Temperature changes in the pulp chamber and bleaching gel during tooth bleaching assisted by diode laser (445 nm) using different power settings

被引:6
作者
Papadopoulou, Aggeliki [1 ]
Dionysopoulos, Dimitrios [1 ]
Strakas, Dimitrios [1 ]
Kouros, Pantelis [1 ]
Kolokitha, Olga-Elpis [2 ]
Tolidis, Kosmas [1 ]
机构
[1] Aristotle Univ Thessaloniki, Sch Hlth Sci, Fac Dent, Dept Operat Dent, Thessaloniki 54124, Greece
[2] Aristotle Univ Thessaloniki, Sch Hlth Sci, Fac Dent, Dept Orthodont, Thessaloniki 54124, Greece
关键词
Average power; Bleaching gel; Diode laser; Intrapulpal temperature rise; Pulp health; Tooth bleaching; INTRAPULPAL TEMPERATURE; THERMAL-INJURY; HEAT; RISE; TEETH; LIGHT;
D O I
10.1007/s10103-023-03863-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this in vitro study was to investigate the safety of using blue diode laser (445 nm) for tooth bleaching with regard to intrapulpal temperature increase operating at different average power and time settings. Fifty human mandibular incisors (n = 10) were used for evaluating temperature rise inside the pulp chamber and in the bleaching gel during laser-assisted tooth bleaching. The change in temperature was recorded using K thermocouples for the five experimental groups (without laser, 0.5, 1, 1.5 and 2 W) at each point of time (0, 10, 20, 30, 40, 50 and 60 s). As the average power of the diode laser increases, the temperature inside the pulp chamber also increases and that of the bleaching gel was significantly higher in all the experimental groups (p < 0.05). However, the intrapulpal temperature rise was below the threshold for irreversible thermal damage of the pulp (5.6 degrees C). Average power of a diode laser (445 nm) ranging between 0.5-2 W and irradiation time between 10-60 s should be considered safe regarding the pulp health when a red-colored bleaching gel is used. Clinical studies should confirm the safety and effectiveness of such tooth bleaching treatments. The outcomes of the present study could be a useful guide for dental clinicians, who utilize diode lasers (445 nm) for in-office tooth bleaching treatments in order to select appropriate power parameters and duration of laser irradiation without jeopardizing the safety of the pulp.
引用
收藏
页数:9
相关论文
共 35 条
[1]  
Abbot CH., 1918, J Allied Dent Society, V13, P259
[2]   The effect of bleaching gel and (940nm and 980nm) diode lasers photoactivation on intrapulpal temperature and teeth whitening efficiency [J].
Al-Karadaghi, Tamara S. ;
Al-Saedi, Asmaa A. ;
Al-Maliky, Mohammed A. ;
Mahmood, Ali S. .
AUSTRALIAN ENDODONTIC JOURNAL, 2016, 42 (03) :112-118
[3]   Clinical and histological evaluation of thermal injury thresholds in human teeth: A preliminary study [J].
Baldissara, P ;
Catapano, S ;
Scotti, R .
JOURNAL OF ORAL REHABILITATION, 1997, 24 (11) :791-801
[4]  
BOULNOIS J-L, 1986, Lasers in Medical Science, V1, P47, DOI 10.1007/BF02030737
[5]   External bleaching therapy with activation by heat, light or laser - A systematic review [J].
Buchalla, Wolfgang ;
Attin, Thomas .
DENTAL MATERIALS, 2007, 23 (05) :586-596
[6]   Bleaching effectiveness, hydrogen peroxide diffusion, and cytotoxicity of a chemically activated bleaching gel [J].
de Oliveira Duque, Carla Caroline ;
Soares, Diana Gabriela ;
Basso, Fernanda Goncalves ;
Hebling, Josimeri ;
de Souza Costa, Carlos Alberto .
CLINICAL ORAL INVESTIGATIONS, 2014, 18 (06) :1631-1637
[7]   Lasers in dentistry - Separating science from hype [J].
Dederick, DN ;
Bushick, RD .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2004, 135 (02) :204-212
[8]   Spectrophotometric analysis of the effectiveness of a novel in-office laser-assisted tooth bleaching method using Er, Cr:YSGG laser [J].
Dionysopoulos, Dimitrios ;
Strakas, Dimitrios ;
Tolidis, Kosmas ;
Tsitrou, Effrosyni ;
Koumpia, Effimia ;
Koliniotou-Koumpia, Eugenia .
LASERS IN MEDICAL SCIENCE, 2017, 32 (08) :1811-1818
[9]   The influence of a novel in-office tooth whitening procedure using an Er,Cr:YSGG laser on enamel surface morphology [J].
Dionysopoulos, Dimitrios ;
Strakas, Dimitrios ;
Koliniotou-Koumpia, Eugenia .
LASERS IN SURGERY AND MEDICINE, 2015, 47 (06) :503-511
[10]   Heat shock induces the synthesis of the inflammatory mediator leukotriene B4 in human pulp cells [J].
Eberhard, J ;
Zahl, A ;
Dommisch, H ;
Winter, J ;
Acil, Y ;
Jepsen, S .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (12) :882-888