Texas Austin, Dept Speech Language & Hearing Sci, Austin, TX USA
[5] Univ Texas Austin, Dept Neurol, Austin, TX USA
[6] Mind Res Network, Lovelace Biomed Res Inst, Albuquerque, NM 87106 USA
关键词
magnetoencephalography; optically pumped magnetometer; classification; decoding; brain-computer interface; auditory cortex; ATOMIC MAGNETOMETER; PERFORMANCE; MAGNETOENCEPHALOGRAPHY;
D O I
10.1088/1741-2552/acfcd9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Optically pumped magnetometers (OPMs) are emerging as a near-room-temperature alternative to superconducting quantum interference devices (SQUIDs) for magnetoencephalography (MEG). In contrast to SQUIDs, OPMs can be placed in a close proximity to subject's scalp potentially increasing the signal-to-noise ratio and spatial resolution of MEG. However, experimental demonstrations of these suggested benefits are still scarce. Here, to compare a 24-channel OPM-MEG system to a commercial whole-head SQUID system in a data-driven way, we quantified their performance in classifying single-trial evoked responses. Approach. We measured evoked responses to three auditory tones in six participants using both OPM- and SQUID-MEG systems. We performed pairwise temporal classification of the single-trial responses with linear discriminant analysis as well as multiclass classification with both EEGNet convolutional neural network and xDAWN decoding. Main results. OPMs provided higher classification accuracies than SQUIDs having a similar coverage of the left hemisphere of the participant. However, the SQUID sensors covering the whole helmet had classification scores larger than those of OPMs for two of the tone pairs, demonstrating the benefits of a whole-head measurement. Significance. The results demonstrate that the current OPM-MEG system provides high-quality data about the brain with room for improvement for high bandwidth non-invasive brain-computer interfacing.
引用
收藏
页数:12
相关论文
共 26 条
  • [21] Classification of EEG-based single-trial motor imagery tasks using a B-CSP method for BCI
    Tang, Zhi-chuan
    Li, Chao
    Wu, Jian-feng
    Liu, Peng-cheng
    Cheng, Shi-wei
    FRONTIERS OF INFORMATION TECHNOLOGY & ELECTRONIC ENGINEERING, 2019, 20 (08) : 1087 - 1098
  • [22] Response to the first stimulus determines reduced auditory evoked response suppression in schizophrenia: single trials analysis using MEG
    Blumenfeld, LD
    Clementz, BA
    CLINICAL NEUROPHYSIOLOGY, 2001, 112 (09) : 1650 - 1659
  • [23] Single-trial EEG classification of motor imagery using deep convolutional neural networks
    Tang, Zhichuan
    Li, Chao
    Sun, Shouqian
    OPTIK, 2017, 130 : 11 - 18
  • [24] Single-trial classification of EEG in a visual object task using ICA and machine learning
    Stewart, Andrew X.
    Nuthmann, Antje
    Sanguinetti, Guido
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 228 : 1 - 14
  • [25] Massively parallel classification of single-trial EEG signals using a min-max modular neural network
    Lu, BL
    Shin, JH
    Ichikawa, M
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (03) : 551 - 558
  • [26] Classification of EEG-based single-trial motor imagery tasks using a B-CSP method for BCI
    Zhi-chuan Tang
    Chao Li
    Jian-feng Wu
    Peng-cheng Liu
    Shi-wei Cheng
    Frontiers of Information Technology & Electronic Engineering, 2019, 20 : 1087 - 1098