Accuracy and reproducibility of two-dimensional computed tomography-based positioning of femoral component rotational alignment in preoperative planning for total knee arthroplasty

被引:1
作者
Liu, Kun [1 ]
Liu, Yuandong [1 ]
Fan, Zongqing [1 ]
Fu, Donglin [1 ]
机构
[1] Anhui Med Univ, Fuyang Peoples Hosp, Fuyang 236000, Anhui, Peoples R China
关键词
Total knee arthroplasty; Preoperative planning; Rotational alignment; Posterior condylar angle; Two-dimensional(2D) measurement; Three-dimensional(3D) measurement; SURGICAL EPICONDYLAR AXIS; DISTAL FEMUR; TRANSEPICONDYLAR AXIS; FLEXION; CT; ORIENTATION; LANDMARKS; ANGLE; LINE;
D O I
10.1186/s13018-023-04466-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Poor rotation of the femoral component in total knee arthroplasty (TKA) can result in various postoperative complications, underscoring the critical importance of preoperative planning. Purpose: To improve the accuracy of femoral component positioning during TKA, this study compared the accuracy and repeatability of different two-dimensional (2D) computed tomography (CT) measurement methods for measuring the posterior condylar angle (PCA) in preoperative TKA planning. Methods: A retrospective analysis was conducted on 75 patients (150 knees) who underwent bilateral lower extremity computed tomography angiography (CTA) at Fuyang People's Hospital from January 2021 to July 2021. Three different methods were used to measure the PCA based on 2D CT images (axial CT slices) and three-dimensional(3D) models (femoral models reconstructed from CT data) in this study. Method 1: Single-plane 2D CT measurement, measuring PCA in the most obvious single-plane CT slice of the surgical transepicondylar axis (sTEA); Method 2: multi-plane 2D CT measurement, identifying and locating anatomical landmarks in multiple 2D CT slices and measuring PCA; Method 3: 3D model measurement, measuring PCA in the reconstructed femur 3D model. Compare the differences in PCA measurements between the three measurement methods. A positive PCA measurement was recorded when the sTEA was externally rotated relative to the posterior condylar line (PCL). Any difference exceeding 3 degrees between the PCA measurement in the 2D CT and the PCA reference value in the 3D model was classified as an outlier. The intraclass correlation coefficient (ICC) and Bland-Altman method were utilized to assess the intra- and inter-observer reproducibility of the three measurement methods. Results: The PCA measurement in the single-plane 2D CT was 1.91 +/- 1.94 degrees, with a measurement error of - 1.22 +/- 1.32 degrees and 12.7% of outlier values. In the multi-plane 2D CT, the PCA measurement was 2.96 +/- 1.68 degrees, with a measurement error of -0.15 +/- 0.91 degrees and 6.0% of outlier values. The PCA measurement in the 3D model was 3.12 +/- 1.69 degrees. The PCA measurement in single-plane 2D CT was notably smaller than that in multi-plane 2D CT and 3D models, with no significant difference between the latter two. The multi-plane 2D CT showed significantly lower measurement error and outlier values than the single-plane 2D CT. All three PCA measurement methods exhibited high reproducibility (ICC: 0.93 similar to 0.97). Conclusions: Using of multi-plane 2D CT for measuring PCA in preoperative planning of TKA has high reproducibility and accuracy, with fewer outlier values. We recommend preoperative measurement of PCA using muti-plane 2D CT to improve the accuracy of positioning the femoral component rotational alignment during surgery.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Accuracy of femoral rotational alignment in total knee arthroplasty using computer assisted navigation
    Restrepo, Camilo
    Hozacic, William J.
    Orozco, Fabio
    Parvizi, Javad
    COMPUTER AIDED SURGERY, 2008, 13 (03) : 167 - 172
  • [22] Accuracy of computer navigation in total knee arthroplasty: A prospective computed tomography-based study
    Hannan, Richard
    Free, Matthew
    Arora, Varun
    Harle, Robin
    Harvie, Paul
    MEDICAL ENGINEERING & PHYSICS, 2020, 79 : 52 - 59
  • [23] Asymmetric Implant Design for Posterolateral Overhang of the Femoral Component in Total Knee Arthroplasty: A Retrospective Computed Tomography-Based Study
    Hirakawa, Masashi
    Miyazaki, Masashi
    Nagashima, Yu
    Akase, Hiroya
    Matsuda, Shogo
    Kaku, Nobuhiro
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [24] Accuracy of anatomical references used for rotational alignment of tibial component in total knee arthroplasty
    Namık Şahin
    Teoman Atıcı
    Alpaslan Öztürk
    Güven Özkaya
    Yüksel Özkan
    Bülent Avcu
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 565 - 570
  • [25] Intraoperative Measurements of Femoral Anterior Tangent (FAT) Line for Determining the Rotational Alignment of Femoral Component of Total Knee Arthroplasty
    Watanabe, Hiroki
    Gejo, Ryuichi
    Tokunaga, Ayano
    Hirano, Norikazu
    Kimura, Tomoatsu
    JOURNAL OF ARTHROPLASTY, 2013, 28 (10) : 1757 - 1759
  • [26] How to assess femoral and tibial component rotation after total knee arthroplasty with computed tomography: a systematic review
    De Valk, Eduard J.
    Noorduyn, Julia C. A.
    Mutsaerts, Eduard L. A. R.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (11) : 3517 - 3528
  • [27] Functional Outcome and Rotational Alignment of Femoral Component in Unnavigated Total Knee Arthroplasty
    Madhukar, Vignesh D.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (04): : 476 - 487
  • [28] Rotational alignment of femoral component with different methods in total knee arthroplasty: a randomized, controlled trial
    Lee, Joon Kyu
    Lee, Sahnghoon
    Chun, Sae Hyung
    Kim, Ki Tae
    Lee, Myung Chul
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [29] Accuracy of Computed Tomography-Based Navigation-Assisted Total Knee Arthroplasty: Outlier Analysis
    Miyasaka, Teruyuki
    Kurosaka, Daisaburo
    Saito, Mitsuru
    Omori, Toshiyuki
    Ikeda, Ryo
    Marumo, Keishi
    JOURNAL OF ARTHROPLASTY, 2017, 32 (01) : 47 - 52
  • [30] Preoperative tibiofemoral rotational alignment is a risk factor for component rotational mismatch in total knee arthroplasty
    Kawaguchi, Kohei
    Inui, Hiroshi
    Taketomi, Shuji
    Yamagami, Ryota
    Kono, Kenichi
    Sameshima, Shin
    Kage, Tomofumi
    Tanaka, Sakae
    KNEE, 2021, 29 : 448 - 456