Intraoperative electron beam intercomparison of 6 sites using mailed thermoluminescence dosimetry: Absolute dose and energy

被引:0
|
作者
Dries, Wim [1 ]
Petoukhova, Anna [2 ,7 ]
Hertsens, Nicolas [3 ]
Stevens, Piet [4 ]
Jarbinet, Valerie [5 ]
Bimmel-Nagel, Cathryn Huibregtse [1 ]
Weterings, Jan [1 ]
van Wingerden, Ko [2 ]
Bauwens, Charlotte [3 ]
Vanreusel, Verdi [4 ]
Simon, Stephane [6 ]
机构
[1] Catharina Hosp, Eindhoven, Netherlands
[2] Haaglanden Med Ctr, Dept Med Phys, Leidschendam, Netherlands
[3] AZ Groeninge, Dept Radiotherapy, Kortrijk, Belgium
[4] GZA Hosp, Antwerp, Belgium
[5] CHU Tivoli, La Louviere, Belgium
[6] Jules Bordet Inst, Brussels, Belgium
[7] Haaglanden Med Ctr, Dept Med Phys, POB 432, NL-2501 CK The Hague, Netherlands
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2024年 / 119卷
关键词
IORT; Electron IORT (IOERT); Intraoperative electron beam dosimetry; Intercomparison; Thermoluminescence dosimetry; Absolute dose and energy; TASK FORCE/ACROP RECOMMENDATIONS; ESTRO/ACROP IORT RECOMMENDATIONS; RADIATION-THERAPY; AUDITS; TLD;
D O I
10.1016/j.ejmp.2024.103302
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In 2018, the Netherlands Commission on Radiation Dosimetry subcommittee on IORT initiated a limited intercomparison of electron IORT (IOERT) in Belgium and The Netherlands. The participating institutions have enough variability in age, type of equipment, and in dose calibration protocols. Methods: In this study, three types of IOERT-dedicated mobile accelerators were represented: Mobetron 2000, LIAC HWL and LIAC. Mobetron produces electron beams with energies of 6, 9 and 12 MeV, while LIAC HWL and LIAC can deliver 6, 8, 10 and 12 MeV electron beams. For all energies, the reference beam (10 cm diameter, 0 incidence) and 5 cm diameter beams were measured, as these smaller beams are used more frequently in clinic. The mailed TLD service from the Radiation Dosimetry Services (RDS, Houston, USA) has been used. Following RDS' standard procedures, each beam was irradiated to 300 cGy at d(max )with TLDs around d(max) and around depth of 50 % dose (R50). Absolute dose at 100 % and beam energy, expressed as R50, could be verified in this way. Results: All absolute doses and energies under reference conditions were well within RDS-stated uncertainties: dose deviations were <5 % and deviations in R50 were <5 mm. For the small 5 cm beams, all results were also within acceptance levels except one absolute dose value. Deviations were not significantly dependent on manufacturer, energy, diameter and calibration protocol. Conclusions: All absolute dose values, except one of a non-reference beam, and all energy values were well within the measurement accuracy of RDS TLDs.
引用
收藏
页数:7
相关论文
共 11 条
  • [1] Cherenkov emission dosimetry for electron beam radiotherapy: a Monte Carlo feasibility study of absolute dose prediction
    Zlateva, Y.
    El Naqa, I.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 828 - 831
  • [2] Is Electron Beam Intraoperative Radiotherapy (ELIOT) Safe in Pregnant Women with Early Breast Cancer? In Vivo Dosimetry to Assess Fetal Dose
    Galimberti, Viviana
    Ciocca, Mario
    Leonardi, Maria Cristina
    Zanagnolo, Vanna
    Paola, Baratella
    Manuela, Sargenti
    Sahium, Rafaela Cecilio
    Lazzari, Roberta
    Gentilini, Oreste
    Peccatori, Fedro
    Veronesi, Umberto
    Orecchia, Roberto
    ANNALS OF SURGICAL ONCOLOGY, 2009, 16 (01) : 100 - 105
  • [3] In vivo Dosimetry for Dose Verification of Total Skin Electron Beam Therapy Using Gafchromic® EBT3 Film Dosimetry
    Baba, Misba Hamid
    Singh, Benoy Kumar
    Wani, Shaqul Qamar
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (04) : 362 - 366
  • [4] Intraoperative radiation therapy using electron-beam and high-dose-rate brachytherapy
    Nag, S
    MartinezMonge, R
    Gupta, N
    CANCER JOURNAL - FRANCE, 1997, 10 (02): : 94 - 101
  • [5] Measurement of entrance skin dose and absorbed dose to different organs in dual-energy X-ray absorptiometry scans using thermoluminescence dosimetry
    Rezazadeh, Fatemeh
    Negarestani, Ali
    Sina, Sedigheh
    Farajzadeh, Ebrahim
    Karari, Behnaz
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (02) : 116 - 123
  • [6] Clinical results of entrance dose in vivo dosimetry for high energy photons in external beam radiotherapy using MOSFETs
    Morton, J. P.
    Bhat, M.
    Williams, T.
    Kovendy, A.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (04) : 252 - 259
  • [7] High dose-per-pulse electron beam dosimetry: Commissioning of the Oriatron eRT6 prototype linear accelerator for preclinical use
    Jaccard, Maud
    Duran, Maria Teresa
    Petersson, Kristoffer
    Germond, Jean-Francois
    Liger, Philippe
    Vozenin, Marie-Catherine
    Bourhis, Jean
    Bochud, Francois
    Bailat, Claude
    MEDICAL PHYSICS, 2018, 45 (02) : 863 - 874
  • [8] Measurement of Total Energy of Pulsed Electron Beam From a Plasma Focus Device Using Dosimetry of Bremsstrahlung X-Ray
    Radaie, Masoud
    Bidabadi, Babak Shirani
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2019, 47 (05) : 2675 - 2679
  • [9] Assessment of out-of-field radiation doses for high dose per pulse intraoperative electron beam radiotherapy using TLD-100
    Aghdam, Seyed Rashid Hosseini
    Aghamiri, Seyed Mahmoud Reza
    Siavashpour, Zahra
    Malekie, Shahryar
    Dashtipoor, Mohammad Reza
    RADIATION PHYSICS AND CHEMISTRY, 2023, 204
  • [10] Real-time in vivo dosimetry using micro-MOSFET detectors during intraoperative electron beam radiation therapy in early-stage breast cancer
    Ciocca, M
    Piazzi, V
    Lazzari, R
    Vavassori, A
    Luini, A
    Veronesi, P
    Galimberti, V
    Intra, M
    Guido, A
    Tosi, G
    Veronesi, U
    Orecchia, R
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 (02) : 213 - 216