Experimental and numerical investigation of a rectangular finned-tube latent heat storage unit for Carnot battery

被引:7
|
作者
Zheng, Siyu [1 ]
Li, Songrui [1 ]
Li, Meng [1 ]
Dai, Rui [1 ]
Wei, Mingshan [1 ]
Tian, Ran [1 ]
机构
[1] Beijing Inst Technol, Sch Mech Engn, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Carnot battery system; Latent heat storage; Composite phase change material; Numerical simulation; Experimental research; THERMAL-ENERGY STORAGE; PHASE-CHANGE MATERIALS; CONDUCTIVITY ENHANCEMENT; COMPOSITE; SYSTEM; TECHNOLOGY; EXCHANGER; FINS; PART;
D O I
10.1016/j.est.2023.108092
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Latent heat storage technology has a great potential in Carnot battery systems, and its thermal performance directly affects the system performance. In this paper, a rectangular phase change heat storage unit with finned tube structure is designed and manufactured, and polyethylene wax/expanded graphite is adopted as the composite phase change material. The thermophysical properties of the polyethylene wax are characterized by experiments first, and then the heat transfer performance of the unit is investigated through varying inlet mass flow rates and inlet temperature on the test rig. Meanwhile, the detailed evolution of the phase change process is visualized and obtained by corresponding numerical simulations. Furthermore, the effects and selection principle of fin number, thickness, and material on the melting process are clarified by numerical simulations. Results shows that the influence of the inlet temperature is more significant than the mass flow rate on the melting/ solidification time, however, changing the inlet temperature and mass flow rate has little effect on melting/ solidifying the last 10 % of PCM. Heat conduction dominated the heat transfer process due to the high viscosity of polyethylene wax, inducing little stratification of the temperature distribution in the regions bounded by fins. The regions close to the corners and sidewalls are the primary factors delaying melting/solidification rate. Increasing fin number and thickness can effectively decrease the melting/solidification time at the expense of the heat storage capacity. Compared to selecting only high thermal conductivity fin materials, adopting fins with high thermal conductivity, low density, and low specific heat is a better approach for achieving higher heat storage capacity and shorter melting time. The present study explores candidate materials for medium-low temperature latent heat storage and potential applications of traditional finned-tube heat exchangers in medium-low temperature latent heat storage.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Numerical analysis of the performance enhancement of a latent heat storage shell and tube unit using finned tubes during melting and solidification
    Dekhil, Mohamed Amine
    Tala, Jules Voguelin Simo
    Bulliard-Sauret, Odin
    Bougeard, Daniel
    APPLIED THERMAL ENGINEERING, 2021, 192
  • [42] NUMERICAL-ANALYSIS IN THE SOLIDIFICATION PROCESS .1. LATENT-HEAT STORAGE IN A UNIT WITH A CIRCULAR-FINNED TUBE
    IMURA, H
    YOSHIDA, M
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1986, 29 (258): : 4469 - 4470
  • [43] Experimental investigation of a novel solar air heater based on heat pipe vacuum tube collector integrated with finned-tube heat exchanger
    Sachdeva, Anshul
    Chandrashekara, M.
    Yadav, Avadhesh
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2023, 148 (20) : 10917 - 10936
  • [44] Numerical investigation of PCM melting using different tube configurations in a shell and tube latent heat thermal storage unit
    Mahdi, Mustafa S.
    Mahood, Hameed B.
    Alammar, Ahmed A.
    Khadom, Anees A.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 25
  • [45] Experimental study of frost growth characteristics on surface of finned-tube heat exchangers
    Zhang L.
    Guo X.
    Xue J.
    Huagong Xuebao/CIESC Journal, 2018, 69 : 186 - 192
  • [46] Heat transfer characteristics of a latent heat thermal energy storage unit with a finned tube (effects of fin configuration)
    Sasaguchi, Kengo
    Yoshida, Masamichi
    Nakashima, Shuji
    Heat Transfer - Japanese Research, 1990, 19 (01): : 11 - 27
  • [47] HEAT-TRANSFER CHARACTERISTICS OF A LATENT-HEAT STORAGE UNIT WITH A FINNED TUBE .2. NUMERICAL-ANALYSIS OF SOLIDIFICATION PROCESS
    SASAGUCHI, K
    IMURA, H
    FURUSHO, H
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1986, 29 (255): : 2986 - 2992
  • [48] Experimental comparative analysis of finned-tube PCM-heat exchangers? performance
    Herbinger, Florent
    Groulx, Dominic
    APPLIED THERMAL ENGINEERING, 2022, 211
  • [49] An experimental and computational study of approach air distribution for a finned-tube heat exchanger
    Yashar, David A.
    Domanski, Piotr A.
    Cho, Hong Hyun
    HVAC&R RESEARCH, 2011, 17 (01): : 76 - 85
  • [50] Experimental research on natural convection heat transfer performances of finned-tube radiators
    Li, FT
    Xiao, YR
    ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 482 - 487