A Graphene-Metasurface-Inspired Optical Sensor for the Heavy Metals Detection for Efficient and Rapid Water Treatment

被引:33
作者
Almawgani, Abdulkarem H. M. [1 ]
Surve, Jaymit [2 ]
Parmar, Tanvirjah [3 ]
Armghan, Ammar [4 ]
Aliqab, Khaled [4 ]
Ali, Ghassan Ahmed [5 ]
Patel, Shobhit K. K. [6 ]
机构
[1] Najran Univ, Coll Engn, Elect Engn Dept, Najran 61441, Saudi Arabia
[2] Marwadi Univ, Dept Elect Engn, Rajkot 360003, Guajrat, India
[3] Marwadi Univ, Dept Microbiol, Rajkot 360003, Guajrat, India
[4] Jouf Univ, Coll Engn, Dept Elect Engn, Sakaka 72388, Saudi Arabia
[5] Najran Univ, Coll Comp Sci, Informat Syst Dept, Najran 61441, Saudi Arabia
[6] Marwadi Univ, Dept Comp Engn, Rajkot 360003, Guajrat, India
关键词
heavy metals detection; Cu2+; Mg2+; graphene; tuning; optical sensors; ELECTROMAGNETICALLY INDUCED TRANSPARENCY; METAMATERIAL; BIOSENSORS; ABSORBER; REMOVAL; CRYSTAL; CANCER;
D O I
10.3390/photonics10010056
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Heavy metal ion contamination of water supplies has significantly increased during the last century due to advances in industry and technology. Therefore, a lot of effort was put into developing chemical and physical methods for detecting and tracking the presence of these potentially harmful solutions. Despite their comparatively high sensitivity and low detection limits, these methods are hindered by complex instrumentation and tedious, expensive, and difficult chemical processes. Therefore, in this study, we present a straightforward and effective sensing method based on the graphene metasurface for detecting several classes of heavy metal ions. A graphene-metasurface-inspired optical sensor with a glass substrate is developed that can detect Cu2+ and Mg2+ with a sensitivity of 113.92 GHz/RIU and 113.9 GHz/RIU, respectively. In addition to that, the linear fitting curve for both the metal ions is established, and R-2 score of 0.9997 and 0.9982 is achieved, respectively. Furthermore, the lowest value of the figure of merit (FOM) of 2.98 RIU-1 and the maximum Quality factor (Q factor) of 11.22 is obtained. The proposed structure also exhibited a low detection limit as well as a resolution of 0.52 RIU and 78.14 THz, respectively. As a result of these findings, a simple and accurate tool for detecting water contamination with heavy metals and aqueous solutions with relatively high performance is developed.
引用
收藏
页数:15
相关论文
共 35 条
  • [1] Highly sensitive Au-Fe2O3-Au and Fe2O3-Au-Fe2O3 biosensors utilizing strong surface plasmon resonance
    Ahmed, Ashour M.
    Shaban, Mohamed
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 2020, 126 (04):
  • [2] Copper removal from industrial wastewater: A comprehensive review
    Al-Saydeh, Sajeda A.
    El-Naas, Muftah H.
    Zaidi, Syed J.
    [J]. JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2017, 56 : 35 - 44
  • [3] Ultra-stable D-shaped Optical Fiber Refractive Index Sensor with Graphene-Gold Deposited Platform
    An, Guowen
    Li, Shuguang
    Cheng, Tonglei
    Yan, Xin
    Zhang, Xuenan
    Zhou, Xue
    Yuan, Zhenyu
    [J]. PLASMONICS, 2019, 14 (01) : 155 - 163
  • [4] [Anonymous], COMSOL Multiphysics
  • [5] Bent S, 1995, Gesundheitswesen, V57, P667
  • [6] Electrochemical biosensors for pathogen detection
    Cesewski, Ellen
    Johnson, Blake N.
    [J]. BIOSENSORS & BIOELECTRONICS, 2020, 159
  • [7] From collection to discharge: physical, chemical, and biological analyses for fish farm water quality monitoring
    de Souza, Jessica Pereira
    Vivian Sposito, Juliana Caroline
    Crispim, Bruno do Amaral
    da Silva, Fabiane Gomes
    Pires de Oliveira, Kelly Mari
    Kummrow, Fabio
    do Nascimento, Valter Aragao
    Montagner, Cassiana Carolina
    Viana, Lucilene Finoto
    Jut Solorzano, Julio Cesar
    Barufatti, Alexeia
    [J]. ECOTOXICOLOGY, 2019, 28 (01) : 13 - 25
  • [8] Graphene deposited liquid crystal and thermal sensitivity using photonic crystals
    Elsayed, Hussein A.
    Sayed, Fatma A.
    Aly, Arafa H.
    [J]. PHYSICA SCRIPTA, 2021, 96 (03)
  • [9] A Route to Terahertz Metamaterial Biosensor Integrated with Microfluidics for Liver Cancer Biomarker Testing in Early Stage
    Geng, Zhaoxin
    Zhang, Xiong
    Fan, Zhiyuan
    Lv, Xiaoqing
    Chen, Hongda
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [10] Electromagnetically induced transparency in planar complementary metamaterial for refractive index sensing applications
    He, X-J
    Wang, L.
    Wang, J-M
    Tian, X-H
    Jiang, J-X
    Geng, Z-X
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2013, 46 (36)