Data analytics improves the diagnostic accuracy of serum free light chain results for detecting monoclonal gammopathy

被引:3
作者
Treger, Rebecca S. [1 ]
Mathias, Patrick C. [1 ]
Cowan, Andrew J. [2 ,3 ]
Green, Damian [2 ,3 ]
Hutchinson, Kathleen [1 ]
Bryan, Andrew [1 ]
Chaudhary, Anu [1 ]
Fink, Susan L. [1 ]
Wener, Mark H. [1 ,4 ]
Morishima, Chihiro [1 ]
机构
[1] Univ Washington, Dept Lab Med & Pathol, Seattle, WA 98195 USA
[2] Univ Washington, Div Med Oncol, Seattle, WA USA
[3] Fred Hutch Canc Ctr, Clin Res Div, Seattle, WA USA
[4] Univ Washington, Dept Med, Div Rheumatol, Seattle, WA 98195 USA
关键词
serum free light chain assay; Freelite; reference interval; kappa:lambda ratio; multiple myeloma; monoclonal gammopathy; CHRONIC KIDNEY-DISEASE; REFERENCE INTERVALS; KAPPA/LAMBDA RATIO; MULTIPLE-MYELOMA; ASSAY; ELECTROPHORESIS; AMYLOIDOSIS; CRITERIA; KAPPA; RACE;
D O I
10.1093/ajcp/aqad137
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Objectives: To evaluate the real-world performance and reference intervals of the Binding Site Freelite serum free light chain (SFLC) assay (Thermo Fisher Scientific), a global standard for diagnosis, prognostication, and response assessment for monoclonal gammopathies.Methods: An informatics-based approach was used to retrospectively evaluate concordance between SFLC and the orthogonal Sebia HYDRASYS immunofixation assay results in a large clinical data set consecutively reported between 2010 and 2020.Results: Among patients with monoclonal-negative results by both SFLC and Sebia HYDRASYS immunofixation assays, 25% (1226/5057) had kappa/lambda ratios (KLRs) outside the manufacturer-defined and International Myeloma Working Group-cited normal reference interval of 0.26 to 1.65. These results were consistent over the study period and were not affected by sex, age, impaired kidney function, or assay antisera lot variation. Assay drift, in addition to other potential factors, affected the KLR distribution. Using International Statistical Classification of Diseases (ICD) codes, kidney function data, and the central 95% of KLR values generated on the Optilite platform (Thermo Fisher Scientific), we derived a new reference interval of 0.67 to 2.13, reducing the KLR false-positive rate to 8%. However, normal KLR persisted among 16% (14/85) of samples with free lambda chains by immunofixation, warranting caution during interpretation.Conclusions: Our analysis indicated that revision of Freelite SFLC reference intervals improves assay interpretation and should prompt reconsideration of Freelite reference intervals worldwide.
引用
收藏
页码:216 / 231
页数:16
相关论文
共 56 条
[51]  
RStudio Team, 2020, RSTUDIO INTEGRATED D
[52]   Calculating estimated glomerular filtration rate without the race correction factor: Observations at a large academic medical system [J].
Shi, Junyan ;
Lindo, G. Edwin ;
Baird, S. Geoffrey ;
Young, Bessie ;
Ryan, Michael ;
Jefferson, J. Ashley ;
Mehrotra, Rajnish ;
Mathias, C. Patrick ;
Hoofnagle, N. Andrew .
CLINICA CHIMICA ACTA, 2021, 520 :16-22
[53]  
Singh G, 2016, AM J CLIN PATHOL, V146, P207, DOI [10.1093/AJCP/AQW099, 10.1093/ajcp/aqw099]
[54]   Measurement of free light chains with assays based on monoclonal antibodies [J].
te Velthuis, Henk ;
Drayson, Mark ;
Campbell, John P. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (06) :1005-1014
[55]   Racial disparities in incidence and outcome in multiple myeloma: a population-based study [J].
Waxman, Adam J. ;
Mink, Pamela J. ;
Devesa, Susan S. ;
Anderson, William F. ;
Weiss, Brendan M. ;
Kristinsson, Sigurdur Y. ;
McGlynn, Katherine A. ;
Landgren, Ola .
BLOOD, 2010, 116 (25) :5501-5506
[56]  
Wickham H., 2019, J OPEN SOURCE SOFTWA, V4, P1686, DOI [DOI 10.21105/JOSS.01686, 10.21105/joss.01686]