Image quality models for 2D and 3D x-ray imaging systems: A perspective vignette

被引:2
作者
Siewerdsen, Jeffrey H. H. [1 ,2 ,3 ,4 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, 1400 Pressler, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Neurosurg, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Inst Data Sci Oncol, Surg Data Sci, Houston, TX 77030 USA
关键词
cascaded systems analysis; cone-beam CT; dual-energy imaging; flat-panel detectors; image quality; image reconstruction; imaging task; noise-power spectrum; spatial resolution; tomosynthesis; CONE-BEAM CT; NOISE-POWER SPECTRUM; FLAT-PANEL IMAGERS; DETECTIVE QUANTUM EFFICIENCY; SPATIAL-RESOLUTION; OPTIMIZATION; SIGNAL; PROPAGATION; PERFORMANCE; SCANNER;
D O I
10.1002/mp.16051
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Image quality models based on cascaded systems analysis and task-based imaging performance were an important aspect of the emergence of 2D and 3D digital x-ray systems over the last 25 years. This perspective vignette offers cursory review of such developments and personal insights that may not be obvious within previously published scientific literature. The vignette traces such models to the mid-1990s, when flat-panel x-ray detectors were emerging as a new base technology for digital radiography and benefited from the rigorous, objective characterization of imaging performance gained from such models. The connection of models for spatial resolution and noise to spatial-frequency-dependent descriptors of imaging task provided a useful framework for system optimization that helped to accelerate the development of new technologies to first clinical use. Extension of the models to new technologies and applications is also described, including dual-energy imaging, photon-counting detectors, phase contrast imaging, tomosynthesis, cone-beam CT, 3D image reconstruction, and image registration.
引用
收藏
页码:109 / 116
页数:8
相关论文
共 35 条
  • [11] Analysis of Fourier-domain task-based detectability index in tomosynthesis and cone-beam CT in relation to human observer performance
    Gang, Grace J.
    Lee, Junghoon
    Stayman, J. Webster
    Tward, Daniel J.
    Zbijewski, W.
    Prince, Jerry L.
    Siewerdsen, Jeffrey H.
    [J]. MEDICAL PHYSICS, 2011, 38 (04) : 1754 - 1768
  • [12] A semiempirical linear model of indirect, flat-panel x-ray detectors
    Huang, Shih-Ying
    Yang, Kai
    Abbey, Craig K.
    Boone, John M.
    [J]. MEDICAL PHYSICS, 2012, 39 (04) : 2108 - 2118
  • [13] A Statistical Model for Rigid Image Registration Performance: The Influence of Soft-Tissue Deformation as a Confounding Noise Source
    Ketcha, Michael D.
    De Silva, Tharindu
    Han, Runze
    Uneri, Ali
    Vogt, Sebastian
    Kleinszig, Gerhard
    Siewerdsen, Jeffrey H.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (09) : 2016 - 2027
  • [14] Effects of Image Quality on the Fundamental Limits of Image Registration Accuracy
    Ketcha, Michael D.
    De Silva, Tharindu
    Han, Runze
    Uneri, Ali
    Goerres, Joseph
    Jacobson, Matthew W.
    Vogt, Sebastian
    Kleinszig, Gerhard
    Siewerdsen, Jeffrey H.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (10) : 1997 - 2009
  • [15] THE NOISE POWER SPECTRUM OF CT IMAGES
    KIJEWSKI, MF
    JUDY, PF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (05) : 565 - 575
  • [16] Fundamental relationship between the noise properties of grating-based differential phase contrast CT and absorption CT: Theoretical framework using a cascaded system model and experimental validation
    Li, Ke
    Bevins, Nicholas
    Zambelli, Joseph
    Chen, Guang-Hong
    [J]. MEDICAL PHYSICS, 2013, 40 (02)
  • [17] Image quality of scintillator based X-ray electronic imagers
    Moy, JP
    [J]. PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 187 - 194
  • [18] Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging
    Prakash, P.
    Zbijewski, W.
    Gang, G. J.
    Ding, Y.
    Stayman, J. W.
    Yorkston, J.
    Carrino, J. A.
    Siewerdsen, J. H.
    [J]. MEDICAL PHYSICS, 2011, 38 (10) : 5612 - 5629
  • [19] Optimization of dual-energy imaging systems using generalized NEQ and imaging task
    Richard, S.
    Siewerdsen, J. H.
    [J]. MEDICAL PHYSICS, 2007, 34 (01) : 127 - 139
  • [20] Cone-beam CT with a flat-panel detector: From image science to image-guided surgery
    Siewerdsen, Jeffrey H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S241 - S250